RSSDI-ESI clinical practice recommendations for the management of type 2 diabetes mellitus 2020
Open accessThe DOI matches its Crossref record; 188 of the 188 references it cites were found in a registry or an index.
Abstract
DIAGNOSIS OF DIABETES RECOMMENDATIONSTable: No title available.Table: No title available.NOTE Estimation of HbA1c should be performed using NGSP standardized method. Capillar y glucose estimation methods are not recommended for diagnosis Venous plasma is used for estimation of glucose Plasma must be separated soon after collection because the blood glucose levels drop by 5%–8% hourly if whole blood is stored at room temperature. For more details on glucose estimation visit: http://www.ncbi.nlm.nih.gov/books/NBK248/ *FPG is defined as glucose estimated after no caloric intake for at least 8–12 hours. **Using a method that is National Glycohaemoglobin Standardization Program (NGSP) certified. For more on HbA1c and NGSP, please visit http://www.ngsp.org/index.asp BACKGROUND The diagnostic criteria of diabetes have been constantly evolving. Both type 1 and type 2 Diabetes mellitus (DM) are diagnosed based on the plasma glucose criteria, either the fasting plasma glucose (FPG) levels or the 2-h plasma post-prandial glucose (2-h PPG) levels during a 75-g oral glucose tolerance test (OGTT), or the newer glycosylated haemoglobin (HbA1c) criteria which reflects the average plasma glucose concentration over the previous 8–12 weeks.[12] The International Expert Committee Report recommend a cut-point of ≥6.5% for HbA1c for diagnosing diabetes as an alternative to fasting plasma glucose (FPG ≥7.0 mmol/L).[3] HbA1c testing has some substantial advantages over FPG and OGTT, such as convenience, pre-analytical stability, and less day-to-day fluctuations due to stress and illness.[3] Additionally, HbA1c has been recognized as marker to assess secondary vascular complications due to metabolic derailments in susceptible individuals.[245] However, given ethnic differences in sensitivity and specificity of HbA1c population-specific cut-offs might be necessary.[67] Moreover, measuring HbA1c is expensive as compared to FPG assessments and standardization of measurement techniques and laboratories are poorly practiced across the country.[8] Also, in several countries including India, HbA1c demonstrated inadequate predictive accuracy in the diagnosis of diabetes, there is no consensus on a suitable cut-off point of HbA1c for diagnosis of diabetes in this high-risk population.[9] In lieu of this, the panel expressed concerns on using HbA1c as sole criteria for diagnosis of diabetes particularly in resource constraint settings. Therefore, a combination of HbA1cand FPG would improve the identification of individuals with diabetes mellitus and prediabetes in limited resource settings like India. CONSIDERATIONS The decision about setting diagnostic thresholds values was based on the cost-effective strategies for diagnosing diabetes that were reviewed in Indian context. RATIONALE AND EVIDENCE Glycosylated haemoglobin cut off for diagnosis of diabetes in Indian patients The RSSDI expert panel suggests [WHITE SMALL SQUAREHbA1c ≥6.5% as optimal level for diagnosis of diabetes in Indian patients [WHITE SMALL SQUAREHbA1c cannot be used as 'sole' measurement for diagnosis of diabetes in Indian settings. These recommendations are based on the Indian evidences A recent study conducted in Singapore residents of Chinese, Malay and Indian race to assess the performance of HbA1c as a screening test in Asian populations suggested that HbA1c is an appropriate alternative to FPG as a first-step screening test, and a combination of HbA1c with a cut-off of ≥6.1% and FPG level ≥100 mg/dL would improve detection in patients with diabetes.[6] A study to assess the diagnostic accuracy and optimal HbA1c cutoffs for diabetes and prediabetes among high-risk south Indians suggested that HbA1c ≥6.5% can be defined as a cut-off for diabetes and HbA1c ≥5.9% is optimal for prediabetes diagnosis and value <5.6% excludes prediabetes/diabetes status.[8] Data from a community based randomized cross sectional study in urban Chandigarh suggest that HbA1c cut point of 6.5% has optimal specificity of 88%, while cut off point of 7.0% has sensitivity of 92% for diagnosis of diabetes.[10] The results of the Chennai Urban Rural Epidemiology Study (CURES) demonstrated 88.0% sensitivity and 87.9% specificity for detection of diabetes when HbA1c cut off point is 6.1% (based on 2-h post load plasma glucose) and 93.3% sensitivity and 92.3% specificity when HbA1c cut off point is 6.4% (when diabetes was defined as FPG ≥7.0 mmol/l).[11] However, panel emphasized that HbA1c can be used in settings where an appropriate standardized method is available. IMPLEMENTATION Individuals should be educated on the advantages of early diagnosis and should be encouraged to participate in community screening programs for diagnosis. PREVENTION RECOMMENDATIONSTable: No title available.Table: No title available.BACKGROUND Chronic hyperglycaemia is associated with significantly higher risk of developing diabetes related micro-and macrovascular complications. Early detection of diabetes/prediabetes throu
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
A comprehensive review on metabolic syndrome
Kaur, J. (2014) · Cardiology Research and Practice · doi:10.1155/2014/943162 · Cited by 1,889
RetractedEmpagliflozin, Cardiovascular Outcomes, and Mortality in Type 2 Diabetes
Zinman, B., Wanner, C., Lachin, J. M., Fitchett, D., Bluhmki, E., Hantel, S., Mattheus, M., Devins, T., Johansen, O. E., Woerle, H. J., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1504720 · Cited by 12,315
Yusuf, S., Hawken, S., Ôunpuu, S., Dans, T., Avezum, A., Lanas, F., McQueen, M., Budaj, A., Pais, P., Varigos, J., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17018-9 · Cited by 12,026
European Guidelines on cardiovascular disease prevention in clinical practice (version 2012)
Authors/Task Force Members:, Perk, J., De Backer, G., Gohlke, H., Graham, I., Reiner, Ž., Verschuren, M., Albus, C., Benlian, P., Boysen, G., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs092 · Cited by 8,490
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Canagliflozin and Cardiovascular and Renal Events in Type 2 Diabetes
Neal, B., Perkovic, V., Mahaffey, K. W., de Zeeuw, D., Fulcher, G., Erondu, N., Shaw, W., Law, G., Desai, M., & Matthews, D. R. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1611925 · Cited by 7,830
10-year follow-up of intensive glucose control in type 2 diabetes
Holman, R. R., Paul, S. K., Bethel, M. A., Matthews, D. R., & Neil, H. A. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806470 · Cited by 7,751 · cited 2×
“in terms of reduced diabetes-related endpoints, diabetesrelated deaths, and all-cause mortality.[169] Along with”
BackgroundLiraglutide and Cardiovascular Outcomes in Type 2 Diabetes
Marso, S. P., Daniels, G. H., Brown-Frandsen, K., Kristensen, P., Mann, J. F. E., Nauck, M. A., Nissen, S. E., Pocock, S., Poulter, N. R., Ravn, L. S., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1603827 · Cited by 7,629 · cited 72×
“[184] TZDs have demonstrated beneficial effects in attenuating dyslipidaemia commonly observed in patients with chronic T2DM.”
BackgroundInfluentialSemaglutide and Cardiovascular Outcomes in Patients with Type 2 Diabetes
Marso, S. P., Bain, S. C., Consoli, A., Eliaschewitz, F. G., Jódar, E., Leiter, L. A., Lingvay, I., Rosenstock, J., Seufert, J., Warren, M. L., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1607141 · Cited by 6,900
Cited by
Evaluation of the performance and usability of a novel continuous glucose monitoring system
Yan, L., Li, Q., Guan, Q., Han, M., Zhao, Y., Fang, J., & Zhao, J. (2023) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-022-01112-0 · Cited by 13
Metadata
- Authors
- Madhu, S., Chawla, R., Makkar, B., Ghosh, S., Saboo, B., & Kalra, S.
- Venue
- Indian Journal of Endocrinology and Metabolism
- Publisher
- Medknow
- Published
- 2020
- Volume
- 24
- Issue
- 1
- Pages
- 1
- ISSN
- 2230-8210 (ISSN-L)
- OpenAlex
- W3023689184
- Cited by
- 167
- References
- 188
- FWCI
- 17.20
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.