CoChat

Nanoscale Fluorescence Thermometry: Probes, Recent Advances and Emerging Directions

Open access

The DOI matches its DataCite record; 103 of the 110 references it cites were found in a registry or an index; none of the 94 sources its claims cite is checked for support yet.

Abstract

The transition of materials and devices to nanometer, atomic, and quantum scales makes thermal characterization increasingly challenging, driving the need for advanced nanoscale thermometry. Fluorescence nanothermometry has emerged as a powerful approach, enabling remote, spatially resolved temperature measurements with sub-micrometer-to-nanometer precision across applications in nanoelectronics, microfluidics, and biological systems. In these systems, temperature is inferred from variations in fluorescence observables, including spectral position, intensity, linewidth, and excited-state dynamics. This review provides a comprehensive and critical overview of fluorescence nanothermometry, covering fundamental mechanisms, material platforms, recent advances, and emerging applications. It further presents a critical evaluation of key challenges and discusses emerging strategies and future research directions toward achieving robust, real-time thermometry. It is anticipated that this review will stimulate further advances in material platforms and system design, accelerating the development of accurate, scalable, and application-ready nanoscale thermometers.

Overview

CoChat Summary

TL;DR

This review surveys nanoscale fluorescence (luminescence) thermometry, comparing it against IR, Raman, thermoreflectance, scanning thermal microscopy and plasmon-energy-expansion thermometry, and then focuses on diamond color centers (NV, GeV, SiV, SnV, PbV) as the most advanced probes, with QDs and upconversion nanoparticles (UCNPs) covered as complementary platforms. It closes with applications in micro/nanoelectronics, 3D thermal imaging and disease diagnosis, and argues that multiparametric readout combined with machine learning is the main route to reducing calibration burden and improving precision.

Key findings

  • Diamond color centers support both spin-based (ODMR) and all-optical thermometry: the NV ground-state zero-field splitting is ~2.88 GHz at room temperature with a temperature coefficient ΔD/ΔT ≈ −77 kHz °C⁻¹, and the NV zero-phonon line sits at 1.945 eV (637 nm). Reported temperature resolutions span from 76 μK Hz⁻¹ᐟ² (pulsed ODMR, 1 mm) and 10 mK Hz⁻¹ᐟ² (CW ODMR, bulk) down to ~1.4 K Hz⁻¹ᐟ² for in vivo *C. elegans* work, with spatial resolution reaching 3.7 nm for intracellular NV thermometry.
  • All-optical diamond thermometry avoids microwaves: SiV two-photon excitation achieved 6.6 mK Hz⁻¹ᐟ², multiparametric SiV analysis ~13 mK Hz⁻¹ᐟ² over sub-250 nm dimensions, and a fiber-coupled GeV probe monitored brain temperature in freely moving mice with accuracy better than 0.15 °C and 230 mK Hz⁻¹ᐟ² resolution.
  • UCNP thermometry is dominated by Boltzmann ratiometric schemes (typically Er³⁺ ²H₁₁/₂–⁴S₃/₂): Sedlmeier et al. achieved better than 0.5 °C resolution over 20–45 °C; the highest reported relative sensitivity cited is 9.52% K⁻¹, while KLuWO₄:Tm³⁺/Ho³⁺ under 808 nm excitation gave 2.8% K⁻¹ and 0.2 K resolution at 300 K. Water absorption at 980 nm is ~20× that at 800 nm.
  • Multiparametric/machine-learning approaches set the current performance ceiling: Maturi et al. reported a tenfold improvement over single-feature methods with 50% K⁻¹ relative sensitivity and uncertainty below 0.1 K; a combined Raman+PL ML model reached 0.7 K accuracy, 0.6 K·Hz⁻¹ᐟ² resolution and 0.04 K⁻¹ sensitivity.

Methods

  • Design: narrative/critical review with a comparative framework, not a primary experimental study. It classifies thermometry by physical mechanism (primary vs secondary), contact vs non-contact, and signal nature (optical vs non-optical), then defines figures of merit (absolute sensitivity Sₐ, relative sensitivity Sᵣ, temperature resolution η_T, ΔT_min, temporal resolution Δt_min).
  • Data: literature synthesis supported by two comparison tables — Table 2 (ODMR-based diamond thermometry by defect, modality, spatial resolution, temperature resolution, platform) and Table 3 (all-optical diamond thermometry by defect, optical observable, spatial and temperature resolution, platform) — plus a bibliometric analysis of Web of Science Core Collection records (1900–2025) using a luminescence/thermometry/diamond search query run on 19 March 2026.
  • Main analysis: qualitative comparison of probe platforms (diamond color centers, QDs, UCNPs) and application domains (micro/nanoelectronics, 3D thermal imaging, disease diagnosis), with market figures cited from third-party reports (temperature sensor market USD 9.93 billion in 2026 → USD 13.41 billion by 2031, 6.2% CAGR; optical temperature sensors to USD 3.5 billion by 2033, 7.8% CAGR).

Limitations

  • Stated by the paper: batch-to-batch variation in nanomaterial quality forces individual sensor calibration, which is impractical at scale; spatial resolution is diffraction-limited (~λ/2NA, roughly 200 nm for visible light and NA ≈ 1.4); self-absorption and scattering perturb PL intensity and spectral position; laser-induced self-heating is exacerbated by impurities, surface carbon and low-thermal-conductivity substrates; NV thermometry requires microwaves that are absorbed in biological media; nanodiamonds are sensitive to surface ligands, surfactants and trap states; and excitation-power mismatch between calibration and measurement biases ratiometric readouts, especially when the two bands arise from different-order processes (I₁ ∝ P vs I₂ ∝ P²). Thermal quenching of emission is also flagged as a general constraint.
  • Evident from the text: the review reports no new measurements or error analysis of its own, and its quantitative claims are inherited from the cited primary studies, so the tables' figures of merit are not independently verified. The supplied text is also visibly corrupted in places (truncated abstract, broken sentences, mangled table formatting and reference numbering), which limits confidence in some extracted numbers.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

DataCite · 10.48550/arxiv.2604.21186

Cites

103 of 110 references verified0 citation errors · 7 not checkable

Statistics

Nothing to recompute.

Figures

Raman Thermometry
Raman ThermometryCC-BY-NC-ND · From the PDF
Image 2
CC-BY-NC-ND · From the PDF
Fluorescence Thermometry
Fluorescence ThermometryCC-BY-NC-ND · From the PDF
Figure 2 Bibliometric analysis and applications of fluorescence nanothermometry (a) Annual number of publications and (b) annual number of citations for scientific papers retrieved from the Web of Science (Clarivate Analytics), Core Collection (1900 -2025). The search query was: (((luminescence OR luminescent OR fluorescence OR fluorescent) AND (thermometry OR
Figure 2 Bibliometric analysis and applications of fluorescence nanothermometry (a) Annual number of publications and (b) annual number of citations for scientific papers retrieved from the Web of Science (Clarivate Analytics), Core Collection (1900 -2025). The search query was: (((luminescence OR luminescent OR fluorescence OR fluorescent) AND (thermometry ORCC-BY-NC-ND · From the PDF
Image 5
CC-BY-NC-ND · From the PDF
Figure 4 All optical diamond thermometry (a) Atomic structure of group IV color centers exhibiting D3d symmetry in a split-vacancy configuration, where the group IV impurity atom (M, orange) is positioned between two adjacent carbon vacancies (V, white). [Reproduced from [108] under the terms of the CC-BY 4.0 license. Copyright 2019, Springer Nature], (b) Representative photoluminescence (PL) spectra of SiV⁻, GeV⁻, SnV⁻, and PbV⁻ color centers at room temperature. [Reproduced from ref [108] under the terms of the CC-BY 4.0 license. Copyright 2019, Springer Nature], (c) Energy-level diagram of group IV color centers illustrating the principle of all-optical thermometry. (d) Photoluminescence spectra of SiVcontaining nanodiamonds acquired at low and elevated temperatures, demonstrating a temperature-induced redshift of the ZPL. [Adapted with permission [109]. Copyright 2022,
Figure 4 All optical diamond thermometry (a) Atomic structure of group IV color centers exhibiting D3d symmetry in a split-vacancy configuration, where the group IV impurity atom (M, orange) is positioned between two adjacent carbon vacancies (V, white). [Reproduced from [108] under the terms of the CC-BY 4.0 license. Copyright 2019, Springer Nature], (b) Representative photoluminescence (PL) spectra of SiV⁻, GeV⁻, SnV⁻, and PbV⁻ color centers at room temperature. [Reproduced from ref [108] under the terms of the CC-BY 4.0 license. Copyright 2019, Springer Nature], (c) Energy-level diagram of group IV color centers illustrating the principle of all-optical thermometry. (d) Photoluminescence spectra of SiVcontaining nanodiamonds acquired at low and elevated temperatures, demonstrating a temperature-induced redshift of the ZPL. [Adapted with permission [109]. Copyright 2022,CC-BY-NC-ND · From the PDF
Figure 5 QDs-based fluorescence thermometry (a) Representative QD core materials plotted according to their emission wavelengths, highlighting their potential biological application windows. [Reproduced with permission [140]. Copyright 2005, Springer Nature] (b) Time resolved photoluminescence decay curves of didodecyl dimethylammonium bromide (DDAB)/tetraoctylammonium bromide (TOAB) capped CsPbBr3 QD film at different temperatures. [Reproduced with permission [138]. Copyright 2024, Elsevier] (c) Schematic energy band diagram of Mn²⁺ -doped ZnS quantum dots (QDs), along with temperaturedependent photoluminescence (PL) spectra recorded during heating and cooling cycles. The variation of the PL peak position and the integrated emission intensity as a function of
Figure 5 QDs-based fluorescence thermometry (a) Representative QD core materials plotted according to their emission wavelengths, highlighting their potential biological application windows. [Reproduced with permission [140]. Copyright 2005, Springer Nature] (b) Time resolved photoluminescence decay curves of didodecyl dimethylammonium bromide (DDAB)/tetraoctylammonium bromide (TOAB) capped CsPbBr3 QD film at different temperatures. [Reproduced with permission [138]. Copyright 2024, Elsevier] (c) Schematic energy band diagram of Mn²⁺ -doped ZnS quantum dots (QDs), along with temperaturedependent photoluminescence (PL) spectra recorded during heating and cooling cycles. The variation of the PL peak position and the integrated emission intensity as a function ofCC-BY-NC-ND · From the PDF
Figure 6 Upconversion nanoparticles (UCNPs) based fluorescence thermometry (a) Schematic illustration of the Yb/Ho/Ce:NaGdF4@Yb/Tm:NaYF4 core -shell nanostructure, along with temperature-dependent upconversion emission spectra recorded under 980 nm excitation and normalized to the green emission peak, and a histogram showing the integrated intensities of the blue, green, and red emission bands as a function of temperature. [Adapted with permission [153]. Copyright 2013, Royal Society of Chemistry (RSC)] (b) Variable-angle thermal sensing performance of the 1 mm PC@Au film@UCNPs composite, showing a schematic of the angle-
Figure 6 Upconversion nanoparticles (UCNPs) based fluorescence thermometry (a) Schematic illustration of the Yb/Ho/Ce:NaGdF4@Yb/Tm:NaYF4 core -shell nanostructure, along with temperature-dependent upconversion emission spectra recorded under 980 nm excitation and normalized to the green emission peak, and a histogram showing the integrated intensities of the blue, green, and red emission bands as a function of temperature. [Adapted with permission [153]. Copyright 2013, Royal Society of Chemistry (RSC)] (b) Variable-angle thermal sensing performance of the 1 mm PC@Au film@UCNPs composite, showing a schematic of the angle-CC-BY-NC-ND · From the PDF
Image 9
CC-BY-NC-ND · From the PDF
Figure 8 Three-dimensional temperature mapping with Fluorescence thermometry. (a) Rendered three-dimensional image of fluorescence lifetime data acquired from a 100-µm-long microchannel segment filled with a methanolic rhodamine B solution. Temperature profiles as
Figure 8 Three-dimensional temperature mapping with Fluorescence thermometry. (a) Rendered three-dimensional image of fluorescence lifetime data acquired from a 100-µm-long microchannel segment filled with a methanolic rhodamine B solution. Temperature profiles asCC-BY-NC-ND · From the PDF
Figure 9 Disease diagnosis with fluorescence thermometry. (a) Diagram summarizing medical conditions that result in localized or systemic thermal fluctuations. [Reproduced with permission [180]. Copyright 2025, John Wiley and Sons] (b) Early cancer detection using fluorescence thermometry. Time-dependent evolution of Δτ, tumor volume and the surface temperature difference between tumoral and adjacent healthy tissue following cancer cell
Figure 9 Disease diagnosis with fluorescence thermometry. (a) Diagram summarizing medical conditions that result in localized or systemic thermal fluctuations. [Reproduced with permission [180]. Copyright 2025, John Wiley and Sons] (b) Early cancer detection using fluorescence thermometry. Time-dependent evolution of Δτ, tumor volume and the surface temperature difference between tumoral and adjacent healthy tissue following cancer cellCC-BY-NC-ND · From the PDF

Verification

Claims the paper makes

0 Valid · 9 Not valid · 85 Not checked · 63 Own results and interpretations

73 more claims

Create a free account to see all 157 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 35
  • It may state two separate claims as one. 56

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

3 of 3

Citations

Cites

Show all 110 references

Research works printed but not linked: 9

  1. Bai, T.; Gu, N., Small 2016, 12 (34), 4590-4610.
  2. del Rosal, B.; Ximendes, E.; Rocha, U.; Jaque, D., Advanced Optical Materials 2017, 5 (1), 1600508.
  3. Jaque, D.; Vetrone, F., Nanoscale 2012, 4 (15), 4301-4326.
  4. Rusby, R.; Hudson, R.; Durieux, M., et al., Metrologia 1991, 28 (1), 9.
  5. Tuschel, D.; Adar, F., Spectroscopy 2016, 31 (12), 8-13.
  6. Brites, C. D. S.; Marin, R.; Suta, M., et al., Advanced Materials 2023, 35, 2302749. DOI 10.1002/adma.202302749. · DOI · Paper page
  7. Gu, Q.; Shanahan, L.; Hart, J. W., et al., ACS Nano 2023, 17 (20), 20034-20042. DOI
  8. So, F. T.-K.; Hariki, N.; Nemoto, M., et al., APL Materials 2024, 12 (5). DOI 10.1063/5.0201154. 107. Liu, C. F.; Leong, W. H.; Xia, K., et al., Natl Sci Rev 2021, 8 (5), nwaa194. DOI 10.1093/nsr/nwaa194. 108. Bradac, C.; Gao, W.; Forneris, J.; Trusheim, M. E.; Aharonovich, I., Nature communications 2019, 10 (1), 5625. DOI 10.1038/s41467-019-13332-w. 109. Fujiwara, M.; Uchida, G.; Ohki, I., et al., Carbon 2022, 198, 57-62. DOI https://doi.org/10.1016/j.carbon.2022.06.076. 110. Fedotov, I. V.; Solotenkov, M. A.; Pochechuev, M. S., et al., ACS Photonics 2020, 7 (12), 3353-3360. DOI 10.1021/acsphotonics.0c00706. 111. Plakhotnik, T.; Gruber, D., Physical Chemistry Chemical Physics 2010, 12 (33), 9751- 9756. DOI 10.1039/C001132K. 112. Tran, T. T.; Regan, B.; Ekimov, E. A., et al., Science Advances 2019, 5 (5), eaav9180. DOI doi:10.1126/sciadv.aav9180. 113. · doi:10.1016/j.carbon.2022.06.076
  9. Di, X.; Wang, D.; Su, Q. P., et al., Proceedings of the National Academy of Sciences 2022, 119 (45), e2207402119. DOI doi:10.1073/pnas.2207402119. 149. Fischer, L. H.; Harms, G. S.; Wolfbeis, O. S., Angewandte Chemie International Edition 2011, 50 (20), 4546-4551. DOI https://doi.org/10.1002/anie.201006835. 150. Yan, L.; Huang, J.; An, Z.; Zhang, Q.; Zhou, B., Nano Lett 2022, 22 (17), 7042-7048. DOI 10.1021/acs.nanolett.2c01931. 151. Sedlmeier, A.; Achatz, D. E.; Fischer, L. H.; Gorris, H. H.; Wolfbeis, O. S., Nanoscale 2012, 4 (22), 7090-7096. DOI 10.1039/C2NR32314A. 152. Rodrigues, E. M.; Gálico, D. A.; Lemes, M. A., et al., New Journal of Chemistry 2018, 42 (16), 13393-13405. DOI 10.1039/C8NJ02471E. 153. Xu, M.; Chen, D.; Huang, P., et al., Journal of Materials Chemistry C 2016, 4 (27), 6516-6524. DOI 10.1039/C6TC02218A. 154. Huang, G.; Wu, X.; Zhan, S.; Liu, Y., Journal of Materials Chemistry C 2022, 10 (13), 5190-5199. DOI 10.1039/D1TC05838J. 155. Wang, Y. F.; Liu, G. Y.; Sun, L. D., et al., ACS Nano 2013, 7 (8), 7200-6. DOI 10.1021/nn402601d. 156. Savchuk, O.; Carvajal, J.; Brites, C., et al., Nanoscale 2018, 10. DOI 10.1039/C7NR08758F. 157. Green, K.; Huang, K.; Pan, H.; Han, G.; Lim, S. F., Frontiers in Chemistry 2018, Volume 6 -2018. DOI 10.3389/fchem.2018.00416. 158. Yao, L.; Li, Y.; Xu, D., et al., New Journal of Chemistry 2019, 43 (9), 3848-3855. DOI 10.1039/C8NJ06385K. 159. Li, L.; Guo, C.; Jiang, S.; Agrawal, D. K.; Li, T., RSC Advances 2014, 4 (13), 6391- 6396. DOI 10.1039/C3RA47264G. 160. Liu, Y.; Duan, X.; Shin, H. J., et al., Nature 2021, 591 (7848), 43-53. DOI 10.1038/s41586-021-03339-z. 161. Taur, Y.; Wann, C. H.; Frank, D. J. In 25 nm CMOS design considerations, International Electron Devices Meeting 1998. Technical Digest (Cat. No.98CH36217), 6-9 Dec. 1998; 1998; pp 789-792. DOI 10.1109/IEDM.1998.746474. 162. Saïdi, E.; Babinet, N.; Lalouat, L., et al., Small 2011, 7 (2), 259-264. DOI https://doi.org/10.1002/smll.201001476. 163. Löw, P.; Kim, B.; Takama, N.; Bergaud, C., Small 2008, 4 (7), 908-914. DOI 10.1002/smll.200700581. 164. Hui, Y. Y.; Chen, O. Y.; Azuma, T., et al., The Journal of Physical Chemistry C 2019, 123 (24), 15366-15374. DOI 10.1021/acs.jpcc.9b04496. 165. van Swieten, T. P.; van Omme, T.; van den Heuvel, D. J., et al., ACS Applied Nano Materials 2021, 4 (4), 4208-4215. DOI 10.1021/acsanm.1c00657. 166. Chen, Y.; Tran, T. N.; Duong, N. M. H., et al., Acs Applied Materials & Interfaces 2020, 12 (22), 25464-25470. DOI 10.1021/acsami.0c05735. 167. · doi:10.1002/smll.201001476

Cited by

See all 1

Metadata

Authors
Hossain, M. S., Nguyen, N. M., Mai, T. N. A., Doan, T. V., Chen, C., Su, Q. P., Liao, J., Chen, Y., Le-Van, Q., Dat, V. K., Dinh, T., Xu, X., & Tran, T. T.
Affiliations
  • University of Technology Sydney (AU)
  • University of Hong Kong (HK)
  • VinUniversity (VN)
  • University of Southern Queensland (AU)
Venue
arXiv
Publisher
arXiv
Published
2026
ISSN
2331-8422 (ISSN-L)
OpenAlex
W7155521109
Cited by
1
References
99
Citations by year
2026: 1
Type
posted content
Language
en
Open access
Locations
  • arXiv (Cornell University) (submittedVersion, cc-by-nc-nd)
  • arXiv (Cornell University)
Funders
  • Australian Government
  • Queensland Government
  • Australian Research Council (DP240103127, DE220100487)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence Properties of Advanced Materials
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
Keywords
nanoscale thermometry, temperature sensing, excited-state dynamics, fluorescence linewidth, nanoelectronics, microfluidics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.