CoChat

A Chromosome 4q25 Variant is Associated with Atrial Fibrillation Recurrence After Catheter Ablation: A Systematic Review and Meta-Analysis

Open access
Rattanawong, Pattara · 2018 · Journal of Atrial Fibrillation
Cited by 22

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Recent studies suggested that variants on chromosome loci 4q25, 1q21, and 16q22 were associated with atrial fibrillation recurrence after catheter ablation. In this study, we performed a systematic review and meta-analysis to explore the association between variants on chromosome loci 4q25, 1q21, and 16q22 and atrial fibrillation recurrence after catheter ablation. METHODS: We comprehensively searched the databases of MEDLINE and EMBASE from inception to January 2017. Included studies were published prospective or retrospective cohort and case control studies that compared the risk of atrial fibrillation recurrence after catheter ablation in AF patients with chromosome 4q25, 1q21, and 16q22 variants versus no variants. Single-nucleotide polymorphism rs1906617, rs2106261, rs7193343, rs2200733, rs10033464, rs13376333, and rs6843082 were included in this analysis. Data from each study were combined using the random-effects, generic inverse variance method of DerSimonian and Laird to calculate the risk ratios and 95% confidence intervals. RESULTS: Seven studies from January 2010 to June 2017 involving 3,322 atrial fibrillation patients were included in this meta-analysis. According to the pooled analysis, there was a strong independent association between chromosome 4q25 variant (rs2200733) and the risk of atrial fibrillation recurrence after catheter ablation (risk ratio 1.45 [95% confidence interval 1.15-1.83], P = 0.002). No association was found in other variants. CONCLUSION: Our meta-analysis demonstrates a statistically significant increased risk of atrial fibrillation recurrence after catheter ablation in 4q25 variant (only in rs2200733) but not in 1q21 or 16q22 variants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4022/jafib.1666

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 22

Metadata

Authors
Rattanawong, P.
Venue
Journal of Atrial Fibrillation
Published
2018-04
Volume
10
Issue
6
Pages
1666-1666
ISSN
1941-6911 (ISSN-L)
OpenAlex
W2805239952
Cited by
22
References
4
FWCI
0.71
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Chromosome 4q25 Variant is Associated with Atrial Fibrillation Recurrence After Catheter Ablation: A Systematic Review and Meta-Analysis. https://app.cochat.ai/papers/10.4022/jafib.1666
The paper
Rattanawong, P. (2018). A Chromosome 4q25 Variant is Associated with Atrial Fibrillation Recurrence After Catheter Ablation: A Systematic Review and Meta-Analysis. Journal of Atrial Fibrillation. https://doi.org/10.4022/jafib.1666

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.