Cited by 97Atrial Fibrillation Management and OutcomesCoronary Interventions and DiagnosticsCardiovascular and Diving-Related Complications

Percutaneous left atrial appendage occlusion in patients with non-valvular atrial fibrillation: implantation and up to four years follow-up of the AMPLATZER Cardiac Plug

Open access
Santoro, Gennaro, Meucci, Francesco, Stolcova, Miroslava, Rezzaghi, Marco, Mori, Fabio, Palmieri, Cataldo, Paradossi, Umberto, Pastormerlo, Luigi Emilio +2 more·2016·EuroIntervention

Abstract

AIMS: Invasive imaging modalities have shown restoration of vasomotion, prevention of restenosis and, most importantly, increase in lumen area between six months and two years after first-generation everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) implantation. Our aim was to assess whether these positive findings were sustained in the long term. METHODS AND RESULTS: Patients included in the ABSORB cohort A from the Thoraxcenter Rotterdam cohort underwent coronary catheterisation including angiography, intravascular ultrasound (IVUS), virtual histology, optical coherence tomography (OCT) and vasomotion testing at five years. Eight out of 16 patients underwent catheterisation and scaffold assessment with multiple imaging modalities. A trend towards an increase in minimum luminal diameter was observed between two and five years by angiography (1.95±0.37 mm vs. 2.14±0.38 mm; p=0.09). IVUS data showed an increase in mean lumen area at five years (6.96±1.13 mm2) compared to six months (6.17±0.74 mm2; p=0.06) and two years (6.56±1.16 mm2; p=0.12), primarily due to a persistent reduction in plaque area size between six months and five years (9.17±1.86 mm2 vs. 7.57±1.63 mm2; p=0.03). The necrotic core area was reduced at five years compared to post-procedural results. In OCT, an increase in mean and minimal luminal area was observed. Moreover, no scaffold struts could be identified and a smooth endoluminal lining was observed. The scaffolded coronary segment did not show signs of endothelial dysfunction with acetylcholine testing. CONCLUSIONS: At five years, the Absorb BVS is no longer discernible by any invasive imaging method and endothelial function is restored. Late luminal enlargement persists up to five years of follow-up without adaptive vessel remodelling.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4244/eijy14m10_12

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es GA, Steg PG, Morel MA, Mauri L, Vranckx P, McFadden E, Lansky A, Hamon M, Krucoff MW, Serruys PW; Academic Research Consortium. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation. 2007;115:2344-51.
  2. Tearney GJ, Regar E, Akasaka T, Adriaenssens T, Barlis P, Bezerra HG, Bouma B, Bruining N, Cho JM, Chowdhary S, Costa MA, de Silva R, Dijkstra J, Di Mario C, Dudek D, Falk E, Feldman MD, Fitzgerald P, Garcia-Garcia HM, Gonzalo N, Granada JF, Guagliumi G, Holm NR, Honda Y, Ikeno F, Kawasaki M, Kochman J, Koltowski L, Kubo T, Kume T, Kyono H, Lam CC, Lamouche G, Lee DP, Leon MB, Maehara A, Manfrini O, Mintz GS, Mizuno K, Morel MA, Nadkarni S, Okura H, Otake H, Pietrasik A, Prati F, Räber L, Radu MD, Rieber J, Riga M, Rollins A, Rosenberg M, Sirbu V, Serruys PW, Shimada K, Shinke T, Shite J, Siegel E, Sonoda S, Suter M, Takarada S, Tanaka A, Terashima M, Thim T, Uemura S, Ughi GJ, van Beusekom HM, van der Steen AF, van Es GA, van Soest G, Virmani R, Waxman S, Weissman NJ, Weisz G; International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT). Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation. J Am Coll Cardiol. 2012;59:1058- 72. Erratum in J Am Coll Cardiol. 2012;59:1662.
  3. Karanasos A, Ligthart JM, Regar E. In-stent neoatheroscle- rosis: a cause of late stent thrombosis in a patient with "full metal jacket" 15 years after implantation: insights from optical coherence tomography. JACC Cardiovasc Interv. 2012;5:799-800.

Cited by

Sorted by citations

Authors
Santoro, G., Meucci, F., Stolcova, M., Rezzaghi, M., Mori, F., Palmieri, C., Paradossi, U., Pastormerlo, L. E., Rosso, G., & Berti, S.
Affiliations
Erasmus MC (NL)
Venue
EuroIntervention
Published
2016-02
Volume
11
Issue
10
Pages
1188-1194
ISSN
1774-024X (ISSN-L)
OpenAlex
W2417657882
Cited by
97
References
31
Citations by year
2026: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 6 · 2020: 13 · 2019: 9 · 2018: 15 · 2017: 16 · 2016: 21 · 2015: 10 · 2014: 1
FWCI
16.77
Type
journal article
Language
en
Open access
Locations
  • EuroIntervention (publishedVersion)
  • PubMed (publishedVersion)
  • EUR Research Repository (Erasmus University Rotterdam) (publishedVersion, other-oa)
  • EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
Funders
  • Erasmus Medisch Centrum
  • Abbott Vascular
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Surgery › Coronary Interventions and Diagnostics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Cardiovascular and Diving-Related Complications
Keywords
Amplatzer Cardiac Plug, left atrial appendage closure, non-valvular atrial fibrillation, percutaneous left atrial appendage closure, bioresorbable vascular scaffolds, everolimus-eluting scaffold, Absorb BVS, long-term follow-up, intravascular ultrasound, optical coherence tomography, virtual histology, restenosis, endothelial function, necrotic core, plaque area
MeSH terms
Everolimus, Aged, Cardiovascular Agents, Coronary Artery Disease, Coronary Vessels, Female, Humans, Male, Middle Aged, Necrosis, Netherlands, Predictive Value of Tests, Time Factors, Treatment Outcome, Coronary Angiography, Ultrasonography, Interventional, Coated Materials, Biocompatible, Absorbable Implants, Tomography, Optical Coherence, Plaque, Atherosclerotic, Percutaneous Coronary Intervention, Multimodal Imaging, Vascular Remodeling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review