The DOI matches its Crossref record; 20 of the 21 references it cites were found in a registry or an index.
Confirmation of Hypoglycemia in the “Dead-In-Bed” Syndrome, as Captured by a Retrospective Continuous Glucose Monitoring System
Abstract
Objective To report a case that substantiates the presence of hypoglycemia at the time of death of a young man with type 1 diabetes, who was found unresponsive in his undisturbed bed in the morning.Methods We describe a 23-year-old man with a history of type 1 diabetes treated with an insulin pump, who had recurrent severe hypoglycemia. In an effort to understand these episodes better and attempt to eliminate them, a retrospective (non-real-time) continuous subcutaneous glucose monitoring system (CGMS) was attached to the patient. He was found dead in his undisturbed bed 20 hours later. The insulin pump and CGMS were both downloaded for postmortem study.Results Postmortem download of the data in the CGMS demonstrated glucose levels below 30 mg/dL around the time of his death, with only a minimal counter-regulatory response. This finding corresponded to a postmortem vitreous humor glucose of 25 mg/dL. An autopsy showed no major anatomic abnormalities that could have contributed to his death.Conclusion To our knowledge, this is the first documentation of hypoglycemia at the time of death in a patient with the "dead-in-bed" syndrome. This report should raise the awareness of physicians to the potentially lethal effects of hypoglycemia and provide justification for efforts directed at avoiding nocturnal hypoglycemia.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A temporal relationship between extremely low subcutaneous glucose concentrations and death in a patient with type 1 diabetes who was wearing a CGM device and was found dead in bed has been reported (31).”
From Hypoglycemia and Diabetes: A Report of a Workgroup of the American Diabetes Association and The Endocrine Society (2013) · cites this paper as [31]
In the citing paper
“A temporal relationship between extremely low subcutaneous glucose concentrations and death in a patient with type 1 diabetes who was wearing a CGM device and was found dead in bed has been reported (31).”
From Hypoglycemia and Diabetes: A Report of a Workgroup of the American Diabetes Association and The Endocrine Society (2013) · cites this paper as [31]
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Standards of medical care in diabetes—2011
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s011 · Cited by 2,880
Standards of Medical Care in Diabetes—2009
American Diabetes Association (2009) · Diabetes Care · doi:10.2337/dc09-s013 · Cited by 2,167
Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes.
Cryer, P. (2002) · Diabetologia · doi:10.1007/s00125-002-0822-9 · Cited by 794
Frequency of Severe Hypoglycemia Requiring Emergency Treatment in Type 1 and Type 2 Diabetes
Leese, G. P., Wang, J., Broomhall, J., Kelly, P., Marsden, A., Morrison, W., Frier, B. M., Morris, A. D., & For the DARTS/MEMO Collaboration (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1176 · Cited by 559
Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor
Garg, S. K., Zisser, H., Schwartz, S. L., Bailey, T. S., Kaplan, R. A., Ellis, S. L., & Jovanovič, L. (2006) · Diabetes Care · doi:10.2337/diacare.29.01.06.dc05-1686 · Cited by 429
Diverse causes of hypoglycemia-associated autonomic failure in diabetes.
Cryer, P. E. (2004) · New England Journal of Medicine · doi:10.1056/nejmra031354 · Cited by 411
Unexplained Deaths of Type 1 Diabetic Patients
Tattersall, R. B., & Gill, G. V. (1991) · Diabetic Medicine · doi:10.1111/j.1464-5491.1991.tb01516.x · Cited by 308
Mechanisms of abnormal cardiac repolarization during insulin-induced hypoglycemia
Robinson, R. T. C. E., Harris, N. D., Ireland, R. H., Lee, S., Newman, C., & Heller, S. R. (2003) · Diabetes · doi:10.2337/diabetes.52.6.1469 · Cited by 264
Duration of Nocturnal Hypoglycemia Before Seizures
Buckingham, B. A., Wilson, D. M., Lecher, T., Hanås, R., Kaiserman, K. B., & Cameron, F. J. (2008) · Diabetes Care · doi:10.2337/dc08-0863 · Cited by 111
Nocturnal Hypoglycemia: Clinical Manifestations and Therapeutic Strategies Toward Prevention
Allen, K. V., & Frier, B. M. (2003) · Endocrine Practice · doi:10.4158/ep.9.6.530 · Cited by 93
Dead in Bed Syndrome in Young Diabetic Patients in Norway
Thordarson, H. B., & Søvik, O. (1995) · Diabetic Medicine · doi:10.1111/j.1464-5491.1995.tb02080.x · Cited by 87
Abnormalities of the electrocardiogram during hypoglycaemia: the cause of the dead in bed syndrome?
Heller, S. R. (2002) · PubMed · Cited by 73
Sudden death in type 1 diabetes
McNally, P. G., Lawrence, I. G., Panerai, R. B., Weston, P. J., & Thurston, H. (1999) · Diabetes Obesity and Metabolism · doi:10.1046/j.1463-1326.1999.00025.x · Cited by 49
Sudden Death and Human Insulin: Is There a Link?
Borch‐Johnsen, K., & Helweg‐Larsen, K. (1993) · Diabetic Medicine · doi:10.1111/j.1464-5491.1993.tb00053.x · Cited by 39
‘Dead-in-bed’ syndrome - a diabetes nightmare
Koltin, D., & Daneman, D. (2008) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00404.x · Cited by 32
Tupola, S. J., Rajantie, J., & Åkerblom, H. K. (1998) · European Journal of Pediatrics · doi:10.1007/s004310050899 · Cited by 32
Sudden death in young patients with Type 1 diabetes: a consequence of disease, treatment or both?
Harris, N. D., & Heller, S. R. (1999) · Diabetic Medicine · doi:10.1046/j.1464-5491.1999.00046.x · Cited by 29
Nyström, L., Östman, J., Wall, S., Wibell, L. B., & The Diabetes Incidence Study in Sweden (DISS) Group (1992) · Diabetic Medicine · doi:10.1111/j.1464-5491.1992.tb01811.x · Cited by 23
‘Dead in bed syndrome – a hypothesis’
Bell, D. S. H. (2005) · Diabetes Obesity and Metabolism · doi:10.1111/j.1463-1326.2005.00511.x · Cited by 21
Research works printed but not linked: 1
- Søvick, 1999, Dead in bed syndrome in young diabetic patients [published correction appears in Diabetes Care. 1999;22:1389], Diabetes Care, 22, B40
Cited by
Sorted by citations
Physical activity/exercise and diabetes: A position statement of the American Diabetes Association
Colberg, S. R., Sigal, R. J., Yardley, J. E., Riddell, M. C., Dunstan, D. W., Dempsey, P. C., Horton, E. S., Castorino, K., & Tate, D. F. (2016) · Diabetes Care · doi:10.2337/dc16-1728 · Cited by 2,991
2023 ESC guidelines for the management of cardiovascular disease in patients with diabetes.
Marx, N., Federici, M., Schütt, K., Müller-Wieland, D., Ajjan, R. A., Antunes, M. J., Christodorescu, R. M., Crawford, C., Di Angelantonio, E., Eliasson, B., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad192 · Cited by 1,642
Seaquist, E. R., Anderson, J., Childs, B., Cryer, P., Dagogo-Jack, S., Fish, L., Heller, S. R., Rodriguez, H., Rosenzweig, J., & Vigersky, R. (2013) · Diabetes Care · doi:10.2337/dc12-2480 · Cited by 1,389
“A temporal relationship between extremely low subcutaneous glucose concentrations and death in a patient with type 1 diabetes who was wearing a CGM device and was found dead in bed has been reported (31).”
BackgroundExercise management in type 1 diabetes: a consensus statement
Riddell, M. C., Gallen, I. W., Smart, C. E., Taplin, C. E., Adolfsson, P., Lumb, A. N., Kowalski, A., Rabasa-Lhoret, R., McCrimmon, R. J., Hume, C., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30014-1 · Cited by 903
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Metadata
- Authors
- Tanenberg, R. J., Newton, C. A., & Drake, A. J.
- Affiliations
- East Carolina University (US)
- Emory University (US)
- Corresponding author
- Tanenberg, Robert J.
- ORCID
- Tanenberg, Robert J.
- Venue
- Endocrine Practice
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 16
- Issue
- 2
- Pages
- 244-248
- ISSN
- 1530-891X (ISSN-L)
- OpenAlex
- W1994810473
- Cited by
- 225
- References
- 21
- Citations by year
- 2026: 6 · 2025: 7 · 2024: 8 · 2023: 15 · 2022: 13 · 2021: 9 · 2020: 11 · 2019: 13 · 2018: 18 · 2017: 21 · 2016: 10 · 2015: 21 · 2014: 16 · 2013: 29 · 2012: 11
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Endocrine Practice (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Pathology and Forensic Medicine › Autopsy Techniques and Outcomes
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Keywords
- type 1 diabetes, continuous glucose monitoring, insulin pump therapy, nocturnal hypoglycemia, counterregulatory response
- MeSH terms
- Adult, Blood Glucose, Diabetes Mellitus, Type 1, Humans, Hypoglycemia, Insulin Infusion Systems, Male, Fatal Outcome, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review