CoChat

Validation of the sulphur hexafluoride (SF6) tracer gas technique for measurement of methane and carbon dioxide production by cattle

Boadi, D. A., Wittenberg, K. M., Kennedy, A. D. · 2002 · Canadian Journal of Animal Science
Cited by 90

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Methane (CH 4) and carbon dioxide (CO 2) production from six crossbred yearling beef heifers (400 ± 13.0 kg) were measured, using the sulphur hexafluoride (SF 6) tracer gas technique (Tracer) and open-circuit hood calorimetry (Cal) to validate the former in estimating rumen CH 4 and CO 2 production in the field. Animals were individually fed a diet consisting of 50% barley concentrate and 50% alfalfa cubes at 1.3 × ;maintenance requirements daily. Hifers were divided into two groups for individual animal 24- h gas measurements by each method. Each group of heifers was rotated between the Cal and Tracer techniques for 6 consecutive days in an incomplete block design. Methane production ranged from 108 to 145 L d-1 (mean 130 ± 4.0 L d-1) using the Cal technique, and 90 to 167 L d-1 (mean 137 ± 4.0 L d-1) using the Tracer technique. The mean CH 4 production (L d-1) was not different (P = 0.24) between the two methods. Carbon dioxide production with the Tracer technique was 20% higher than CO 2 production with the Cal technique (P < 0.01). The range of CO 2 production was 1574 to 2049 L d-1 (mean 1892 ± 74.0 L d-1) by Cal, and 1541 to 3330 L d-1 (mean 2353 ± 74.0 L d-1) by Tracer. Day-to-day variation in CH 4 production was not different within each method (P > 0.05); however, animal-to-animal variation (11.7%) was significant for the Tracer technique (P = 0.04), but not for the Cal technique (P = 0.53). Comparison of the equality of variance between the two methods showed that there were no differences in variations (P > 0.05) between Cal and Tracer for CH 4 production. On the other hand, variations in CO 2 production were not equal (P > 0.05) between methods. Day-to-day variation in CO 2 production was significant using Cal, but not Tracer (P > 0.05). Animal-to-animal variation in CO 2 production was 1.6 and 11.8% by Cal and Tracer techniques, respectively. It can be concluded that the SF 6 tracer technique accurately estimated rumen CH 4 production, but CO 2 production was 20% higher. The study suggests that for CH 4 measurements using the SF 6 tracer technique, more animal numbers are needed than for Cal to reduce animal-to-animal variation. Key words: Methane, carbon dioxide, SF 6 tracer technique, validation, cattle

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4141/a01-054

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 90

Metadata

Authors
Boadi, D. A., Wittenberg, K. M., & Kennedy, A. D.
Venue
Canadian Journal of Animal Science
Published
2002-06-01
Volume
82
Issue
2
Pages
125-131
ISSN
  • 0008-3984 (ISSN-L)
  • 1918-1825
OpenAlex
W2075741877
Cited by
90
References
1
FWCI
4.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.