CoChat

Development and Validation of Deep-Learning Algorithm for Electrocardiography-Based Heart Failure Identification

Open access
Kwon, Joon-myoung, Kim, Kyung-Hee, Jeon, Ki-Hyun, Kim, Hyue Mee, Kim, Min Jeong, Lim, Sung-Min, Song, Pil Sang, Park, Jinsik, Choi, Rak Kyeong, Oh, Byung-Hee · 2019 · Korean Circulation Journal
Cited by 133

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND OBJECTIVES: Screening and early diagnosis for heart failure (HF) are critical. However, conventional screening diagnostic methods have limitations, and electrocardiography (ECG)-based HF identification may be helpful. This study aimed to develop and validate a deep-learning algorithm for ECG-based HF identification (DEHF). METHODS: The study involved 2 hospitals and 55,163 ECGs of 22,765 patients who performed echocardiography within 4 weeks were study subjects. ECGs were divided into derivation and validation data. Demographic and ECG features were used as predictive variables. The primary endpoint was detection of HF with reduced ejection fraction (HFrEF; ejection fraction [EF]≤40%), and the secondary endpoint was HF with mid-range to reduced EF (≤50%). We developed the DEHF using derivation data and the algorithm representing the risk of HF between 0 and 1. We confirmed accuracy and compared logistic regression (LR) and random forest (RF) analyses using validation data. RESULTS: The area under the receiver operating characteristic curves (AUROCs) of DEHF for identification of HFrEF were 0.843 (95% confidence interval, 0.840-0.845) and 0.889 (0.887-0.891) for internal and external validation, respectively, and these results significantly outperformed those of LR (0.800 [0.797-0.803], 0.847 [0.844-0.850]) and RF (0.807 [0.804-0.810], 0.853 [0.850-0.855]) analyses. The AUROCs of deep learning for identification of the secondary endpoint was 0.821 (0.819-0.823) and 0.850 (0.848-0.852) for internal and external validation, respectively, and these results significantly outperformed those of LR and RF. CONCLUSIONS: The deep-learning algorithm accurately identified HF using ECG features and outperformed other machine-learning methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4070/kcj.2018.0446

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 133

Metadata

Authors
Kwon, J.-M., Kim, K.-H., Jeon, K.-H., Kim, H. M., Kim, M. J., Lim, S.-M., Song, P. S., Park, J., Choi, R. K., & Oh, B.-H.
Venue
Korean Circulation Journal
Publisher
XMLink
Published
2019
Volume
49
Issue
7
Pages
629
ISSN
  • 1225-164X (ISSN-L)
  • 1738-5520
  • 1738-5555
OpenAlex
W2946751363
Cited by
133
References
7
FWCI
8.31
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and Validation of Deep-Learning Algorithm for Electrocardiography-Based Heart Failure Identification. https://app.cochat.ai/papers/10.4070/kcj.2018.0446
The paper
Kwon, J.-M., Kim, K.-H., Jeon, K.-H., Kim, H. M., Kim, M. J., Lim, S.-M., Song, P. S., Park, J., Choi, R. K., & Oh, B.-H. (2019). Development and Validation of Deep-Learning Algorithm for Electrocardiography-Based Heart Failure Identification. Korean Circulation Journal. https://doi.org/10.4070/kcj.2018.0446

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.