Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
Open accessAbstract
Introduction: Blood pressure measurements frequently guide management in critical care. Direct readings, commonly from a major artery, are considered to be the gold standard. Because arterial cannulation is associated with risks, alternative noninvasive blood pressure (NIBP) measurements are routinely used. However, the accuracy of NIBP determinations in overweight patients in the outpatient setting is variable, and little is known about critically ill patients. This prospective, observational study was performed to compare direct intra-arterial blood pressure (IABP) with NIBP measurements obtained using auscultatory and oscillometric methods in overweight patients admitted to our medical intensive care unit. Method: Adult critically ill patients with a body mass index (BMI) of 25 kg/m 2 or greater and a functional arterial line (assessed using the rapid flush test) were enrolled in the study. IABP measurements were compared with those obtained noninvasively. A calibrated aneroid manometer (auscultatory technique) with arm cuffs compatible with arm sizes and a NIBP monitor (oscillometric technique) were used for NIBP measurements. Agreement between methods was assessed using Bland-Altman analysis. Results: Fifty-four patients (23 males) with a mean (± standard error) age of 57 ± 3 years were studied. The mean BMI was 34.0 ± 1.4 kg/m 2. Mean arm circumference was 32 ± 0.6 cm. IABP readings were obtained from the radial artery in all patients. Only eight patients were receiving vasoactive medications. Mean overall biases for the auscultatory and oscillometric techniques were 4.1 ± 1.9 and -8.0 ± 1.7 mmHg, respectively (P < 0.0001), with wide limits of agreement. The overestimation of blood pressure using the auscultatory technique was more important in patients with a BMI of 30 kg/m 2 or greater. In hypertensive patients both NIBP methods underestimated blood pressure as determined using direct IABP measurement. Conclusion: Oscillometric blood pressure measurements underestimated IABP readings regardless of patient BMI. Auscultatory measurements were also inaccurate, tending to underestimate systolic blood pressure and overestimate mean arterial and diastolic blood pressure. NIBP can be inaccurate among overweight critically ill patients and lead to erroneous interpretations of blood pressure.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Specialist consultation appears to be associated with improved patient outcomes for a variety of infectious syndromes.
“Specialist consultation appears to be associated with improved patient outcomes for a variety of infectious syndromes (295-300).”
From Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021. (2021) · cites this paper as [299]
The Introduction and Discussion address blood-pressure monitoring in overweight critically ill patients, not specialist consultation. Searches for specialist consultation and infectious-disease consultation found no passage linking consultation to outcomes for infectious syndromes. Page numbers are unavailable in our copy. (LLM, conf=0.78)
Experimental — accuracy not yet measuredNon-invasive cuff blood pressure estimation tends to be inaccurate, with discrepancy more pronounced in shock states.
“Estimation of blood pressure using a non-invasive cuff tends to be inaccurate and the discrepancy more pronounced in shock states [375–379].”
From Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021 (2021) · cites this paper as [375]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985 · see citing works
Human blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C. M., Flack, J. M., Frohlich, E. D., Hill, M. D., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,592 · see citing works
Direct Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 522 · see citing works
Principles and techniques of blood pressure measurement.
Pickering, T. (2002) · Cardiology Clinics · doi:10.1016/s0733-8651(01)00009-1 · Cited by 299 · see citing works
Principles and techniques of blood pressure measurement
Ogedegbe, G., & Pickering, T. (2002) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 290 · see citing works
Marik, P. E., & Varón, J. (1998) · CHEST Journal · doi:10.1378/chest.113.2.492 · Cited by 289 · see citing works
Measuring Blood Pressure Accurately
Jones, D. W., Appel, L. J., Sheps, S. G., Roccella, E. J., & Lenfant, C. J. M. (2003) · JAMA · doi:10.1001/jama.289.8.1027 · Cited by 263 · see citing works
Bur, A., Hirschl, M. M., Herkner, H., Oschatz, E., Kofler, J., Woisetschläger, C., & Laggner, A. N. (2000) · Critical Care Medicine · doi:10.1097/00003246-200002000-00014 · Cited by 154 · see citing works
Bur, A., Herkner, H., Vlcek, M., Woisetschläger, C., Derhaschnig, U., Karth, G. D., Laggner, A. N., & Hirschl, M. M. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000053650.12025.1a · Cited by 121 · see citing works
Clinical Approach to the Critically Ill, Morbidly Obese Patient
El-Solh, A. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200309-1256cc · Cited by 98 · see citing works
What will replace the mercury sphygmomanometer?
Pickering, T. G. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200302000-00005 · Cited by 76 · see citing works
Measuring blood pressure: pitfalls and recommendations
Tholl, U., Forstner, K., & Anlauf, M. (2004) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfg602 · Cited by 76 · see citing works
Blood pressure measurement in research and in clinical practice: recent evidence
Parati, G., Bilo, G., & Mancia, G. (2004) · Current Opinion in Nephrology & Hypertension · doi:10.1097/00041552-200405000-00013 · Cited by 74 · see citing works
Accuracy of auscultatory blood pressure measurements in hypertensive and obese subjects.
Nielsen, P. E., Larsen, B., Holstein, P., & Poulsen, H. (1983) · Hypertension · doi:10.1161/01.hyp.5.1.122 · Cited by 50 · see citing works
An evaluation of a new continuous blood pressure monitoring system in critically ill patients
Heard, S. O., Lisbon, A., Tóth, I., & Ramasubramanian, R. (2000) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(00)00201-4 · Cited by 29 · see citing works
Biases in the measurement of arterial pressure
Keith, J. C., FINNIE, Watts, D. G., et al. (1984) · Critical Care Medicine · doi:10.1097/00003246-198411000-00009 · Cited by 23 · see citing works
Improved Accuracy of Indirect Blood Pressure Measurement in Patients With Obese Arms
Stolt, M., Sjönell, G., Åström, H., et al. (1993) · American Journal of Hypertension · doi:10.1093/ajh/6.1.66 · Cited by 19 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- Jones DW, Appel LJ, Sheps SG, Roccella EJ, Lenfant C: Measur- ing blood pressure accurately. New and persistent changes. JAMA 2003, 289:1027-1030.
Cited by
Sorted by citations
Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021.
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005337 · Cited by 2,935 · see citing works
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357 · see citing works
Methods of Blood Pressure Measurement in the ICU*
Lehman, L.-W. H., Saeed, M., Talmor, D., Mark, R., & Malhotra, A. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265ea46 · Cited by 224 · see citing works
Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06506-y · Cited by 5,082 · see citing works
Riley, L. E., Chen, G. J., & Latham, H. E. (2017) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000258 · Cited by 43 · see citing works
Kaur, B., Kaur, S., Yaddanapudi, L. N., & Singh, N. V. (2019) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000358 · Cited by 22 · see citing works
Halm, M. A. (2014) · American Journal of Critical Care · doi:10.4037/ajcc2014364 · Cited by 15 · see citing works
- Authors
- Araghi, A., Bander, J. J., & Guzman, J. A.
- Affiliations
- Wayne State University (US)
- Venue
- Critical Care
- Published
- 2006-04-19
- Volume
- 10
- Issue
- 2
- Pages
- R64-R64
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2158096939
- Cited by
- 115
- References
- 18
- Citations by year
- 2026: 1 · 2025: 8 · 2024: 2 · 2023: 6 · 2022: 8 · 2021: 6 · 2020: 5 · 2019: 3 · 2018: 8 · 2017: 7 · 2016: 5 · 2015: 9 · 2014: 9 · 2013: 7 · 2012: 10
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Critical Care (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Human Biology (submittedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- arterial pressure monitoring, non-invasive blood pressure measurement, intra-arterial blood pressure, overweight patients, obesity, critically ill patients, oscillometric blood pressure, auscultatory blood pressure, measurement accuracy, body mass index, arm circumference, radial artery
- MeSH terms
- Blood Pressure, Blood Pressure Determination, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Cohort Studies, Blood Pressure Monitors, Body Mass Index, Critical Illness, Overweight
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review