EVALUATION OF THE BINAX NOW® ICT TEST VERSUS POLYMERASE CHAIN REACTION AND MICROSCOPY FOR THE DETECTION OF MALARIA IN RETURNED TRAVELERS
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Microscopic detection of Plasmodium species has been the reference standard for the diagnosis of malaria for more than a century. However, maintaining a sufficient level of expertise in microscopic diagnosis can be challenging, particularly in non-endemic countries. The objective of this study was to compare a new rapid malaria diagnostic device (NOW® ICT Malaria Test; Binax, Inc., Portland, ME) to polymerase chain reaction (PCR) and expert microscopy for the diagnosis of malaria in 256 febrile returned travelers. Compared with PCR, the NOW® ICT test showed a sensitivity of 94% for the detection of P. falciparum malaria (96% for pure P. falciparum infection) and 84% for non-P. falciparum infections (87% for pure P. vivax infections and 62% for pure P. ovale and P. malariae infections), with an overall specificity of 99%. The Binax NOW® ICT may represent a useful adjunct for the diagnosis of P. falciparum and P. vivax malaria in febrile returned travelers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snounou, G., Viriyakosol, S., Zhu, X. P., Jarra, W., Pinheiro, L., do Rosario, V. E., Thaithong, S., & Brown, K. N. (1993) · Molecular and Biochemical Parasitology · doi:10.1016/0166-6851(93)90077-b · Cited by 1,591
Imported Malaria: Prospective Analysis of Problems in Diagnosis and Management
Kain, K. C., Harrington, M. A., Tennyson, S., & Keystone, J. S. (1998) · Clinical Infectious Diseases · doi:10.1086/514616 · Cited by 371
Self-citationAccuracy of routine laboratory diagnosis of malaria in the United Kingdom.
Milne, L. M., Kyi, M. S., Chiodini, P. L., & Warhurst, D. C. (1994) · Journal of Clinical Pathology · doi:10.1136/jcp.47.8.740 · Cited by 228
Brown, A. E., Kain, K. C., Pipithkul, J., & Webster, H. K. (1992) · Transactions of the Royal Society of Tropical Medicine and Hygiene · doi:10.1016/0035-9203(92)90147-5 · Cited by 136
Self-citation
Cited by
A Review of Malaria Diagnostic Tools: Microscopy and Rapid Diagnostic Test (RDT)
Wongsrichanalai, C., Barcus, M. J., Muth, S., Sutamihardja, A., & Wernsdorfer, W. H. (2007) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2007.77.119 · Cited by 939
Update on Rapid Diagnostic Testing for Malaria
Murray, C. K., Gasser, R. A., Magill, A. J., & Miller, R. S. (2008) · Clinical Microbiology Reviews · doi:10.1128/cmr.00035-07 · Cited by 505
Rougemont, M., Van Saanen, M., Sahli, R., Hinrikson, H. P., Bille, J., & Jaton, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.12.5636-5643.2004 · Cited by 469
WHO Guidelines for the treatment of malaria
Kunte, R., & Kunwar, R. (2011) · Medical Journal Armed Forces India · doi:10.1016/s0377-1237(16)30022-3 · Cited by 341
Rapid diagnostic tests for diagnosing uncomplicated P. falciparum malaria in endemic countries
Abba, K., Deeks, J. J., Olliaro, P. L., Naing, C.-M., Jackson, S. M., Takwoingi, Y., Donegan, S., & Garner, P. (2011) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008122.pub2 · Cited by 230
Assessment of the prozone effect in malaria rapid diagnostic tests
Gillet, P., Mori, M., Van Esbroeck, M., Ende, J. V. D., & Jacobs, J. (2009) · Malaria Journal · doi:10.1186/1475-2875-8-271 · Cited by 168
“False-negative results at low parasite densities can be countered by diagnostic algorithms prescribing repeat or serial testing when malaria is suspected and the initial RDT test result is negative [6,12].”
BackgroundMeta-Analysis: Accuracy of Rapid Tests for Malaria in Travelers Returning from Endemic Areas
Marx, A., Pewsner, D., Egger, M., Nüesch, R., Bucher, H. C., Genton, B., Hatz, C., & Jüni, P. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-142-10-200505170-00009 · Cited by 164
“Four studies were from North America (21, 25, 36, 37), 1 study was from Australia (19), and the other studies were from Europe.”
BackgroundResultInfluentialKhairnar, K., Martin, D., Lau, R., Ralevski, F., & Pillai, D. R. (2009) · Malaria Journal · doi:10.1186/1475-2875-8-284 · Cited by 101
“Although microscopy can be sensitive to a threshold of 550 parasites/μl depending on the expertise of the microscopist, the average microscopist is likely to achieve a sensitivity closer to 100 parasites/μl or higher [22,23].”
BackgroundMaltha, J., Gillet, P., Bottieau, E., Cnops, L., van Esbroeck, M., & Jacobs, J. (2010) · Malaria Journal · doi:10.1186/1475-2875-9-171 · Cited by 87
Nkrumah, B., Acquah, S. E., Ibrahim, L., May, J., Brattig, N., Tannich, E., Nguah, S. B., Adu-Sarkodie, Y., & Huenger, F. (2011) · BMC Infectious Diseases · doi:10.1186/1471-2334-11-143 · Cited by 45
“falciparum infections and has a higher false positive rate due to the persistence of the antigen target HRP 2 [8,9,26].”
Background
Metadata
- Authors
- FARCAS, G. A., ZHONG, K. J. Y., LOVEGROVE, F. E., GRAHAM, C. M., & KAIN, K. C.
- Venue
- The American Journal of Tropical Medicine and Hygiene
- Published
- 2003-12
- Volume
- 69
- Issue
- 6
- Pages
- 589-592
- ISSN
- 0002-9637 (ISSN-L)
- OpenAlex
- W2154398081
- Cited by
- 127
- References
- 4
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.