Combined Fluid Loop Thermal Management for Electric Drive Vehicle Range Improvement
Open accessThe DOI matches its Crossref record.
Abstract
Electric drive vehicles (EDVs) have complex thermal management requirements not present in conventional vehicles. In addition to cabin conditioning, the energy storage system (ESS) and power electronics and electric motor (PEEM) subsystems also require thermal management. Many current-generation EDVs utilize separate cooling systems, adding both weight and volume, and lack abundant waste heat from an engine for cabin heating. Some use battery energy to heat the cabin via electrical resistance heating, which can result in vehicle range reductions of 50% under cold ambient conditions. These thermal challenges present an opportunity for integrated vehicle thermal management technologies that reduce weight and volume and increase cabin heating efficiency.Bench testing was conducted to evaluate a combined fluid loop technology that unifies the cabin air-conditioning and heating, ESS thermal management, and PEEM cooling into a single liquid coolant-based system. This system has separate hot and cold fluid streams that are directed to the thermal components as required. The advantages include PEEM waste heat recovery to supplement cabin heating and heat pump operation without refrigerant cycle reversal. A bench test apparatus was constructed to apply transient drive cycle loads to the thermal system and measure the performance under ambient temperatures from −12°C to 43°C. The system proved capable of meeting component thermal requirements at all tested conditions. Furthermore, the system demonstrated a 9% range increase on a nationally weighted basis that accounts for vehicle usage and ambient temperature. The range improvement is expected to be greater for an optimized in-vehicle system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A critical review of battery thermal performance and liquid based battery thermal management
Wu, W., Wang, S., Wu, W., Chen, K., Hong, S., & Lai, Y. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.12.051 · Cited by 1,214
The solutions to electric vehicle air conditioning systems: A review
Zhang, Z., Wang, J., Feng, X., Chang, L., Chen, Y., & Wang, X. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.04.005 · Cited by 283
A review on the liquid cooling thermal management system of lithium-ion batteries
Wu, C., Sun, Y., Tang, H., Zhang, S., Yuan, W., Zhu, L., & Tang, Y. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.124173 · Cited by 277
Thermal characterisation of compact heat exchangers for air heating and cooling in electric vehicles
Torregrosa-Jaime, B., Corberán, J. M., Payá, J., & Delamarche, J. L. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.01.017 · Cited by 25
Demand-Based Control Design for Efficient Heat Pump Operation of Electric Vehicles
Dvorak, D., Basciotti, D., & Gellai, I. (2020) · Energies · doi:10.3390/en13205440 · Cited by 23
“Leighton [24] suggested combining the cooling circuit for the battery with the water cycle for the cabin heating.”
Background
Metadata
- Authors
- Leighton, D.
- Venue
- SAE International Journal of Passenger Cars - Mechanical Systems
- Publisher
- SAE International
- Published
- 2015-04-14
- Volume
- 08
- Issue
- 2
- Pages
- 711-720
- ISSN
- 1946-3995 (ISSN-L)
- 1946-4002
- OpenAlex
- W2052499880
- Cited by
- 89
- References
- 0
- FWCI
- 8.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined Fluid Loop Thermal Management for Electric Drive Vehicle Range Improvement. https://app.cochat.ai/papers/10.4271/2015-01-1709
- The paper
- Leighton, D. (2015). Combined Fluid Loop Thermal Management for Electric Drive Vehicle Range Improvement. SAE International Journal of Passenger Cars - Mechanical Systems. https://doi.org/10.4271/2015-01-1709
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.