Nasal Continuous Positive Airway Pressure (CPAP) for the Respiratory Care of the Newborn Infant
The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Nasal continuous positive airway pressure (CPAP) is a noninvasive form of respiratory assistance that has been used to support spontaneously breathing infants with lung disease for nearly 40 years. Following reports that mechanical ventilation contributes to pulmonary growth arrest and the development of chronic lung disease, there is a renewed interest in using CPAP as the prevailing method for supporting newborn infants. Animal and human research has shown that CPAP is less injurious to the lungs than is mechanical ventilation. The major concepts that embrace lung protection during CPAP are the application of spontaneous breathing at a constant distending pressure and avoidance of intubation and positive-pressure inflations. A major topic for current research focuses on whether premature infants should be supported initially with CPAP following delivery, or after the infant has been extubated following prophylactic surfactant administration. Clinical trials have shown that CPAP reduces the need for intubation/mechanical ventilation and surfactant administration, but it is still unclear whether CPAP reduces chronic lung disease and mortality, compared to modern lung-protective ventilation techniques. Despite the successes, little is known about how best to manage patients using CPAP. It is also unclear whether different strategies or devices used to maintain CPAP play a role in improving outcomes in infants. Nasal CPAP technology has evolved over the last 10 years, and bench and clinical research has evaluated differences in physiologic effects related to these new devices. Ultimately, clinicians' abilities to perceive changes in the pathophysiologic conditions of infants receiving CPAP and the quality of airway care provided are likely to be the most influential factors in determining patient outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The New BPD: An Arrest of Lung Development
Jobe, A. J. (1999) · Pediatric Research · doi:10.1203/00006450-199912000-00007 · Cited by 1,013
Cited by
Kawaza, K., Machen, H. E., Brown, J., Mwanza, Z., Iniguez, S., Gest, A., Smith, E. O., Oden, M., Richards-Kortum, R. R., & Molyneux, E. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086327 · Cited by 149
“used in developed countries for decades [8].”
BackgroundMethodInfluentialEfficacy and safety of CPAP in low-and middle-income countries
Thukral, A., Sankar, M. J., Chandrasekaran, A., Agarwal, R., & Paul, V. K. (2016) · Journal of Perinatology · doi:10.1038/jp.2016.29 · Cited by 114
Implementation of Bubble CPAP in a Rural Ugandan Neonatal ICU
McAdams, R. M., Hedstrom, A. B., DiBlasi, R. M., Mant, J. E., Nyonyintono, J., Otai, C. D., Lester, D. A., & Batra, M. (2015) · Respiratory Care · doi:10.4187/respcare.03438 · Cited by 74
“SpO2, % 86 11 (20) 95 9 (20) 96 5 (18) 86 26 (13)”
Self-citationEkhaguere, O. A., Mairami, A. B., & Kirpalani, H. (2019) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2018.04.004 · Cited by 42
Metadata
- Authors
- DiBlasi, R. M.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2009-09-01
- Volume
- 54
- Issue
- 9
- Pages
- 1209-1235
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2136368222
- Cited by
- 165
- References
- 1
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nasal Continuous Positive Airway Pressure (CPAP) for the Respiratory Care of the Newborn Infant. https://app.cochat.ai/papers/10.4187/respcare.09541209
- The paper
- DiBlasi, R. M. (2009). Nasal Continuous Positive Airway Pressure (CPAP) for the Respiratory Care of the Newborn Infant. Respiratory Care. https://doi.org/10.4187/respcare.09541209
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.