Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Heart Disease Detection by Using Machine Learning Algorithms and a Real-Time Cardiovascular Health Monitoring System

Open access
Nashif, Shadman, Raihan, Md. Rakib, Islam, Md. Rasedul, Imam, Mohammad Hasan · 2018 · World Journal of Engineering and Technology

Abstract

Cardiovascular diseases are the most common cause of death worldwide over the last few decades in the developed as well as underdeveloped and developing countries. Early detection of cardiac diseases and continuous supervision of clinicians can reduce the mortality rate. However, accurate detection of heart diseases in all cases and consultation of a patient for 24 hours by a doctor is not available since it requires more sapience, time and expertise. In this study, a tentative design of a cloud-based heart disease prediction system had been proposed to detect impending heart disease using Machine learning techniques. For the accurate detection of the heart disease, an efficient machine learning technique should be used which had been derived from a distinctive analysis among several machine learning algorithms in a Java Based Open Access Data Mining Platform, WEKA. The proposed algorithm was validated using two widely used open-access database, where 10-fold cross-validation is applied in order to analyze the performance of heart disease detection. An accuracy level of 97.53% accuracy was found from the SVM algorithm along with sensitivity and specificity of 97.50% and 94.94%respectively. Moreover, to monitor the heart disease patient round-the-clock by his/her caretaker/doctor, a real-time patient monitoring system was developed and presented using Arduino, capable of sensing some real-time parameters such as body temperature, blood pressure, humidity, heartbeat. The developed system can transmit the recorded data to a central server which are updated every 10 seconds. As a result, the doctors can visualize the patient’s real-time sensor data by using the application and start live video streaming if instant medication is required. Another important feature of the proposed system was that as soon as any real-time parameter of the patient exceeds the threshold, the prescribed doctor is notified at once through GSM technology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4236/wjet.2018.64057

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 241

Metadata

Authors
Nashif, S., Raihan, M. R., Islam, M. R., & Imam, M. H.
Venue
World Journal of Engineering and Technology
Published
2018
Volume
06
Issue
04
Pages
854-873
ISSN
  • 2331-4222 (ISSN-L)
  • 2331-4249
OpenAlex
W2900623063
Cited by
241
References
1
FWCI
10.66
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart Disease Detection by Using Machine Learning Algorithms and a Real-Time Cardiovascular Health Monitoring System. https://app.cochat.ai/papers/10.4236/wjet.2018.64057
The paper
Nashif, S., Raihan, M. R., Islam, M. R., & Imam, M. H. (2018). Heart Disease Detection by Using Machine Learning Algorithms and a Real-Time Cardiovascular Health Monitoring System. World Journal of Engineering and Technology. https://doi.org/10.4236/wjet.2018.64057

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.