Arm Circumference, Shape, and Length: How Interplaying Variables Affect Blood Pressure Measurement in Obese Persons
Abstract
Obesity has reached epidemic proportions worldwide.1 The World Health Organization projects that by 2015 2.3 billion persons will be overweight (body mass index [BMI, calculated as weight in kilograms divided by height in meters squared], 25–29), and another 700 million will be obese (with BMI ≥ 30).2 In the United States alone, more than 78 million adults (35.7%) and 12.5 million children and adolescents (16.9%) are obese.3 As obesity has increased, so has arm circumference, especially to greater than 33 cm. This increasing prevalence creates unique demands for clinicians caring for obese persons across the lifespan in all practice settings. Even basic assessment techniques such as measurement of blood pressure are challenging.4–6Accuracy of blood pressure measurement is contingent on many factors, including correct cuff size and location of measurement.7 According to the American Heart Association (AHA8; Table 1), ideal cuffs have bladder widths at least 40% and lengths 80% of midarm circumference (length to width ratio of 2:1). Therefore, cuff bladders must get longer and wider as arm circumference increases; otherwise mismatching may occur. The most common mismatch is using small or short cuffs (bladder too small).9 Such “undercuffing” leads to overestimates of systolic blood pressure (SBP) and diastolic blood pressure (DBP; range of error, 2.4–30 mm Hg), resulting in erroneous classification of patients as hypertensive, leading to unnecessary therapy.8–10In addition to arm circumference, researchers in a recent study determined that upper arms are troncoconical in shape (obese or not).11 Differences between proximal and distal upper arm circumference ranged from 1 to 20 cm, with a mean of 8.7 cm. Although sex and degree of obesity influenced shape, arm circumference was the factor that most significantly influenced conicity index. Increased conicity associated with obesity (or muscularity) can result in poor cuff fit.12 To complicate matters more, obese patients of small stature may have short upper arms.10 Thus, if cuffs that are too wide are used (bladders too large), arm length poses a problem. Although thigh cuffs may be the best fit for the arm circumference, the distal cuff end will be too long, extending past the elbow/antecubital fossa. This situation results in “overcuffing,” which yields a false underestimate of blood pressure (range of error, 10–30 mm Hg).9,10 These anatomic challenges and the many cuff choices are compounded by the potential lack of consistent use of a particular cuff size between clinicians, further reducing the reliability of blood pressure values that guide critical treatment decisions. As a result, the following PICO (population, intervention, control, and outcomes) question was chosen for this clinical review: What is the most accurate method of assessing blood pressure in obese persons?A search of the MEDLINE and CINAHL databases, limited to the past 10 years, was conducted with the following search terms: obese, overweight, blood pressure monitoring, cuff size, and conical shaped.Eleven observational studies were retrieved (Table 2). In 2 studies,11,13 cuff types were compared (standard vs large, rigid cylindrical vs conical); in 3 studies,4,17,21 blood pressure measurements obtained via direct intra-arterial vs ausculatory/oscillometric techniques were compared; and in 6 studies,14–16,18–20 blood pressure measurements obtained from the upper arm versus the forearm were compared.Existing evidence on blood pressure assessment in obese persons is at level C (Table 3). Not surprisingly, current evidence suggests that when vital decisions are required in the treatment of critically ill obese patients, direct intra-arterial measurement of blood pressure should be used instead of ausculatory/oscillometric techniques, which are associated with significant error.4,17A second recommendation relates to matching cuffs with the size and shape of the upper arm. Preferably on admission, clinicians should measure the arm circumference midway between the shoulder and elbow and evaluate the shape of the upper arm. Based on size and shape dimensions, an appropriately sized cuff as closely aligned to the AHA’s guidelines as possible should be selected. This assessment is essential as evidence shows that standard cuffs yield overestimates of blood pressure in obese persons13 compared with larger appropriately sized cuffs.Although the AHA recommends long cuffs with large arm circumferences and short upper arms,8 McFarlane10 points out that these cuffs do not meet the bladder size standard because only the outside cuff material is extra long. Indeed, Watson et al20 reported that extra-long cuffs used on the upper arm in patients with large arm circumferences were associated with significantly higher SBP (compared with standard cuffs). In an unpublished study, McFarlane compared blood pressure measurements obtained in the forearm and upper arm using extra-long versus appropriately-sized cu
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
An automated oscillometric device successfully validated in adults may not be accurate in pregnancy or preeclampsia.
“An automated oscillometric device, which has been successfully validated in adults may not be accurate in pregnancy or preeclampsia [90,191]”
Using a standard size cuff on large arms can overestimate BP.
“One of the main issues in the management of patients with large arm circumference is the limited availability of properly sized cuffs, which can end up in an overestimation of BP whilst using a standard size cuff [194,195].”
Limited availability of properly sized cuffs is a main issue in managing patients with large arm circumference.
“One of the main issues in the management of patients with large arm circumference is the limited availability of properly sized cuffs, which can end up in an overestimation of BP whilst using a standard size cuff [194,195].”
Cites
Haslam, D. W., & James, W. P. T. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67483-1 · Cited by 3,757 · see citing works
Prevalence of obesity in the United States, 2009-2010.
Ogden, C. L., Carroll, M. D., Kit, B. K., & Flegal, K. M. (2012) · PubMed · Cited by 2,070 · see citing works
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051 · see citing works
American Association of Critical-Care Nurses
Notes, L. S. (1990) · Critical Care Nursing Quarterly · doi:10.1097/00002727-199009000-00013 · Cited by 681 · see citing works
Principles and techniques of blood pressure measurement.
Pickering, T. (2002) · Cardiology Clinics · doi:10.1016/s0733-8651(01)00009-1 · Cited by 299 · see citing works
Principles and techniques of blood pressure measurement
Ogedegbe, G., & Pickering, T. (2002) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 290 · see citing works
Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
Araghi, A., Bander, J. J., & Guzman, J. A. (2006) · Critical Care · doi:10.1186/cc4896 · Cited by 115 · see citing works
Blood pressure measurement in very obese patients: a challenging problem
Palatini, P., & Parati, G. (2011) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283435b65 · Cited by 72 · see citing works
Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements
Pierin, Â. M. G., Alavarce, D. C., de Gusmão, J. L., Halpern, A., & Mion, D. (2004) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000132425.25263.ac · Cited by 70 · see citing works
Fonseca‐Reyes, S., de Alba-García, J. G., Parra-Carrillo, J. Z., & Paczka-Zapata, J. A. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200306000-00002 · Cited by 69 · see citing works
Bonso, E., Saladini, F., Zanier, A., Benetti, E., Dorigatti, F., & Palatini, P. (2010) · Hypertension Research · doi:10.1038/hr.2010.146 · Cited by 63 · see citing works
Umaña, E., Ahmed, W., Fraley, M. A., & Alpert, M. (2006) · Angiology · doi:10.1177/000331970605700106 · Cited by 56 · see citing works
Upgrading the American Association of Critical-Care Nurses' Evidence-Leveling Hierarchy
Armola, R. R., Bourgault, A. M., Halm, M. A., R. M. Board, Bucher, L., Harrington, L., Heafey, C. A., Lee, R. K., Shellner, P., & Medina, J. (2009) · American Journal of Critical Care · doi:10.4037/ajcc2009170 · Cited by 52 · see citing works
Self-citationSchell, K. A., Bradley, E., Bucher, L., Seckel, M. A., Lyons, D. L., Wakai, S., Bartell, D., Carson, E. A., Chichester, M., Foraker, T., et al. (2005) · American Journal of Critical Care · doi:10.4037/ajcc2005.14.3.232 · Cited by 42 · see citing works
Emerick, D. B. (2002) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0203000108 · Cited by 33 · see citing works
Clinical and critical care concerns in severely ill obese patient
Bajwa, S. J., Sehgal, V., & Bajwa, S. (2012) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/2230-8210.100667 · Cited by 30 · see citing works
Blood pressure assessment in severe obesity: Validation of a forearm approach
Leblanc, M., Croteau, S., Ferland, A., Bussières, J. S., Cloutier, L., Hould, F., Biertho, L. D., Moustarah, F., Marceau, S., & Poirier, P. (2013) · Obesity · doi:10.1002/oby.20458 · Cited by 29 · see citing works
Obesity: An Emerging Concern for Patients and Nurses
Camden, S. G. (2009) · OJIN The Online Journal of Issues in Nursing · doi:10.3912/ojin.vol14no1man01 · Cited by 25 · see citing works
Comparison of Upper Arm and Forearm Blood Pressure
Domiano, K. L., Hinck, S. M., Savinske, D. L., & Hope, K. L. (2008) · Clinical Nursing Research · doi:10.1177/1054773808324651 · Cited by 20 · see citing works
Schell, K., Lyons, D. L., Bradley, E., Bucher, L., Seckel, M. A., Wakai, S., Carson, E. A., Waterhouse, J. K., Chichester, M., Bartell, D., et al. (2006) · American Journal of Critical Care · doi:10.4037/ajcc2006.15.2.196 · Cited by 17 · see citing works
Brachial or wrist blood pressure in obese patients: which is the best?
Senarclens, O. D., Feihl, F., Giusti, V., Engelberger, R. P., Rodieux, F., Gomez, P., Liaudet, L., & Waeber, B. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3282fd16e3 · Cited by 15 · see citing works
Watson, S., Aguas, M., Bienapfl, T., Colegrove, P., Foisy, N., Jondahl, B., Yosses, M. B., Yu, L., & Anastas, Z. (2011) · Journal of PeriAnesthesia Nursing · doi:10.1016/j.jopan.2011.02.001 · Cited by 11 · see citing works
Blood Pressure Measurement in Obese Patients
McFarlane, J. (2012) · Critical Care Nurse · doi:10.4037/ccn2012489 · Cited by 9 · see citing works
Fecal peritonitis in pigs as a model of extrapulmonary ALI/ARDS
Calzia, E., Bassi, G., Nguyen, C., Radermacher, P., Hauser, B., Asfar, P., Ploner, F., Barth, E., & Matějovič, M. (2006) · Critical Care · doi:10.1186/cc4349 · Cited by 9 · see citing works
Of Funnel Arms, Popeye, and Other‐Sized Challenges
Townsend, R. R. (2005) · Journal of Clinical Hypertension · doi:10.1111/j.1524-6175.2005.04146.x · Cited by 8 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Flynn, J. T., Kaelber, D. C., Baker-Smith, C. M., Blowey, D., Carroll, A. E., Daniels, S. R., de Ferranti, S. D., Dionne, J. M., Falkner, B., Flinn, S. K., et al. (2017) · Pediatrics · doi:10.1542/peds.2017-1904 · Cited by 3,651 · see citing works
Parati, G., Stergiou, G. S., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Agarwal, R., Asayama, K., Asmar, R., Burnier, M., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002922 · Cited by 178 · see citing works
“One of the main issues in the management of patients with large arm circumference is the limited availability of properly sized cuffs, which can end up in an overestimation of BP whilst using a standard size cuff [194,195].”
Brazilian Guidelines for In-office and Out-of-office Blood Pressure Measurement – 2023
Feitosa, A. D. D. M., Barroso, W., Mion, D., Nobre, F., Mota-Gomes, M., Jardim, P. C. V., Amodeo, C., Oliveira, A. C., Alessi, A., Sousa, A. L. L., et al. (2024) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240113i · Cited by 55 · see citing works
“In this setting, the use of inadequate cuffs may lead to overestimation of BP. 172 In the absence of appropriately sized or shaped cuffs, validated and calibrated wrist devices may serve as an alternative for HBPM in patients with obesity.”
BackgroundInfluentialDiretrizes Brasileiras de Medidas da Pressão Arterial Dentro e Fora do Consultório – 2023
Feitosa, A. D. D. M., Barroso, W., Mion, D., Nobre, F., Mota-Gomes, M., Jardim, P. C. V., Amodeo, C., Oliveira, A. C., Alessi, A., Sousa, A. L. L., et al. (2024) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240113 · Cited by 38 · see citing works
Perioperative Blood Pressure Monitoring in Patients With Obesity
Eley, V. A., Christensen, R., Guy, L., & Dodd, B. R. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003647 · Cited by 24 · see citing works
Deng, Z., & Liang, F. (2016) · Acta Mechanica Sinica · doi:10.1007/s10409-016-0587-x · Cited by 19 · see citing works
“, width and length of cuff) [10], biomechanical properties (e.”
BackgroundA review of blood pressure measurement in obese pregnant women
Eley, V. A., Christensen, R., Kumar, S., & Callaway, L. K. (2018) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2018.04.004 · Cited by 12 · see citing works
On Low-Value Nursing Care: Part 1, Why De-implementation Matters for Quality Care
Halm, M. A. (2022) · American Journal of Critical Care · doi:10.4037/ajcc2022857 · Cited by 8 · see citing works
Self-citationArm and finger measurements in the third trimester: Implications for blood pressure measurement
Eley, V. A., Roberts, L., Rickards, L., Pelecanos, A. M., Blackie, A., Zhang, C., Christensen, R., & Barrett, H. L. (2018) · Pregnancy Hypertension · doi:10.1016/j.preghy.2018.09.002 · Cited by 7 · see citing works
Ceglowski, P., Lehane, K., Chow, C., Pelecanos, A. M., Tognolini, A., & Eley, V. A. (2020) · Obesity · doi:10.1002/oby.22746 · Cited by 7 · see citing works
“However, it is increasingly appreciated as a significant problem in clinical practice (9,23-25).”
BackgroundAccuracy of non-invasive blood pressure measurements in obese patients
Arnold, A., & McNaughton, A. (2018) · British Journal of Nursing · doi:10.12968/bjon.2018.27.1.35 · Cited by 5 · see citing works
Vaughn, K., Skinner, M., Vaughn, V., Wayant, C., & Vassar, M. B. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001870 · Cited by 5 · see citing works
“Consensus Opinions 11 and 21 also cited the lowest scoring systematic reviews in reporting quality in PRISMA, Halm [30] and Narayan and Webb [36], respectively.”
BackgroundRecent Advances in Multidisciplinary Critical Care
Blot, S. I., Afonso, E., & Labeau, S. O. (2015) · American Journal of Critical Care · doi:10.4037/ajcc2015321 · Cited by 5 · see citing works
Aydın, V., Akıcı, A., Sakarya, S., Akman, M., & Fak, A. S. (2020) · TURKISH JOURNAL OF MEDICAL SCIENCES · doi:10.3906/sag-1907-144
“This is based on the fact that erroneous measurements due to mismatched cuff size in obese people, still a common practice, lead to overestimated readings and consequently unnecessary treatment [39].”
BackgroundKarnaukhov, V. V., Akishina, E. S., & Gerashchenko, S. M. (2023) · IEEE Ural-Siberian Conference on Computational Technologies in Cognitive Science, Genomics and Biomedicine (CSGB) · doi:10.1109/csgb60362.2023.10329861
“Several factors influence the accuracy of blood pressure measurements, including cuff parameters (e.g., cuff width and length) [2], biomechanical properties (e.g., elastic properties of the brachial artery wall) [3], and hemodynamic status of the cardiovascular system. e.g. mean blood pressure,…”
Background
- Authors
- Halm, M. A.
- Affiliations
- Salem Hospital (US)
- Corresponding author
- Halm, Margo A.
- ORCID
- Halm, Margo A.
- Venue
- American Journal of Critical Care
- Publisher
- AACN Publishing
- Published
- 2014-03-01
- Volume
- 23
- Issue
- 2
- Pages
- 166-170
- ISSN
- 1062-3264 (ISSN-L)
- 1937-710X
- OpenAlex
- W2151782327
- Cited by
- 15
- References
- 25
- Citations by year
- 2024: 2 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 2 · 2018: 5 · 2017: 1 · 2016: 1 · 2015: 1
- FWCI
- 0.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Critical Care (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- obesity, blood pressure measurement, cuff size, arm circumference, arm length
- MeSH terms
- Arm, Blood Pressure Determination, Diagnostic Errors, Humans, Obesity, Databases, Bibliographic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review