Review of MRI-based measurements of pulse wave velocity: a biomarker of arterial stiffness.
Open accessThe DOI matches its OpenAlex record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Atherosclerosis is the leading cause of cardiovascular disease (CVD) in the Western world. In the early development of atherosclerosis, vessel walls remodel outwardly such that the vessel luminal diameter is minimally affected by early plaque development. Only in the late stages of the disease does the vessel lumen begin to narrow-leading to stenoses. As a result, angiographic techniques are not useful for diagnosing early atherosclerosis. Given the absence of stenoses in the early stages of atherosclerosis, CVD remains subclinical for decades. Thus, methods of diagnosing atherosclerosis early in the disease process are needed so that affected patients can receive the necessary interventions to prevent further disease progression. Pulse wave velocity (PWV) is a biomarker directly related to vessel stiffness that has the potential to provide information on early atherosclerotic disease burden. A number of clinical methods are available for evaluating global PWV, including applanation tonometry and ultrasound. However, these methods only provide a gross global measurement of PWV-from the carotid to femoral arteries-and may mitigate regional stiffness within the vasculature. Additionally, the distance measurements used in the PWV calculation with these methods can be highly inaccurate. Faster and more robust magnetic resonance imaging (MRI) sequences have facilitated increased interest in MRI-based PWV measurements. This review provides an overview of the state-of-the-art in MRI-based PWV measurements. In addition, both gold standard and clinical standard methods of computing PWV are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077 · cited 1×
“Also, obesity is a cause of operator bias in PWV measurements with applanation tonometry (18-20).”
BackgroundCompensatory Enlargement of Human Atherosclerotic Coronary Arteries
Glagov, S., Weisenberg, E., Zarins, C. K., Stankunavicius, R., & Kolettis, G. J. (1987) · New England Journal of Medicine · doi:10.1056/nejm198705283162204 · Cited by 3,623 · cited 1×
“PWV is potentially a very strong early biomarker of atherosclerosis, given that arterial stiffness first increases without changes in vascular geometry—via the Glagov phenomenon— due to outward remodeling of atherosclerotic plaques (3) (Figure 1).”
BackgroundStein, J. H., Korcarz, C. E., Hurst, R. T., Lonn, E., Kendall, C. B., Mohler, E. R., Najjar, S. S., Rembold, C. M., & Post, W. S. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.11.011 · Cited by 2,429 · cited 1×
“However, they may also be user dependent and intimal thickening can occur in the absence of atherosclerosis (23).”
BackgroundIntimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging.
Pignoli, P., Tremoli, E., Poli, A., Oreste, P., & Paoletti, R. (1986) · Circulation · doi:10.1161/01.cir.74.6.1399 · Cited by 2,404 · cited 1×
“Carotid intimal media thickness (CIMT) measurements are an alternative method of evaluating arterial stiffness (22).”
MethodThe Reference Values for Arterial Stiffness' Collaboration (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq165 · Cited by 2,087
ApoE-deficient mice develop lesions of all phases of atherosclerosis throughout the arterial tree.
Nakashima, Y., Plump, A. S., Raines, E. W., Breslow, J. L., & Ross, R. (1994) · Arteriosclerosis and Thrombosis: A Journal of Vascular Biology · doi:10.1161/01.atv.14.1.133 · Cited by 1,693 · cited 1×
“Furthermore, atherosclerosis tends to develop at branching points (55), which is problematic for imaging along a straight line, especially in the thoracic aorta.”
BackgroundStrong, J. P. (1999) · JAMA · doi:10.1001/jama.281.8.727 · Cited by 1,001 · cited 1×
“Studies have demonstrated that all individuals between the ages of 15 and 34 years have some degree of aortic fatty streaks (1), which are early forms of atherosclerotic plaques.”
BackgroundNoninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events
Oliver, J. J., & Webb, D. J. (2003) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000060460.52916.d6 · Cited by 823 · cited 2×
“Oliver JJ, Webb DJ. Noninvasive assessment of arterial stiffness and risk of atherosclerotic events.”
MethodDen Ruijter, H. M., Peters, S. A. E., Anderson, T. J., Britton, A. R., Dekker, J. M., Eijkemans, M. J., Engström, G., Evans, G. W., de Graaf, J., Grobbee, D. E., et al. (2012) · JAMA · doi:10.1001/jama.2012.9630 · Cited by 760 · cited 3×
“In comparison, one initial study has demonstrated that PWV measurements do indeed improve the predictive accuracy of the FRS (25).”
MethodClinical applications of arterial stiffness, Task Force III: recommendations for user procedures
Van Bortel, L. M., Duprez, D., Starmans-Kool, M. J., Safar, M. E., Giannattasio, C., Cockcroft, J., Kaiser, D. R., & Thuillez, C. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02326-3 · Cited by 630 · cited 1×
“Also, obesity is a cause of operator bias in PWV measurements with applanation tonometry (18-20).”
BackgroundRedheuil, A., Yu, W.-C., Wu, C. O., Mousseaux, E., de Cesare, A., Yan, R., Kachenoura, N., Bluemke, D., & Lima, J. A. C. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141275 · Cited by 386 · cited 1×
“Another method that uses information in the upstroke fits a sigmoid to the upstroke and searches for the temporal shift in the maximum curvature between two flow waveforms (30,31).”
MethodRajzer, M. W., Wojciechowska, W., Klocek, M., Palka, I., Brzozowska-Kiszka, M., & Kawecka-Jaszcz, K. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e32830a4a25 · Cited by 308 · cited 1×
“However, the distance measurement used in applanation tonometry and Doppler ultrasound can cause errors of up to 30% for the measurement of PWV (2,11,12).”
MethodMohiaddin, R. H., Underwood, S. R., Bogren, H. G., Firmin, D. N., Klipstein, R. H., Rees, R. S., & Longmore, D. B. (1989) · Heart · doi:10.1136/hrt.62.2.90 · Cited by 279 · cited 1×
“It is prudent to briefly discuss the analysis of vessel cross-sectional area as a marker for vascular stiffness (26,57).”
BackgroundNelson, M. R., Stepanek, J., Cevette, M., Covalciuc, M., Hurst, R. T., & Tajik, A. J. (2010) · Mayo Clinic Proceedings · doi:10.4065/mcp.2009.0336 · Cited by 264 · cited 1×
“PWV is measured clinically with applanation tonometry (8,9) and Doppler ultrasound (9,10).”
MethodAge-associated changes in regional aortic pulse wave velocity
Rogers, W. J., Hu, Y.-L., Coast, D., Vido, D. A., Kramer, C. M., Pyeritz, R. E., & Reichek, N. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01504-2 · Cited by 219 · cited 1×
“evaluated multi-slice 2D PC MR-based PWV measurements and compared them to applanation tonometry as a reference standard (65,66).”
MethodValidation and reproducibility of aortic pulse wave velocity as assessed with velocity‐encoded MRI
Grotenhuis, H. B., Westenberg, J. J. M., Steendijk, P., van der Geest, R. J., Ottenkamp, J., Bax, J. J., Jukema, J. W., & de Roos, A. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21886 · Cited by 204 · cited 1×
“Multi-slice 2D PC MR-based PWV measurements were also validated against intravascular pressure measurements in 18 patients (67); good agreement was found between methods, with Pearson correlation coefficients ranging from 0.”
MethodVoges, I., Jerosch-Herold, M., Hedderich, J., Pardun, E., Hart, C., Gabbert, D. D., Hansen, J. H., Petko, C., Kramer, H.-H., & Rickers, C. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-77 · Cited by 187
Mohiaddin, R. H., Firmin, D. N., & Longmore, D. B. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.1.492 · Cited by 184 · cited 2×
“It is prudent to briefly discuss the analysis of vessel cross-sectional area as a marker for vascular stiffness (26,57).”
BackgroundMethodPulse wave imaging of the human carotid artery: an in vivo feasibility study
Luo, J., Li, R. X., & Konofagou, E. E. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2170 · Cited by 165 · cited 1×
“org While applanation tonometry and Doppler ultrasound provide a global measurement of PWV, it should be noted that a recent ultrasound study was able to evaluate PWV regionally within the carotid artery (21).”
BackgroundComparative study of methodologies for pulse wave velocity estimation
Salvi, P., Magnani, E., Valbusa, F., Agnoletti, D., Alecu, C., Joly, L., & Benetos, A. (2008) · Journal of Human Hypertension · doi:10.1038/jhh.2008.42 · Cited by 160 · cited 1×
“However, the distance measurement used in applanation tonometry and Doppler ultrasound can cause errors of up to 30% for the measurement of PWV (2,11,12).”
MethodHuybrechts, S. A. M., Devos, D. G. H., Vermeersch, S. J., Mahieu, D., Achten, E., Backer, T. L. M. D., Segers, P., & Bortel, L. M. V. (2011) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283487841 · Cited by 155 · cited 1×
“Equations to correct for inaccuracies in these distance measurements have been reported (13,14).”
BackgroundEstimation of local aortic elastic properties with MRI
Vulliémoz, S., Stergiopulos, N., & Meuli, R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10100 · Cited by 152 · cited 1×
“Compliance also can be used to derive PWV such that PWV=∆Q/∆A; this is termed the QA method (59-61).”
MethodEstimation of global aortic pulse wave velocity by flow‐sensitive 4D MRI
Markl, M., Wallis, W., Brendecke, S. M., Simon, J., Frydrychowicz, A. P., & Harloff, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22353 · Cited by 144 · cited 1×
“However, the achievable tempora l reso lut ion i s compromised and ranges from 32-50 ms with a scan time of 10-20 minutes (43-45).”
BackgroundIbrahim, E. H., Johnson, K. R., Miller, A. B., Shaffer, J. M., & White, R. D. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-26 · Cited by 110 · cited 2×
“found the TTF method to be more reliable than the XCorr method (33).”
MethodJoly, L., Perret‐Guillaume, C., Kearney‐Schwartz, A., Salvi, P., Mandry, D., Marie, P., Karcher, G., Rossignol, P., Zannad, F. M., & Bénétos, A. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.133645 · Cited by 109 · cited 1×
“Also, obesity is a cause of operator bias in PWV measurements with applanation tonometry (18-20).”
BackgroundJiang, B., Liu, B., McNeill, K. L., & Chowienczyk, P. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.09.008 · Cited by 105 · cited 1×
“PWV is measured clinically with applanation tonometry (8,9) and Doppler ultrasound (9,10).”
MethodFielden, S. W., Fornwalt, B. K., Jerosch‐Herold, M., Eisner, R. L., Stillman, A. E., & Oshinski, J. N. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21387 · Cited by 103 · cited 2×
“Cross-correlation (XCorr) is a method of computing PWV that uses the entire flow waveform (32).”
MethodDistal Shift of Arterial Pressure Wave Reflection Sites With Aging
Sugawara, J., Hayashi, K., & Tanaka, H. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.160549 · Cited by 99 · cited 1×
“The site of pulse wave reflection varies with age (40), so it cannot be accurately predicted in which slices reflected waves will affect relevant regions of flow waveforms (such as the foot of the waveforms).”
BackgroundWestenberg, J. J. M., van Poelgeest, E. P., Paul Steendijk, A., Grotenhuis, H. B., Jukema, J. W., & Roos, A. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-2 · Cited by 90 · cited 1×
“(56,69) compared both multi-slice one-directional through-plane and in-plane two-directional 2D PC PWV measurements to gold standard intravascular pressure probe PWV measurements in 14-17 patients.”
Backgroundvan der Meer, R. W., Diamant, M., Westenberg, J. J. M., Doornbos, J., Bax, J. J., Roos, A., & Lamb, H. J. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640601093703 · Cited by 89 · cited 2×
“As described in the section above, the simplest method to derive PWV from MR data is to determine the temporal shift between the two flow waveforms (28,29,34).”
MethodLehmann, E. D., Parker, J. R., Hopkins, K. D., Taylor, M. G., & Gosling, R. G. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90118-i · Cited by 85 · cited 1×
“PWV is measured clinically with applanation tonometry (8,9) and Doppler ultrasound (9,10).”
MethodDogui, A., Redheuil, A. B., Lefort, M., Cesare, A. D., Kachenoura, N., Herment, A., & Mousseaux, É. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22570 · Cited by 84 · cited 1×
“Another method that uses information in the upstroke fits a sigmoid to the upstroke and searches for the temporal shift in the maximum curvature between two flow waveforms (30,31).”
MethodDistance measurements for the assessment of carotid to femoral pulse wave velocity
Vermeersch, S. J., Rietzschel, E. R., Buyzere, M. D., Bortel, L. M. V., Gillebert, T. C., Verdonck, P., Laurent, S., Segers, P., & Boutouyrie, P. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283313a8a · Cited by 84 · cited 1×
“Equations to correct for inaccuracies in these distance measurements have been reported (13,14).”
BackgroundMarkl, M., Wallis, W., Strecker, C., Gladstone, B. P., Vach, W., & Harloff, A. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22856 · Cited by 84 · cited 1×
“However, the achievable tempora l reso lut ion i s compromised and ranges from 32-50 ms with a scan time of 10-20 minutes (43-45).”
BackgroundEstimation of aortic compliance using magnetic resonance pulse wave velocity measurement
Boese, J. M., Bock, M., Schoenberg, S. O., & Schad, L. R. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/320 · Cited by 77 · cited 2×
“As described in the section above, the simplest method to derive PWV from MR data is to determine the temporal shift between the two flow waveforms (28,29,34).”
MethodWentland, A. L., Wieben, O. E., François, C. J., Boncyk, C. S., del Río, A. M., Johnson, K. M., Grist, T. M., & Frydrychowicz, A. P. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23877 · Cited by 72 · cited 2×
“Time-resolved 3-dimensional 4D PC MRI with volumetric coverage and velocity sensitivity in all three spatial directions has also been used to compute PWV (Figure 6) (41-43).”
BackgroundMethodSelf-citationMethods of blood flow measurement in the arterial circulatory system
Tabrizchi, R., & Pugsley, M. K. (2000) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(00)00123-4 · Cited by 68 · cited 1×
“PWV a l so can be measured wi th t rans i t - t ime ultrasound flow meters (7).”
BackgroundCardiothoracic Magnetic Resonance Flow Imaging
Hope, M. D., Sedlic, T., & Dyverfeldt, P. (2013) · Journal of Thoracic Imaging · doi:10.1097/rti.0b013e31829192a1 · Cited by 61 · cited 1×
“Furthermore, a 4D PC MRI approach provides the opportunity to derive other hemodynamic parameters of interest from the same scan, including wall shear stress, pressure gradients across stenoses, and other parameters (46).”
BackgroundYu, H., Peng, H., Wang, J., Wen, C., & Tseng, W. I. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21034 · Cited by 60 · cited 1×
“The time-to-foot (TTF) method is one such method that uses several time points (Figure 4) (26-29).”
MethodWestenberg, J. J. M., Roos, A., Grotenhuis, H. B., Paul Steendijk, A., Hendriksen, D., van den Boogaard, P. J., van der Geest, R. J., Bax, J. J., Jukema, J. W., & Reiber, J. H. C. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22359 · Cited by 56
Feasibility of aortic pulse pressure and pressure wave velocity MRI measurement in young adults
Laffon, É., Marthan, R., Montaudon, M., Latrabe, V., Laurent, F., & Ducassou, D. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20227 · Cited by 54 · cited 1×
“The calculation can be performed by acquiring two 2D PC slices and extracting the flow waveforms from each slice (34-36) or more simply by acquiring a single 2D PC slice in the thoracic aorta that transects both the ascending and descending portions of the aorta—thus providing two flow waveforms (37).”
MethodIn vivo measurement of local aortic pulse‐wave velocity in mice with MR microscopy at 17.6 tesla
Herold, V., Parczyk, M., Mörchel, P., Ziener, C. H., Klug, G., Bauer, W. R., Rommel, E., & Jakob, P. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21957 · Cited by 53 · cited 1×
“Compliance also can be used to derive PWV such that PWV=∆Q/∆A; this is termed the QA method (59-61).”
MethodLeeson, C. P. M., Robinson, M., Francis, J. M., Robson, M. D., Channon, K. M., Neubauer, S., & Wiesmann, F. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640500526993 · Cited by 51 · cited 1×
“The calculation can be performed by acquiring two 2D PC slices and extracting the flow waveforms from each slice (34-36) or more simply by acquiring a single 2D PC slice in the thoracic aorta that transects both the ascending and descending portions of the aorta—thus providing two flow waveforms (37).”
MethodPeng, H., Chung, H., Yu, H., & Tseng, W. I. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20782 · Cited by 46 · cited 1×
“Compliance also can be used to derive PWV such that PWV=∆Q/∆A; this is termed the QA method (59-61).”
MethodBérard, E., Bongard, V., Ruidavets, J., Amar, J., & Ferrières, J. (2013) · Journal of Human Hypertension · doi:10.1038/jhh.2013.8 · Cited by 40 · cited 2×
“In comparison, one initial study has demonstrated that PWV measurements do indeed improve the predictive accuracy of the FRS (25).”
Taviani, V., Hickson, S. S., Hardy, C. J., McEniery, C. M., Patterson, A. J., Gillard, J. H., Wilkinson, I. B., & Graves, M. J. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22590 · Cited by 35 · cited 2×
“The FVE M-mode method of computing PWV was briefly validated in four human subjects with intravascular pressure probes (50).”
BackgroundMethodPulse‐wave velocity measured in one heartbeat using MR tagging
Macgowan, C. K., Henkelman, R. M., & Wood, M. L. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10177 · Cited by 33 · cited 1×
“Simpler 1D projection velocity methods have been proposed that provide a temporal resolution of ~2 ms (51-53).”
MethodIbrahim, E. H., Shaffer, J. M., & White, R. D. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.04.012 · Cited by 33 · cited 1×
“org slice 2D PC MRI-based PWV measurements and this QA method in the pulmonary arteries (62).”
MethodNoninvasive assessment of carotid-femoral pulse wave velocity
Bossuyt, J., de Velde, S. V., Azermai, M., Vermeersch, S. J., Backer, T. L. M. D., Devos, D., Heyse, C., Filipovský, J., Segers, P., & Bortel, L. M. V. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328360275d · Cited by 28 · cited 1×
“Another problem with these techniques is that the method for measuring distance between the carotid and femoral arteries is not standardized and can lead to variations in the path-length used for PWV measurements (15-17).”
MethodTaviani, V., Patterson, A. J., Graves, M. J., Hardy, C. J., Worters, P. W., Sutcliffe, M. P. F., & Gillard, J. H. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22143 · Cited by 27 · cited 1×
“5 ms (49,50), which is much better than the temporal resolution obtained with traditional imaging.”
BackgroundMochida, M., Sakamoto, H., Sawada, Y., Yokoyama, H., Sato, M., Sato, H., Oyama, Y., Kurabayashi, M., Tamura, J., & Sakamaki, T. (2006) · Angiology · doi:10.1177/000331970605700112 · Cited by 26 · cited 1×
“While FVE M-mode imaging provides superior temporal resolution compared to other MR-based methods, the need to image along a straight vessel segment is a limitation, especially because vessels burdened with atherosclerotic disease tend to become tortuous over time (54).”
MethodSuever, J. D., Oshinski, J. N., Campos, E. R., Huneycutt, D., Cardarelli, F., Stillman, A. E., & Raggi, P. (2011) · International journal of cardiac imaging · doi:10.1007/s10554-011-9929-8 · Cited by 26 · cited 1×
“evaluated multi-slice 2D PC MR-based PWV measurements and compared them to applanation tonometry as a reference standard (65,66).”
MethodShan, Y., Lin, J., Xu, P., Zhou, J., & Zeng, M.-S. (2012) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e31825b823e · Cited by 10 · cited 1×
“The calculation can be performed by acquiring two 2D PC slices and extracting the flow waveforms from each slice (34-36) or more simply by acquiring a single 2D PC slice in the thoracic aorta that transects both the ascending and descending portions of the aorta—thus providing two flow waveforms (37).”
MethodWentland, A. L., Korosec, F. R., Vigen, K. K., Wieben, O. E., Fine, J. P., & Grist, T. M. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20715 · Cited by 10 · cited 1×
“It has also been shown that retrospective gating with radial PC acquisitions can be used, as this sampling scheme allows for undersampling and the ability to image within the time of a breath hold as well as for flexible retrospective gating since the center of k-space is acquired in every readout (64).”
BackgroundSelf-citation
Cited by
Targeting vascular (endothelial) dysfunction
Daiber, A., Steven, S., Weber, A., Shuvaev, V. V., Muzykantov, V. R., Laher, I., Li, H., Lamas, S., & Münzel, T. (2017) · British Journal of Pharmacology · doi:10.1111/bph.13517 · Cited by 501
“Nevertheless, their invasiveness limits their use in clinical studies (Wentland et al., 2014).”
BackgroundSCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance
Leiner, T., Bogaert, J., Friedrich, M. G., Mohiaddin, R., Muthurangu, V., Myerson, S., Powell, A. J., Raman, S. V., & Pennell, D. J. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00682-4 · Cited by 328
Mechanistic Insights of Empagliflozin in Nondiabetic Patients With HFrEF
Requena-Ibáñez, J. A., Santos-Gallego, C. G., Rodriguez-Cordero, A., Vargas-Delgado, A. P., Mancini, D., Sartori, S., Atallah-Lajam, F., Giannarelli, C., Macaluso, F., Lala, A., et al. (2021) · JACC: Heart Failure · doi:10.1016/j.jchf.2021.04.014 · Cited by 264
Experimental validation of dual PPG local pulse wave velocity probe
Nabeel, P. M., Karthik, S., Joseph, J., & Sivaprakasam, M. (2017) · 2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2017.7985911 · Cited by 20
“Non-invasive local PWV techniques such as magnetic resonance imaging [6], [9], [10], ultrasound method with higher frame-rate [11], Doppler velocity in combination with arterial pressure [12], pulse wave Research supported by Science and Engineering Research Board (SERB), Dept.”
Method
Metadata
- Authors
- Wentland, A. L., Grist, T. M., & Wieben, O. E.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 2014-04-01
- Volume
- 4
- Issue
- 2
- Pages
- 193-206
- OpenAlex
- W1912189336
- Cited by
- 166
- References
- 54
- FWCI
- 11.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.