Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions
Open accessThe DOI matches its DataCite record; 103 of the 110 references it cites were found in a registry or an index; none of the 94 sources its claims cite is checked for support yet.
Abstract
The transition of materials and devices to nanometer, atomic, and quantum scales makes thermal characterization increasingly challenging, driving the need for advanced nanoscale thermometry. Fluorescence nanothermometry has emerged as a powerful approach, enabling remote, spatially resolved temperature measurements with sub-micrometer-to-nanometer precision across applications in nanoelectronics, microfluidics, and biological systems. In these systems, temperature is inferred from variations in fluorescence observables, including spectral position, intensity, linewidth, and excited-state dynamics. This review provides a comprehensive and critical overview of fluorescence nanothermometry, covering fundamental mechanisms, material platforms, recent advances, and emerging applications. It further presents a critical evaluation of key challenges and discusses emerging strategies and future research directions toward achieving robust, real-time thermometry. It is anticipated that this review will stimulate further advances in material platforms and system design, accelerating the development of accurate, scalable, and application-ready nanoscale thermometers.
Overview
CoChat Summary
TL;DR
This review surveys nanoscale fluorescence (luminescence) thermometry, comparing it against IR, Raman, thermoreflectance, scanning thermal microscopy and plasmon-energy-expansion thermometry, and then focuses on diamond color centers (NV, GeV, SiV, SnV, PbV) as the most advanced probes, with QDs and upconversion nanoparticles (UCNPs) covered as complementary platforms. It closes with applications in micro/nanoelectronics, 3D thermal imaging and disease diagnosis, and argues that multiparametric readout combined with machine learning is the main route to reducing calibration burden and improving precision.
Key findings
- Diamond color centers support both spin-based (ODMR) and all-optical thermometry: the NV ground-state zero-field splitting is ~2.88 GHz at room temperature with a temperature coefficient ΔD/ΔT ≈ −77 kHz °C⁻¹, and the NV zero-phonon line sits at 1.945 eV (637 nm). Reported temperature resolutions span from 76 μK Hz⁻¹ᐟ² (pulsed ODMR, 1 mm) and 10 mK Hz⁻¹ᐟ² (CW ODMR, bulk) down to ~1.4 K Hz⁻¹ᐟ² for in vivo *C. elegans* work, with spatial resolution reaching 3.7 nm for intracellular NV thermometry.
- All-optical diamond thermometry avoids microwaves: SiV two-photon excitation achieved 6.6 mK Hz⁻¹ᐟ², multiparametric SiV analysis ~13 mK Hz⁻¹ᐟ² over sub-250 nm dimensions, and a fiber-coupled GeV probe monitored brain temperature in freely moving mice with accuracy better than 0.15 °C and 230 mK Hz⁻¹ᐟ² resolution.
- UCNP thermometry is dominated by Boltzmann ratiometric schemes (typically Er³⁺ ²H₁₁/₂–⁴S₃/₂): Sedlmeier et al. achieved better than 0.5 °C resolution over 20–45 °C; the highest reported relative sensitivity cited is 9.52% K⁻¹, while KLuWO₄:Tm³⁺/Ho³⁺ under 808 nm excitation gave 2.8% K⁻¹ and 0.2 K resolution at 300 K. Water absorption at 980 nm is ~20× that at 800 nm.
- Multiparametric/machine-learning approaches set the current performance ceiling: Maturi et al. reported a tenfold improvement over single-feature methods with 50% K⁻¹ relative sensitivity and uncertainty below 0.1 K; a combined Raman+PL ML model reached 0.7 K accuracy, 0.6 K·Hz⁻¹ᐟ² resolution and 0.04 K⁻¹ sensitivity.
Methods
- Design: narrative/critical review with a comparative framework, not a primary experimental study. It classifies thermometry by physical mechanism (primary vs secondary), contact vs non-contact, and signal nature (optical vs non-optical), then defines figures of merit (absolute sensitivity Sₐ, relative sensitivity Sᵣ, temperature resolution η_T, ΔT_min, temporal resolution Δt_min).
- Data: literature synthesis supported by two comparison tables — Table 2 (ODMR-based diamond thermometry by defect, modality, spatial resolution, temperature resolution, platform) and Table 3 (all-optical diamond thermometry by defect, optical observable, spatial and temperature resolution, platform) — plus a bibliometric analysis of Web of Science Core Collection records (1900–2025) using a luminescence/thermometry/diamond search query run on 19 March 2026.
- Main analysis: qualitative comparison of probe platforms (diamond color centers, QDs, UCNPs) and application domains (micro/nanoelectronics, 3D thermal imaging, disease diagnosis), with market figures cited from third-party reports (temperature sensor market USD 9.93 billion in 2026 → USD 13.41 billion by 2031, 6.2% CAGR; optical temperature sensors to USD 3.5 billion by 2033, 7.8% CAGR).
Limitations
- Stated by the paper: batch-to-batch variation in nanomaterial quality forces individual sensor calibration, which is impractical at scale; spatial resolution is diffraction-limited (~λ/2NA, roughly 200 nm for visible light and NA ≈ 1.4); self-absorption and scattering perturb PL intensity and spectral position; laser-induced self-heating is exacerbated by impurities, surface carbon and low-thermal-conductivity substrates; NV thermometry requires microwaves that are absorbed in biological media; nanodiamonds are sensitive to surface ligands, surfactants and trap states; and excitation-power mismatch between calibration and measurement biases ratiometric readouts, especially when the two bands arise from different-order processes (I₁ ∝ P vs I₂ ∝ P²). Thermal quenching of emission is also flagged as a general constraint.
- Evident from the text: the review reports no new measurements or error analysis of its own, and its quantitative claims are inherited from the cited primary studies, so the tables' figures of merit are not independently verified. The supplied text is also visibly corrupted in places (truncated abstract, broken sentences, mangled table formatting and reference numbering), which limits confidence in some extracted numbers.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures





![Figure 4 All optical diamond thermometry (a) Atomic structure of group IV color centers exhibiting D3d symmetry in a split-vacancy configuration, where the group IV impurity atom (M, orange) is positioned between two adjacent carbon vacancies (V, white). [Reproduced from [108] under the terms of the CC-BY 4.0 license. Copyright 2019, Springer Nature], (b) Representative photoluminescence (PL) spectra of SiV⁻, GeV⁻, SnV⁻, and PbV⁻ color centers at room temperature. [Reproduced from ref [108] under the terms of the CC-BY 4.0 license. Copyright 2019, Springer Nature], (c) Energy-level diagram of group IV color centers illustrating the principle of all-optical thermometry. (d) Photoluminescence spectra of SiVcontaining nanodiamonds acquired at low and elevated temperatures, demonstrating a temperature-induced redshift of the ZPL. [Adapted with permission [109]. Copyright 2022,](https://figures.cochat.ai/paper-figures/43601fa43c824f02b76f26957b1455cd/nanoscale-fluorescence-thermometry-probes-recent-advances-and-emerging-figure-4.png)
![Figure 5 QDs-based fluorescence thermometry (a) Representative QD core materials plotted according to their emission wavelengths, highlighting their potential biological application windows. [Reproduced with permission [140]. Copyright 2005, Springer Nature] (b) Time resolved photoluminescence decay curves of didodecyl dimethylammonium bromide (DDAB)/tetraoctylammonium bromide (TOAB) capped CsPbBr3 QD film at different temperatures. [Reproduced with permission [138]. Copyright 2024, Elsevier] (c) Schematic energy band diagram of Mn²⁺ -doped ZnS quantum dots (QDs), along with temperaturedependent photoluminescence (PL) spectra recorded during heating and cooling cycles. The variation of the PL peak position and the integrated emission intensity as a function of](https://figures.cochat.ai/paper-figures/8be5b6749fff4cc6beeb97a47e79a83c/nanoscale-fluorescence-thermometry-probes-recent-advances-and-emerging-figure-5.png)
![Figure 6 Upconversion nanoparticles (UCNPs) based fluorescence thermometry (a) Schematic illustration of the Yb/Ho/Ce:NaGdF4@Yb/Tm:NaYF4 core -shell nanostructure, along with temperature-dependent upconversion emission spectra recorded under 980 nm excitation and normalized to the green emission peak, and a histogram showing the integrated intensities of the blue, green, and red emission bands as a function of temperature. [Adapted with permission [153]. Copyright 2013, Royal Society of Chemistry (RSC)] (b) Variable-angle thermal sensing performance of the 1 mm PC@Au film@UCNPs composite, showing a schematic of the angle-](https://figures.cochat.ai/paper-figures/0db5cef4f1d746289e8f229046091f67/nanoscale-fluorescence-thermometry-probes-recent-advances-and-emerging-figure-6.png)


![Figure 9 Disease diagnosis with fluorescence thermometry. (a) Diagram summarizing medical conditions that result in localized or systemic thermal fluctuations. [Reproduced with permission [180]. Copyright 2025, John Wiley and Sons] (b) Early cancer detection using fluorescence thermometry. Time-dependent evolution of Δτ, tumor volume and the surface temperature difference between tumoral and adjacent healthy tissue following cancer cell](https://figures.cochat.ai/paper-figures/f4a0f53835aa469c86fffff9bd2e3ec2/nanoscale-fluorescence-thermometry-probes-recent-advances-and-emerging-figure-9.png)
Verification
Claims the paper makes
0 Valid · 9 Not valid · 85 Not checked · 63 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Following the pioneering contributions of Neubert and Urbach, research activity in this area remained largely dormant until the early 1980s, with fewer than ten publications per year, as illustrated in Figure2a.”
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > 9.2 Future Directions
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“Two distinct emission bands were observed in the MZQDs at approximately 400 nm and 595 nm.”
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > 6. QDs-Based Fluorescence Thermometry
What the sources say
- Not matchedcites [141]
The reference list we hold has no entry [141].
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Temperature-dependent measurements revealed enhanced sensing performance, with a relative sensitivity of 2.4% K -1 , highlighting its promise for optical thermometry applications.”
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > 6. QDs-Based Fluorescence Thermometry
What the sources say
- Not matchedcites [153]
The reference list we hold has no entry [153].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“As a relative metric, the temperature resolution can be improved by increasing the signal integration time, thereby reducing statistical noise.”
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > 3.2 Temperature Resolution
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Consequently, semiconductor quantum dots have been explored as an alternative platform for optical thermometry.”
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > 6. QDs-Based Fluorescence Thermometry
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
73 more claims
Create a free account to see all 157 claims and every source verdict.
- Probably not a substantial claim. 35
- It may state two separate claims as one. 56
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > 4. Fluorescence Thermometry
“nanoelectronics [Reproduced with permission [74].Copyright 2020, American Chemical Society]”
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > References
“74. Vogel, R.; Groefsema, D. W.; van den Bulk, M. A., et al., Acs Applied Materials & Interfaces 2025, 17 (14), 21215-21222. DOI 10.1021/acsami.5c00243.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > 6. QDs-Based Fluorescence Thermometry
“[Reproduced with permission [154].Copyright 2013, Royal Society of Chemistry (RSC)]”
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > References
“154. Huang, G.; Wu, X.; Zhan, S.; Liu, Y., Journal of Materials Chemistry C 2022, 10 (13), 5190-5199. DOI 10.1039/D1TC05838J.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > 9.2 Future Directions
“[Adapted with permission[153].Copyright 2013, Royal Society of Chemistry (RSC)]”
§ Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions > References
“153. Xu, M.; Chen, D.; Huang, P., et al., Journal of Materials Chemistry C 2016, 4 (27), 6516-6524. DOI 10.1039/C6TC02218A.”
Citations
Cites
The nitrogen-vacancy colour centre in diamond
Doherty, M. W., Manson, N. B., Delaney, P., Jelezko, F., Wrachtrup, J., & Hollenberg, L. C. L. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.02.001 · Cited by 2,866
Nanometre-scale thermometry in a living cell
Kucsko, G., Maurer, P. C., Yao, N. Y., Kubo, M., Noh, H. J., Lo, P. K., Park, H., & Lukin, M. D. (2013) · Nature · doi:10.1038/nature12373 · Cited by 1,951
Brites, C. D. S., Lima, P. P., Silva, N. J. O., Millán, A., Amaral, V. S., Palacio, F., & Carlos, L. D. (2012) · Nanoscale · doi:10.1039/c2nr30663h · Cited by 1,592
Analysis of heat flow in layered structures for time-domain thermoreflectance
Cahill, D. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1819431 · Cited by 1,543
Jaque, D., & Vetrone, F. (2012) · Nanoscale · doi:10.1039/c2nr30764b · Cited by 1,507
Lanthanide‐Based Thermometers: At the Cutting‐Edge of Luminescence Thermometry
Brites, C. D. S., Balabhadra, S., & Carlos, L. D. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801239 · Cited by 1,173
Remote thermometry with thermographic phosphors: Instrumentation and applications
Allison, S. W., & Gillies, G. T. (1997) · Review of Scientific Instruments · doi:10.1063/1.1148174 · Cited by 824
High-Precision Nanoscale Temperature Sensing Using Single Defects in Diamond
Neumann, P., Jakobi, I., Dolde, F., Burk, C., Reuter, R., Waldherr, G., Honert, J., Wolf, T., Brunner, A., Shim, J. H., et al. (2013) · Nano Letters · doi:10.1021/nl401216y · Cited by 785
Zhang, Y., Hong, G., Zhang, Y., Chen, G., Li, F., Dai, H., & Wang, Q. (2012) · ACS Nano · doi:10.1021/nn301218z · Cited by 765
Temperature Dependence of the Nitrogen-Vacancy Magnetic Resonance in Diamond
Acosta, V. M., Bauch, E., Ledbetter, M. P., Waxman, A., Bouchard, L.-S., & Budker, D. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070801 · Cited by 735
Research works printed but not linked: 9
- Bai, T.; Gu, N., Small 2016, 12 (34), 4590-4610.
- del Rosal, B.; Ximendes, E.; Rocha, U.; Jaque, D., Advanced Optical Materials 2017, 5 (1), 1600508.
- Jaque, D.; Vetrone, F., Nanoscale 2012, 4 (15), 4301-4326.
- Rusby, R.; Hudson, R.; Durieux, M., et al., Metrologia 1991, 28 (1), 9.
- Tuschel, D.; Adar, F., Spectroscopy 2016, 31 (12), 8-13.
- Brites, C. D. S.; Marin, R.; Suta, M., et al., Advanced Materials 2023, 35, 2302749. DOI 10.1002/adma.202302749. · DOI · Paper page
- Gu, Q.; Shanahan, L.; Hart, J. W., et al., ACS Nano 2023, 17 (20), 20034-20042. DOI
- So, F. T.-K.; Hariki, N.; Nemoto, M., et al., APL Materials 2024, 12 (5). DOI 10.1063/5.0201154. 107. Liu, C. F.; Leong, W. H.; Xia, K., et al., Natl Sci Rev 2021, 8 (5), nwaa194. DOI 10.1093/nsr/nwaa194. 108. Bradac, C.; Gao, W.; Forneris, J.; Trusheim, M. E.; Aharonovich, I., Nature communications 2019, 10 (1), 5625. DOI 10.1038/s41467-019-13332-w. 109. Fujiwara, M.; Uchida, G.; Ohki, I., et al., Carbon 2022, 198, 57-62. DOI https://doi.org/10.1016/j.carbon.2022.06.076. 110. Fedotov, I. V.; Solotenkov, M. A.; Pochechuev, M. S., et al., ACS Photonics 2020, 7 (12), 3353-3360. DOI 10.1021/acsphotonics.0c00706. 111. Plakhotnik, T.; Gruber, D., Physical Chemistry Chemical Physics 2010, 12 (33), 9751- 9756. DOI 10.1039/C001132K. 112. Tran, T. T.; Regan, B.; Ekimov, E. A., et al., Science Advances 2019, 5 (5), eaav9180. DOI doi:10.1126/sciadv.aav9180. 113. · doi:10.1016/j.carbon.2022.06.076
- Di, X.; Wang, D.; Su, Q. P., et al., Proceedings of the National Academy of Sciences 2022, 119 (45), e2207402119. DOI doi:10.1073/pnas.2207402119. 149. Fischer, L. H.; Harms, G. S.; Wolfbeis, O. S., Angewandte Chemie International Edition 2011, 50 (20), 4546-4551. DOI https://doi.org/10.1002/anie.201006835. 150. Yan, L.; Huang, J.; An, Z.; Zhang, Q.; Zhou, B., Nano Lett 2022, 22 (17), 7042-7048. DOI 10.1021/acs.nanolett.2c01931. 151. Sedlmeier, A.; Achatz, D. E.; Fischer, L. H.; Gorris, H. H.; Wolfbeis, O. S., Nanoscale 2012, 4 (22), 7090-7096. DOI 10.1039/C2NR32314A. 152. Rodrigues, E. M.; Gálico, D. A.; Lemes, M. A., et al., New Journal of Chemistry 2018, 42 (16), 13393-13405. DOI 10.1039/C8NJ02471E. 153. Xu, M.; Chen, D.; Huang, P., et al., Journal of Materials Chemistry C 2016, 4 (27), 6516-6524. DOI 10.1039/C6TC02218A. 154. Huang, G.; Wu, X.; Zhan, S.; Liu, Y., Journal of Materials Chemistry C 2022, 10 (13), 5190-5199. DOI 10.1039/D1TC05838J. 155. Wang, Y. F.; Liu, G. Y.; Sun, L. D., et al., ACS Nano 2013, 7 (8), 7200-6. DOI 10.1021/nn402601d. 156. Savchuk, O.; Carvajal, J.; Brites, C., et al., Nanoscale 2018, 10. DOI 10.1039/C7NR08758F. 157. Green, K.; Huang, K.; Pan, H.; Han, G.; Lim, S. F., Frontiers in Chemistry 2018, Volume 6 -2018. DOI 10.3389/fchem.2018.00416. 158. Yao, L.; Li, Y.; Xu, D., et al., New Journal of Chemistry 2019, 43 (9), 3848-3855. DOI 10.1039/C8NJ06385K. 159. Li, L.; Guo, C.; Jiang, S.; Agrawal, D. K.; Li, T., RSC Advances 2014, 4 (13), 6391- 6396. DOI 10.1039/C3RA47264G. 160. Liu, Y.; Duan, X.; Shin, H. J., et al., Nature 2021, 591 (7848), 43-53. DOI 10.1038/s41586-021-03339-z. 161. Taur, Y.; Wann, C. H.; Frank, D. J. In 25 nm CMOS design considerations, International Electron Devices Meeting 1998. Technical Digest (Cat. No.98CH36217), 6-9 Dec. 1998; 1998; pp 789-792. DOI 10.1109/IEDM.1998.746474. 162. Saïdi, E.; Babinet, N.; Lalouat, L., et al., Small 2011, 7 (2), 259-264. DOI https://doi.org/10.1002/smll.201001476. 163. Löw, P.; Kim, B.; Takama, N.; Bergaud, C., Small 2008, 4 (7), 908-914. DOI 10.1002/smll.200700581. 164. Hui, Y. Y.; Chen, O. Y.; Azuma, T., et al., The Journal of Physical Chemistry C 2019, 123 (24), 15366-15374. DOI 10.1021/acs.jpcc.9b04496. 165. van Swieten, T. P.; van Omme, T.; van den Heuvel, D. J., et al., ACS Applied Nano Materials 2021, 4 (4), 4208-4215. DOI 10.1021/acsanm.1c00657. 166. Chen, Y.; Tran, T. N.; Duong, N. M. H., et al., Acs Applied Materials & Interfaces 2020, 12 (22), 25464-25470. DOI 10.1021/acsami.0c05735. 167. · doi:10.1002/smll.201001476
Cited by
Mohammad, S. I., Vasudevan, A., Almomani, O., Madan, P., Upadhyay, A. K., Sharma, S., Mahmood, F., Nazeer, N., Meylikulov, S., & Bastani, H. (2026) · Results in Optics · doi:10.1016/j.rio.2026.101150
Metadata
- Authors
- Hossain, M. S., Nguyen, N. M., Mai, T. N. A., Doan, T. V., Chen, C., Su, Q. P., Liao, J., Chen, Y., Le-Van, Q., Dat, V. K., Dinh, T., Xu, X., & Tran, T. T.
- Affiliations
- University of Technology Sydney (AU)
- University of Hong Kong (HK)
- VinUniversity (VN)
- University of Southern Queensland (AU)
- Venue
- arXiv
- Publisher
- arXiv
- Published
- 2026
- ISSN
- 2331-8422 (ISSN-L)
- arXiv
- 2604.21186v1
- OpenAlex
- W7155521109
- Cited by
- 1
- References
- 99
- Citations by year
- 2026: 1
- Type
- posted content
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- cc-by-nc-nd
- arxiv.org/licenses/nonexclusive-distrib/1.0/
- Locations
- arXiv (Cornell University) (submittedVersion, cc-by-nc-nd)
- arXiv (Cornell University)
- Funders
- Australian Government
- Queensland Government
- Australian Research Council (DP240103127, DE220100487)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence Properties of Advanced Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- nanoscale thermometry, temperature sensing, excited-state dynamics, fluorescence linewidth, nanoelectronics, microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.