Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 350

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

On the Development of the SIMon Finite Element Head Model

Takhounts, Erik G., Eppinger, Rolf H., Campbell, J. Quinn, Tannous, Rabih E., Power, Erik D., Shook, Lauren S. · 2003 · SAE Technical Paper Series

Abstract

The SIMon (Simulated Injury Monitor) software package is being developed to advance the interpretation of injury mechanisms based on kinematic and kinetic data measured in the advanced anthropomorphic test dummy (AATD) and applying the measured dummy response to the human mathematical models imbedded in SIMon. The human finite element head model (FEHM) within the SIMon environment is presented in this paper. Three-dimensional head kinematic data in the form of either a nine accelerometer array or three linear CG head accelerations combined with three angular velocities serves as an input to the model. Three injury metrics are calculated: Cumulative strain damage measure (CSDM) - a correlate for diffuse axonal injury (DAI); Dilatational damage measure (DDM) - to estimate the potential for contusions; and Relative motion damage measure (RMDM) - a correlate for acute subdural hematoma (ASDH). During the development, the SIMon FEHM was tuned using cadaveric neutral density targets (NDT) data and further validated against the other available cadaveric NDT data and animal brain injury experiments. The hourglass control methods, integration schemes, mesh density, and contact stiffness penalty coefficient were parametrically altered to investigate their effect on the model's response. A set of numerical and physical parameters was established that allowed a satisfactory prediction of the motion of the brain with respect to the skull, when compared with the NDT data, and a proper separation of injury/no injury cases, when compared with the brain injury data. Critical limits for each brain injury metric were also established. Finally, the SIMon FEHM performance was compared against HIC15 through the use of NHTSA frontal and side impact crash test data. It was found that the injury metrics in the current SIMon model predicted injury in all cases where HIC15 was greater than 700 and several cases from the side impact test data where HIC15 was relatively small. Side impact was found to be potentially more injurious to the human brain than frontal impact due to the more severe rotational kinematics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4271/2003-22-0007

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 350

Metadata

Authors
Takhounts, E. G., Eppinger, R. H., Campbell, J. Q., Tannous, R. E., Power, E. D., & Shook, L. S.
Venue
SAE Technical Paper Series
Published
2003-10-27
Volume
1
Pages
107-33
ISSN
0148-7191 (ISSN-L)
OpenAlex
W175120886
Cited by
350
References
24
FWCI
32.33
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On the Development of the SIMon Finite Element Head Model. https://app.cochat.ai/papers/10.4271/2003-22-0007
The paper
Takhounts, E. G., Eppinger, R. H., Campbell, J. Q., Tannous, R. E., Power, E. D., & Shook, L. S. (2003). On the Development of the SIMon Finite Element Head Model. SAE Technical Paper Series. https://doi.org/10.4271/2003-22-0007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.