Recent Advances in Brain Injury Research: A New Human Head Model Development and Validation
Abstract
Many finite element models have been developed by several research groups in order to achieve a better understanding of brain injury. Due to the lack of experimental data, validation of these models has generally been limited. Consequently, applying these models to investigate brain responses has also been limited. Over the last several years, several versions of the Wayne State University brain injury model (WSUBIM) were developed. However, none of these models is capable of simulating indirect impacts with an angular acceleration higher than 8,000 rad/s(2). Additionally, the density and quality of the mesh in the regions of interest are not detailed and sensitive enough to accurately predict the stress/strain level associated with a wide range of impact severities. In this study, WSUBIM version 2001, capable of simulating direct and indirect impacts with a combined translational and rotational acceleration of the head up to 200 g and 12,000 rad/s(2) has been developed. This new finely meshed model, consisting of more than 314,500 elements and 281,800 nodes, also simulates an anatomically detailed facial bone model. An additional new feature of the model is the damageable material property representation of the facial bone and the skull, allowing it to simulate bony fractures. The model was subjected to extensive validation using published cadaveric test data. These data include the intracranial and ventricular pressure data reported by Nahum et al. (1977) and Trosseille et al. (1992), the relative displacement data between the brain and the skull reported by King et al. (1999) and Hardy et al. (2001), and the facial impact data reported by Nyquist et al. (1986) and Allsop et al. (1988). With the enhanced accuracy of model predictions offered by this new model, along with new experimental data, it is hoped that it will become a powerful tool to further our understanding of the mechanisms of injury and the tolerance of the brain to blunt impact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Holbourn, A. H. S. (1943) · The Lancet · doi:10.1016/s0140-6736(00)87453-x · Cited by 918
Misch, C. E., Qu, Z., & Bidez, M. W. (1999) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(99)90437-8 · Cited by 509
Hardy, W. N., Foster, C. D., Mason, M. J., Yang, K. H., King, A. I., & Tashman, S. (2001) · SAE Technical Paper Series · doi:10.4271/2001-22-0016 · Cited by 476
Self-citationBiomechanics of Acute Subdural Hematoma
GENNARELLI, T. A., & THIBAULT, L. E. (1982) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-198208000-00005 · Cited by 475
Comparison of Brain Responses Between Frontal and Lateral Impacts by Finite Element Modeling
Zhang, L., Yang, K. H., & King, A. I. (2001) · Journal of Neurotrauma · doi:10.1089/089771501750055749 · Cited by 322
Self-citationA Proposed New Biomechanical Head Injury Assessment Function - the Maximum Power Index
Newman, J. A., & Shewchenko, N. (2000) · SAE Technical Paper Series · doi:10.4271/2000-01-sc16 · Cited by 307
Dynamic mechanical properties of human brain tissue
Fallenstein, G. T., Hulce, V. D., & Melvin, J. W. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90079-7 · Cited by 288
Mechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study
Lotz, J. C., Gerhart, T. N., & Hayes, W. C. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199001000-00020 · Cited by 284
Pudenz, R. H., & Shelden, C. H. (1946) · Journal of Neurosurgery · doi:10.3171/jns.1946.3.6.0487 · Cited by 255
Three-Dimensional Human Head Finite-Element Model Validation Against Two Experimental Impacts
Willinger, R., Kang, H.-S., & Diaw, B. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.165 · Cited by 222
A New Model Comparing Impact Responses of the Homogeneous and Inhomogeneous Human Brain
Zhou, C., Khalil, T. B., & King, A. I. (1995) · SAE Technical Paper Series · doi:10.4271/952714 · Cited by 201
Self-citationHuman vertebral body apparent and hard tissue stiffness
Hou, F. J., Lang, S. M., Hoshaw, S. J., Reimann, D. A., & Fyhrie, D. P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00110-9 · Cited by 197
Head Injury in Man and Experimental Animals: Neuropathology
Adams, J. H., Graham, D. I., & Gennarelli, T. A. (1983) · Acta Neurochirurgica Supplementum · doi:10.1007/978-3-7091-4147-2_2 · Cited by 190
Axonal degeneration induced by experimental noninvasive minor head injury
Jane, J. A., Steward, O., & Gennarelli, T. (1985) · Journal of Neurosurgery · doi:10.3171/jns.1985.62.1.0096 · Cited by 158
Bandak, F. A., & Eppinger, R. H. (1994) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/942215 · Cited by 157
Facial Impact Response — A Comparison of the Hybrid III Dummy and Human Cadaver
Allsop, D. “., Warner, C. Y., Wille, M. G., Schneider, D. C., & Nahum, A. M. (1988) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/881719 · Cited by 134
Ross, D. T., Meaney, D., Sabol, M., Smith, D. H., & Gennarelli, T. (1994) · Experimental Neurology · doi:10.1006/exnr.1994.1067 · Cited by 130
Al-Bsharat, A. S., Hardy, W. N., Yang, K. H., Khalil, T. B., Tashman, S., & King, A. I. (1999) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/99sc22 · Cited by 116
Self-citationPilz, P. (1983) · Acta Neurochirurgica Supplementum · doi:10.1007/978-3-7091-4147-2_17 · Cited by 111
Zhang, L., Yang, K. H., & King, A. I. (2001) · Neurological Research · doi:10.1179/016164101101198488 · Cited by 97
Self-citationAbel, J. M., Gennarelli, T. A., & Segawa, H. (1978) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/780886 · Cited by 91
Ommaya, A. K., Hirsch, A. E., Yarnell, P. R., & Harris, E. H. (1967) · doi:10.21236/ad0666837 · Cited by 91
Axisymmetric finite element analysis of the lateral tibial plateau
Hayes, W. C., Swenson, L. W., & Schurman, D. J. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90040-4 · Cited by 86
Simulation of acute subdural hematoma and diffuse axonal injury in coronal head impact
Bradshaw, D. R. S., Ivarsson, J., Morfey, C. L., & Viano, D. C. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00135-4 · Cited by 85
Computational Analysis of Head Impact Response Under Car Crash Loadings
Dimasi, F., Eppinger, R. H., & Bandak, F. A. (1995) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/952718 · Cited by 84
Dynamic Characteristics of the Tissues of the Head
McElhaney, J. H., Melvin, J. W., Roberts, V. L., & Portnoy, H. D. (1973) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-01604-4_34 · Cited by 84
Regional Differences in Mechanical Properties of the Porcine Central Nervous System
Arbogast, K. B., & Margulies, S. S. (1997) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/973336 · Cited by 78
Rosenblum, W. I., Greenberg, R. P., Seelig, J. M., & Becker, D. P. (1981) · Neurosurgery · doi:10.1227/00006123-198112000-00001 · Cited by 74
Some New Data Related to Human Tolerance Obtained from Volunteer Boxers
Pincemaille, Y., Trosseille, X., Mack, P., Tarrière, C., Breton, F., & Renault, B. (1989) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/892435 · Cited by 74
Relation Between Diffuse Axonal Injury and Internal Head Structures on Blunt Impact
Nishimoto, T., & Murakami, S. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834294 · Cited by 63
A Strain Energy Approach to the Mechanics of Skull Fracture
Melvin, J. W., & Evans, F. G. (1971) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/710871 · Cited by 51
Cited by
Mechanical characterization of brain tissue in compression at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.01.022 · Cited by 426
Meaney, D. F., & Smith, D. H. (2011) · Clinics in Sports Medicine · doi:10.1016/j.csm.2010.08.009 · Cited by 425
Magnetic resonance elastography of the brain
Kruse, S. A., Rose, G. H., Glaser, K. J., Manduca, A., Felmlee, J. P., Jack, C. R., & Ehman, R. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.030 · Cited by 424
A Study of the Response of the Human Cadaver Head to Impact
Hardy, W. N., Mason, M. J., Foster, C. D., Shah, C. S., Kopacz, J. M., Yang, K. H., King, A. I., Bishop, J., Bey, M., Anderst, W., et al. (2007) · SAE Technical Paper Series · doi:10.4271/2007-22-0002 · Cited by 371
Self-citationMao, H., Zhang, L., Jiang, B., Genthikatti, V. V., Jin, X., Zhu, F., Makwana, R., Gill, A., Jandir, G., Singh, A., et al. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025101 · Cited by 369
Self-citation
Metadata
- Authors
- Zhang, L., Yang, K. H., Dwarampudi, R., Omori, K., Li, T., Chang, K., Hardy, W. N., Khalil, T. B., & King, A. I.
- Venue
- SAE Technical Paper Series
- Publisher
- SAE International
- Published
- 2001-11-01
- Volume
- 1
- Pages
- 369-94
- ISSN
- 0148-7191 (ISSN-L)
- OpenAlex
- W1928451406
- Cited by
- 374
- References
- 32
- FWCI
- 49.78
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.