Diagnosis and early detection of COPD using spirometry.
Open accessThe DOI matches its OpenAlex record; 80 of the 80 references it cites were found in a registry or an index.
Abstract
The standard respiratory function test for case detection of chronic obstructive pulmonary disease (COPD) is spirometry. The criterion for diagnosis defined in guidelines is based on the FEV1/FVC ratio forced expiratory ratio (FER) and its severity is based on forced expiratory volume in one second (FEV1) from measurements obtained during maximal forced expiratory manoeuvres. Spirometry is a safe and practical procedure, and when conducted by a trained operator using a spirometer that provides quality feedback, the majority of patients can be coached to provide acceptable and repeatable results. This allows potentially wide application of testing to improve recognition and diagnosis of COPD, such as for case finding in primary care. However, COPD remains substantially under diagnosed in primary care and a major reason for this is underuse of spirometry. The presence of symptoms is not a reliable indicator of disease and diagnosis is often delayed until more severe airflow obstruction is present. Early diagnosis is worthwhile, as it allows risk factors for COPD such as smoking to be addressed promptly and treatment optimised. Paradoxically, investigation of the patho-physiology in COPD has shown that extensive small airway disease exists before it is detectable with conventional spirometric indices, and methods to detect airway disease earlier using the flow-volume curve are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
PAUWELS, R. A., BUIST, A. S., CALVERLEY, P. M. A., JENKINS, C. R., & HURD, S. S. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.5.2101039 · Cited by 6,587
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945 · cited 1×
“This is explicitly acknowledged in the ATS/ERS statement on the interpretation of lung function (82), but has largely been ignored in practice because none of the measurements taken currently to reflect this concavity are robust enough.”
BackgroundSpirometric Reference Values from a Sample of the General U.S. Population
HANKINSON, J. L., ODENCRANTZ, J. R., & FEDAN, K. B. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.1.9712108 · Cited by 4,206 · cited 1×
“com debate on the use of a single fixed cut-off for FER to confirm the presence of airflow obstruction in COPD, because the lower limit of normal for FER decreases with age (25).”
BackgroundThe natural history of chronic airflow obstruction.
Fletcher, C., & Peto, R. (1977) · BMJ · doi:10.1136/bmj.1.6077.1645 · Cited by 2,370 · cited 1×
“There is a strong emphasis on smoking cessation in both NICE (39) and GOLD (15) guidelines as the intervention with the greatest capacity to influence the natural history of COPD (58).”
BackgroundBuist, A. S., McBurnie, M. A., Vollmer, W. M., Gillespie, S., Burney, P., Mannino, D. M., Menezes, A. M., Sullivan, S. D., Lee, T. A., Weiss, K. B., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61377-4 · Cited by 2,366
Chronic obstructive pulmonary disease in non-smokers
Salvi, S. S., & Barnes, P. J. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61303-9 · Cited by 1,368
Global Strategy for the Diagnosis, Management and Prevention of COPD: 2003 update
Fabbri, L. M., & Hurd, S. S. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00063703 · Cited by 1,277
Small-Airway Obstruction and Emphysema in Chronic Obstructive Pulmonary Disease
McDonough, J. E., Yuan, R., Suzuki, M., Seyednejad, N., Elliott, W. M., Sanchez, P. G., Wright, A. C., Gefter, W. B., Litzky, L., Coxson, H. O., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1106955 · Cited by 1,207
Cited by
Clinical Significance of Symptoms in Smokers with Preserved Pulmonary Function
Woodruff, P. G., Barr, R. G., Bleecker, E., Christenson, S. A., Couper, D., Curtis, J. L., Gouskova, N. A., Hansel, N. N., Hoffman, E. A., Kanner, R. E., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1505971 · Cited by 684
Willer, K., Fingerle, A. A., Noichl, W., De Marco, F., Frank, M., Urban, T., Schick, R., Gustschin, A., Gleich, B., Herzen, J., et al. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00146-1 · Cited by 171
Metadata
- Authors
- Johns, D. P., Walters, J. A., & Walters, E. H.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 2014-11-01
- Volume
- 6
- Issue
- 11
- Pages
- 1557-69
- OpenAlex
- W1763507289
- Cited by
- 169
- References
- 80
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.