Cited by 35Clinical Laboratory Practices and Quality ControlOvarian function and disordersHormonal and reproductive studies

Utilization of commercial laboratory results in management of hyperandrogenism in women

Steinberger, Emil, Ayala, Carma, Hsi, Bartholomew, Smith, Keith D., Rodriguez-Rigau, Luis J., Weidman, E. Russell, Reimondo, Gerold G.·1998·Endocrine Practice

Abstract

Objective To compare results from testosterone radioimmunoassay kits commonly used by commercial laboratories as well as their reference ranges and to analyze the scientific literature for ranges of serum testosterone levels in normal women and those with hyperandrogenism.Methods We reviewed quality assurance reports of various testosterone ligand challenges from four groups of laboratories and summarized testosterone data from 17 published reports about normal women and 14 studies of hyperandrogenic women.Results A significant variability was demonstrated between the radioimmunoassay kits at all concentrations (for example, a sample with a mean testosterone level of 96.1 ng/dL was reported by some laboratories as containing 71.8 ng/dL and by others as 123.4 ng/dL). All laboratories provide essentially the same "reference range" (approximately 10 to 90 ng/dL) but do not report how the range was established. The scientific literature clearly shows a significant separation in serum testosterone levels between normal (that is, not hyperandrogenic) and hyperandrogenic women. Most hyperandrogenic women had testosterone levels >50 ng/dL, whereas most normal control subjects had levels <40 ng/dL. Thus, most of these women with hyperandrogenism would have been considered to have normal testosterone levels if the reference ranges of commercial laboratories were used.Conclusion These data illustrate the difficulty that physicians face when they are required to use different commercial laboratories to measure serum testosterone levels. We propose that (1) reference ranges be established on a clinically defined population for each hormone and method used, (2) laboratory reports include information about method and reference range population, and (3) physicians be allowed to choose which laboratories are used for their patients' hormone determinations, for consistency of results.

Integrity signals

Registry

Crossref · 10.4158/ep.4.1.1

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Steinberger, E., Ayala, C., Hsi, B., Smith, K. D., Rodriguez-Rigau, L. J., Weidman, E. R., & Reimondo, G. G.
Affiliations
The University of Texas Health Science Center at Houston (US)
Corresponding author
Steinberger, Emil
Venue
Endocrine Practice
Publisher
Elsevier BV
Published
1998-01
Volume
4
Issue
1
Pages
1-10
ISSN
1530-891X (ISSN-L)
OpenAlex
W2076369526
Cited by
35
References
36
Citations by year
2023: 1 · 2022: 1 · 2020: 1 · 2019: 3 · 2017: 2 · 2016: 3 · 2015: 5 · 2014: 1 · 2013: 2 · 2012: 1
FWCI
1.27
Type
journal article
Language
en
Open access
closed
Locations
  • Endocrine Practice (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Reproductive Medicine › Ovarian function and disorders
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hormonal and reproductive studies
Keywords
hyperandrogenism, serum testosterone, assay variability, laboratory quality assurance, women

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review