The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Evaluation of Nursing Work Effort and Perceptions About Blood Glucose Testing in Tight Glycemic Control
Open accessAbstract
• Background Tight glycemic control is important in critically ill patients and involves insulin infusions and monitoring of blood glucose levels. Hourly measurements of blood glucose levels and adjustments of intravenous insulin doses require additional work by nurses. • Objectives To evaluate the nursing work incurred with and nursing perceptions about tight glycemic control and blood glucose monitoring. • Methods A variety of intensive care units were studied. Surveys were used to gain information about nurses’ perceptions. Time-in-motion observations were used to determine the time taken to measure blood glucose levels and adjust insulin doses. • Results Nurses thought that tight glycemic control was important and that the work associated with it was substantial. Nurses thought that easier and automated forms of blood glucose monitoring are needed. They preferred using an arterial catheter to obtain blood samples to avoid excessive finger sticks. The total number of blood glucose measurements was 77 954. The mean time taken for hourly blood glucose monitoring and adjustment of insulin doses was 4.72 minutes. The estimated costs of time spent on glycemic control during a 1-year period were $182 488 for nurses’ salaries and $58 500 for supplies. • Conclusions Although most nurses endorse tight glycemic control, the work associated with it is burdensome and costly. Because up to 2 hours might be required for tight glycemic control for a single patient in a 24-hour period, the costs in time and money are high. Easier clinical methods for monitoring blood glucose levels are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Capes, S. E., Hunt, D., Malmberg, K., & Gerstein, H. C. (2000) · The Lancet · doi:10.1016/s0140-6736(99)08415-9 · Cited by 2,187
Furnary, A. P., Zerr, K. J., Grunkemeier, G. L., & Starr, A. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(99)00014-4 · Cited by 1,230
Effect of an Intensive Glucose Management Protocol on the Mortality of Critically Ill Adult Patients
Krinsley, J. S. (2004) · Mayo Clinic Proceedings · doi:10.4065/79.8.992 · Cited by 1,223
Krinsley, J. S. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.12.1471 · Cited by 1,165
Furnary, A. P., Gao, G., Grunkemeier, G. L., Wu, Y., Zerr, K. J., Bookin, S. O., Floten, H. S., & Starr, A. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.181 · Cited by 1,130
Implementation of a Safe and Effective Insulin Infusion Protocol in a Medical Intensive Care Unit
Goldberg, P. A., Siegel, M. D., Sherwin, R. S., Halickman, J. I., Lee, M., Bailey, V. A., Lee, S. L., Dziura, J. D., & Inzucchi, S. E. (2004) · Diabetes Care · doi:10.2337/diacare.27.2.461 · Cited by 483
Pittas, A. G., Siegel, R. D., & Lau, J. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.18.2005 · Cited by 306
Reduction of Nosocomial Infections in the Surgical Intensive-Care Unit by Strict Glycemic Control
Grey, N. J., & Perdrizet, G. A. (2004) · Endocrine Practice · doi:10.4158/ep.10.s2.46 · Cited by 258
Experience with the Continuous Glucose Monitoring System® in a Medical Intensive Care Unit
Goldberg, P. A., Siegel, M. D., Russell, R. R., Sherwin, R. S., Halickman, J. I., Cooper, D. A., Dziura, J. D., & Inzucchi, S. E. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198034 · Cited by 158
Cited by
Intensive versus Conventional Glucose Control in Critically Ill Patients
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810625 · Cited by 5,119
Benefits and Risks of Tight Glucose Control in Critically Ill Adults: A Meta-analysis
Wiener, R. S., Wiener, D. C., & Larson, R. J. (2008) · JAMA · doi:10.1001/jama.300.8.933 · Cited by 200
Preiser, J.-C., Devos, P., Ruiz-Santana, S., Mélot, C., Annane, D., Groeneveld, J., Iapichino, G., Leverve, X., Nitenberg, G., Singer, P., et al. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1585-2 · Cited by 911
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Intensive Insulin Therapy in Hospitalized Patients: A Systematic Review
Kansagara, D., Fu, R., Freeman, M., Wolf, F., & Helfand, M. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-4-201102150-00008 · Cited by 255
Metadata
- Authors
- Aragon, D.
- Venue
- American Journal of Critical Care
- Publisher
- AACN Publishing
- Published
- 2006-07-01
- Volume
- 15
- Issue
- 4
- Pages
- 370-377
- ISSN
- 1062-3264 (ISSN-L)
- 1937-710X
- OpenAlex
- W2140259139
- Cited by
- 370
- References
- 16
- FWCI
- 39.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Nursing Work Effort and Perceptions About Blood Glucose Testing in Tight Glycemic Control. https://app.cochat.ai/papers/10.4037/ajcc2006.15.4.370
- The paper
- Aragon, D. (2006). Evaluation of Nursing Work Effort and Perceptions About Blood Glucose Testing in Tight Glycemic Control. American Journal of Critical Care. https://doi.org/10.4037/ajcc2006.15.4.370
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.