The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Monitoring Arterial Blood Pressure: What You May Not Know
Abstract
Arterial blood pressure (ABP), a basic hemodynamic index, is often used to guide therapeutic interventions in critically ill patients. Inaccurate ABP measuring may cause misdiagnosis and mismanagement. Because of a knowledge deficit related to hemodynamic and ABP monitoring, the authors discuss ABP physiology, factors that affect ABP, and the arterial pressure waveform and its interpretation in clinical situations.Arterial blood pressure (ABP) is a basic hemodynamic index often utilized to guide therapeutic interventions, especially in critically ill patients. Inaccurate ABP measuring creates a potential for misdiagnosis and mismanagement. The results of a recent pilot study1 at 2 university-affiliated hospitals suggested a knowledge deficit in arterial pressure monitoring and some of the most basic aspects of hemodynamic monitoring. A total of 391 critical care nurses practicing in various critical care specialties were invited to participate in the study. The response rate was 17.4% (n = 68). Most of the participants were between the ages of 30 and 39 years (56.1%) and had a baccalaureate degree as their basic (61.8%) and highest degree in nursing (58.8%). Most participants had more than 4 years of nursing experience (94.1%) and critical care experience (83.9%), and most did direct ABP monitoring at least once or twice each week (97.1%). The participants were asked to complete an 18-item, criterion-referenced questionnaire on ABP physiology, technical aspects of ABP monitoring, and ABP waveform interpretation in selected pathophysiological conditions. The mean score in this pilot study was 36.7% (SD, 11.8%). Total scores ranged from 11.1% to 61.1%.Literature on nurses’ knowledge of hemodynamic monitoring is limited, but several studies,2–5 published and unpublished, indicate a general knowledge deficit in pulmonary artery pressure monitoring. Because of these research findings, in this article, we focus on areas of particular knowledge deficit related to essential principles of hemodynamic monitoring and ABP monitoring. We discuss the physiology of ABP, physiological and pathophysiological factors that affect ABP, and the arterial pressure waveform and its interpretation in clinical situations common in critical care patients.The cardiovascular system has 3 types of pressures6,7: hemodynamic, kinetic energy, and hydrostatic. Hemodynamic pressure is the energy imparted to the blood by contraction of the left ventricle. This type of pressure is preserved by the elastic properties of the arterial system. Kinetic energy is the energy associated with motion and affects the pressure measured during direct ABP monitoring. Fluid density and gravity contribute to hydrostatic pressure, which is the pressure a column of fluid exerts on the container wall. For example, in a column of fluid, the pressure at a given level in the container is proportional to the height of the fluid column above that level. The pressure is highest at the bottom of the column. In the vascular system, hydrostatic pressure is proportional to the height of the column of blood between the heart and the peripheral vasculature. In a standing person, the pressure in the leg is higher than the pressure in the arm by the difference in hydrostatic pressure. In summary, arterial blood pressure represents the force exerted by the blood per unit area on the arterial wall6–8 and is the sum of hemodynamic, kinetic, and hydrostatic pressure.The arterial tree starts with the aorta and the major branches of this vessel. The aorta and its branches stretch to receive blood from the left ventricle and recoil to distribute the blood and to maintain arterial pressure. Arteries and arterioles control blood pressure through vasoconstriction or vasodilation.6 Arterioles are the primary sites that contribute to systemic vascular resistance (SVR).6,9–11 In addition, adrenergic control of the arterioles is a major determinant of blood flow into the capillaries. In the skin, for instance, blood can be shunted from the capillary beds to flow directly from arterioles into the venous system.9 Arteriovenous shunting occurs in shock states and helps to redirect blood flow to vital organs. Arteriovenous shunting is one reason measurements of blood pressure alone are not a good indicator of peripheral tissue perfusion.Arterial pressure is measured at its peak, which is the systolic blood pressure (SBP), and at its trough, which is the diastolic blood pressure (DBP). The SBP is determined by the stroke volume, the velocity of left ventricular ejection (an indirect indicator of left ventricular contractile force), systemic arterial resistance, the distensibility of the aortic and arterial walls, the viscosity of blood, and the left ventricular preload (end-diastolic volume).11–13 The blood pressure in the aorta during systole is a clinical indicator of afterload (the sum of the forces the left ventricle must overcome to eject blood).14,15 The diastolic pressure is affected by
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hemodynamic Patterns of Age-Related Changes in Blood Pressure: The Framingham Heart Study
Franklin, S. S., Gustin, W., Wong, N. D., Larson, M. G., Weber, M. A., Kannel, W. B., & Levy, D. (1997) · Circulation · doi:10.1161/01.cir.96.1.308 · Cited by 2,321
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“Catheterization is the gold standard method [6].”
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Wu, Q., Qiao, Y., Guo, R., Naveed, S., Hirtz, T., Li, X., Fu, Y., Wei, Y., Deng, G., Yang, Y., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c03294 · Cited by 276
Piezoelectric Dynamics of Arterial Pulse for Wearable Continuous Blood Pressure Monitoring
Yi, Z., Liu, Z., Li, W., Ruan, T., Chen, X., Liu, J., Yang, B., & Zhang, W. (2022) · Advanced Materials · doi:10.1002/adma.202110291 · Cited by 265
Methods of Blood Pressure Measurement in the ICU*
Lehman, L.-W. H., Saeed, M., Talmor, D., Mark, R., & Malhotra, A. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265ea46 · Cited by 224
Metadata
- Authors
- McGhee, B. H., & Bridges, E. J.
- Venue
- Critical Care Nurse
- Publisher
- AACN Publishing
- Published
- 2002-04-01
- Volume
- 22
- Issue
- 2
- Pages
- 60-79
- ISSN
- 0279-5442 (ISSN-L)
- 1940-8250
- OpenAlex
- W2139210766
- Cited by
- 189
- References
- 1
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring Arterial Blood Pressure: What You May Not Know. https://app.cochat.ai/papers/10.4037/ccn2002.22.2.60
- The paper
- McGhee, B. H., & Bridges, E. J. (2002). Monitoring Arterial Blood Pressure: What You May Not Know. Critical Care Nurse. https://doi.org/10.4037/ccn2002.22.2.60
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.