Validation of a heart-rate monitor for measuring a stress response in dairy cows
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In three experiments, a commercial non-invasive heart-rate monitor, Polar® Sport Tester (PST), was validated for use with dairy cows. First, 10 monitors were tested using a pulse generator, which produced pulses at levels between 30 and 240 bpm. PST values and generated beats were highly correlated (r = 0.97) but with varying delay (5–55 s), depending on pulse-rate level.In a second experiment, 10 dairy cows were quietly standing or exercising on a treadmill while their heart rates were recorded by direct-wire electrocardiograph (ECG) as well as the PST. Correlations between ECG and PST values during standing (0.88) and exercising (0.72) were significant and differed between cows. During standing, inter-beat interval and PST standard deviations were significantly correlated (R sp = 0.76), as were their coefficients of variation (R sp = 0.89).The third experiment showed that the heart rate of 10 dairy cows increased rapidly immediately after an individual was isolated from the herd. Cows showed no obvious signs of being hampered by the equipment during the 1-h trials.Change in heart rate may be a relevant parameter for studying an animal's response to a stressor. As heart-rate variability is thought to serve as an important mechanism for adaptability in humans, this aspect needs further attention in farm animals. The PST is suitable for measuring both heart rate and heart-rate variability in dairy cows. Key words: Heart rate, dairy cows, stress, treadmill
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vagal Tone: A Physiologic Marker of Stress Vulnerability
Porges, S. W. (1992) · Pediatrics · doi:10.1542/peds.90.3.498 · Cited by 541
Cited by
von Borell, E., Langbein, J., Després, G., Hansen, S., Leterrier, C., Marchant, J., Marchant-Forde, R., Minero, M., Mohr, E., Prunier, A., et al. (2007) · Physiology & Behavior · doi:10.1016/j.physbeh.2007.01.007 · Cited by 974
Behavioral, Cardiac and Cortisol Responses to Brief Peer Separation and Reunion in Cattle
Boissy, A., & Le Neindre, P. (1997) · Physiology & Behavior · doi:10.1016/s0031-9384(96)00521-5 · Cited by 272
Van Reenen, C. G., O'Connell, N. E., Van der Werf, J. T. N., Korte, S. M., Hopster, H., Jones, R. B., & Blokhuis, H. J. (2005) · Physiology & Behavior · doi:10.1016/j.physbeh.2005.06.015 · Cited by 163
Self-citationShamsoddini, A., Sobhani, V., Ghamar Chehreh, M. E., Alavian, S. M., & Zaree, A. (2015) · Hepatitis Monthly · doi:10.5812/hepatmon.31434 · Cited by 126
“To assure that the desired heart rate (exercise intensity) was achieved and maintained for 30 minute, during the aerobic sessions, each participant underwent heart-rate monitoring with polar (model: FT1) heart rate monitor (24).”
MethodArtificial eggs: Measuring heart rate and effects of disturbance in nesting penguins
Nimon, A. J., Schroter, R. C., & Oxenham, R. K. C. (1996) · Physiology & Behavior · doi:10.1016/0031-9384(96)00079-0 · Cited by 63
(1996) · Cited by 2
Metadata
- Authors
- Hopster, H., & Blokhuis, H. J.
- Venue
- Canadian Journal of Animal Science
- Publisher
- Canadian Science Publishing
- Published
- 1994-09-01
- Volume
- 74
- Issue
- 3
- Pages
- 465-474
- ISSN
- 0008-3984 (ISSN-L)
- 1918-1825
- OpenAlex
- W2037256934
- Cited by
- 149
- References
- 1
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.