Cited by 56Diabetes Management and ResearchDiabetes Treatment and ManagementIntravenous Infusion Technology and Safety

Comparison of pharmacokinetic properties, physicochemical stability, and pump compatibility of 3 rapid-acting insulin analogues— aspart, lispro, and glulisine

Bode, Bruce W.·2011·Endocrine Practice

Abstract

Objective To compare how the rapid-acting insulin analogues (RAIAs) aspart, lispro, and glulisine perform in continuous subcutaneous insulin infusion (CSII) therapy regarding (1) pharmacokinetic properties, (2) chemical and physical stability, and (3) pump compatibility. Methods PubMed was searched for articles pertaining to the use of RAIAs in CSII, without a restriction on the time period. Results These RAIAs have pharmacokinetic profiles that more closely mimic endogenous insulin in comparison with regular human insulin and tend to produce less hypoglycemia. Among these RAIAs, the rates of absorption and clinical efficacy in terms of glycemic control were similar. Although glulisine showed a faster onset of action in some studies with aspart and lispro, this advantage lasted only for a maximum of 1 hour, after which results were similar for glulisine and aspart or lispro. Each RAIA is created by making minor amino acid substitutions to the regular human insulin molecule and adding a stabilizer to help prevent fibrillation. A series of chemical and covalent changes affecting the primary structure of an insulin preparation, however, may cause decomposition during storage, handling, and use, diminishing the potency of the insulin molecule while contained in an insulin pump. Precipitation, fibrillation, and occlusion may ensue, undermining compatibility for CSII pump use. Aspart has demonstrated the greatest chemical and physical stability in the insulin pump, with the lowest…

Integrity signals

Registry

Crossref · 10.4158/ep10260.ra

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In a study of 59 subjects with type 1 diabetes receiving either ASP or insulin glulisine (GLU) via insulin pump for 16 weeks, the median catheter occlusion rate was low for both GLU and ASP (0 [0-0.7] vs 0 [0-1.1] occlusions/month).

    “In a study of 59 subjects with type 1 diabetes receiving either ASP or insulin glulisine (GLU) via insulin pump for 16 weeks the median (minimum-maximum) catheter occlusion rate was low for both GLU and ASP (0 [0-0.7] vs 0 [0-1.1] occlusions/month).”
  • Based on a slight difference in the maximum (but not the minimum or median) occlusion rates of subjects in the two groups, there was a slight trend toward fewer IIS occlusions with GLU.

    “based on a slight difference in the maximum (but not the minimum or median) occlusion rates of subjects in the two groups, there was a slight trend toward fewer IIS occlusions with GLU.”
  • In that study, the median occlusion rate was 0% for both groups.

    “The median occlusion rate was 0% for both groups”
  • Unexplained hyperglycemia occurred more frequently in the ASP-treated cohort.

    “Unexplained hyperglycemia occurred more frequently in the ASP-treated cohort.8”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Bode, B. W.
Affiliations
Atlanta Diabetes Associates (US)
Corresponding author
Bode, Bruce W.
Venue
Endocrine Practice
Publisher
Elsevier BV
Published
2011-03
Volume
17
Issue
2
Pages
271-280
ISSN
1530-891X (ISSN-L)
OpenAlex
W1994704037
Cited by
56
References
2
Citations by year
2025: 2 · 2024: 6 · 2023: 3 · 2022: 6 · 2021: 2 · 2020: 4 · 2019: 2 · 2018: 2 · 2017: 7 · 2016: 2 · 2015: 8 · 2014: 3 · 2013: 3 · 2012: 5
FWCI
0.41
Type
journal article
Language
en
Open access
closed
Locations
  • Endocrine Practice (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Eli Lilly and Company
  • Novo Nordisk
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
Keywords
rapid-acting insulin analogs, insulin aspart, insulin lispro, insulin glulisine, insulin pump therapy, insulin pharmacokinetics, insulin fibrillation, hypoglycemia, glycemic control, insulin analogues
MeSH terms
Drug Stability, Humans, Insulin, Insulin Aspart, Insulin Lispro

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review