CoChat

Comparison of the immunogenicity of the human papillomavirus (HPV)-16/18 vaccine and the HPV-6/11/16/18 vaccine for oncogenic non-vaccine types HPV-31 and HPV-45 in healthy women aged 18–45 years

Open access
Einstein, Mark H., Baron, Mira, Levin, Myron J, Chatterjee, Archana, Fox, Bradley, Scholar, Sofia, Rosen, Jeffrey, Chakhtoura, Nahida, Lebacq, Marie, van der Most, Robbert, Moris, Philippe, Giannini, Sandra L., Schuind, Anne, Datta, Sanjoy Kumar, Descamps, Dominique · 2011 · Human Vaccines
Cited by 114

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Protection against oncogenic non-vaccine types (cross-protection) offered by human papillomavirus (HPV) vaccines may provide a significant medical benefit. Available clinical efficacy data suggest the two licensed vaccines (HPV-16/18 vaccine, GlaxoSmithKline Biologicals (GSK), and HPV-6/11/16/18 vaccine, Merck & Co., Inc.) differ in terms of protection against oncogenic non-vaccine HPV types -31/45. The immune responses induced by the two vaccines against these two non-vaccine HPV types (cross-reactivity) was compared in an observer-blind study up to Month 24 (18 mo post-vaccination), in women HPV DNA-negative and seronegative prior to vaccination for the HPV type analyzed (HPV-010 [NCT00423046]). Geometric mean antibody titers (GMTs) measured by pseudovirion-based neutralization assay (PBNA) and enzyme-linked immunosorbent assay (ELISA) were similar between vaccines for HPV-31/45. Seropositivity rates for HPV-31 were also similar between vaccines; however, there was a trend for higher seropositivity with the HPV-16/18 vaccine (13.0-16.7%) versus the HPV-6/11/16/18 vaccine (0.0-5.0%) for HPV-45 with PBNA, but not ELISA. HPV-31/45 cross-reactive memory B-cell responses were comparable between vaccines. Circulating antigen-specific CD4+ T-cell frequencies were higher for the HPV-16/18 vaccine than the HPV-6/11/16/18 vaccine (HPV-31 [geometric mean ratio [GMR] =2.0; p=0.0002] and HPV-45 [GMR=2.6; p=0.0092]), as were the proportion of T-cell responders (HPV-31, p=0.0009; HPV-45, p=0.0793). In conclusion, immune response to oncogenic non-vaccine HPV types -31/45 was generally similar for both vaccines with the exception of T-cell response which was higher with the HPV-16/18 vaccine. Considering the differences in cross-protective efficacy between the two vaccines, the results might provide insights into the underlying mechanism(s) of protection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4161/hv.7.12.18282

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 114

Metadata

Authors
Einstein, M. H., Baron, M., Levin, M. J., Chatterjee, A., Fox, B., Scholar, S., Rosen, J., Chakhtoura, N., Lebacq, M., van der Most, R., Moris, P., Giannini, S. L., Schuind, A., Datta, S. K., & Descamps, D.
Venue
Human Vaccines
Published
2011-12
Volume
7
Issue
12
Pages
1359-1373
ISSN
  • 1554-8600 (ISSN-L)
  • 1554-8619
OpenAlex
W1979230907
Cited by
114
References
3
FWCI
11.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.