Human Body Composition
Abstract
The new edition of Human Body Composition is the most complete text in the burgeoning field of body composition research. The book covers the full range of methods to assess body composition, including dual-energy X-ray absorptiometry, electrical impedance, and imaging techniques. Maintaining the focus of the first edition as a definitive research guide, this resource incorporates updated information on methods and topics of biological importance.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Monitoring FFM alone can obscure meaningful changes in body composition since its composition comprises several components (e.g., water, protein, and minerals) not considered in the assessment.
“However, monitoring FFM alone can obscure meaningful changes in body composition since its composition comprises several components (e.g., water, protein, and minerals) not considered in the assessment [5, 6].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [5]
Potential contributors to inconsistent BOD POD measures include testing conditions, clothing worn in the BOD POD, and excessive facial or body hair.
“Potential contributors to inconsistent measures include testing conditions, clothing worn in the BOD POD, and excessive facial or body hair [50,51].”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [51]
Some BIA devices use single-frequency electrical currents, while others implement multi-frequency currents for greater penetration of different tissues and therefore with greater accuracy.
“BIA devices vary in sophistication and features; some use single-frequency electrical currents, while others implement multi-frequency currents for greater penetration of different tissues and therefore with greater accuracy (see Figure 2) [50,51].”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [51]
Both CT and MRI provide valid and in-depth body composition information.
“Both CT and MRI provide valid and in-depth body composition information, but these imaging techniques require expensive scanners, certified, trained technicians to perform the scans, analysis software, and expertise to quantify the tissue–organ level components of the produced images.”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [51]
CT and MRI have significantly impacted the scientific understanding of body composition and its relation to disease risk and outcome.
“The results from these imaging methods are considered the most accurate means of quantifying body composition at the tissue–organ level and have significantly impacted the scientific understanding of body composition and its relation to disease risk and outcome [51,73].”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [51]
HW is a foundational body composition method that was considered the "gold standard" for assessing FM and FFM for decades.
“Hydrostatic weighing (aka underwater weighing, hydrodensitometry) is a foundational body composition method that was considered the “gold standard” for assessing FM and FFM for decades.”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [51]
CT exposes the patient to a relatively low-dose of radiation, though greater than DXA.
“Similar to a DXA scan, a CT scan exposes the patient to a relatively low-dose of radiation, though it is greater than that of DXA.”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [51]
Results from CT and MRI are considered the most accurate means of quantifying body composition at the tissue-organ level.
“The results from these imaging methods are considered the most accurate means of quantifying body composition at the tissue–organ level and have significantly impacted the scientific understanding of body composition and its relation to disease risk and outcome [51,73].”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [51]
HW is based on Archimedes' principle, which states that when a body is immersed in water, it is buoyed by a counterforce equal to the weight of the displaced water.
“HW is based on Archimedes’ principle, which states that when a body is immersed in water, it is buoyed by a counterforce equal to the weight of the displaced water (see Figure 7) [50,51].”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [51]
CT and MRI provide cross-sectional images of specific body regions in the form of a plane through the body.
“CT and MRI are imaging techniques that provide cross-sectional images of specific body regions in the form of a plane through the body (see Figure 6) [51,72].”
From The Utility of Body Composition Assessment in Nutrition and Clinical Practice: An Overview of Current Methodology (2021) · cites this paper as [51]
The citation lists haven’t been fetched yet
Cited by 322
- Venue
- Human Kinetics eBooks
- Publisher
- Human Kinetics
- Published
- 2005
- OpenAlex
- W4238351031
- Cited by
- 322
- References
- 0
- Citations by year
- 2026: 5 · 2025: 21 · 2024: 19 · 2023: 19 · 2022: 17 · 2021: 18 · 2020: 12 · 2019: 16 · 2018: 24 · 2017: 21 · 2016: 13 · 2015: 21 · 2014: 26 · 2013: 14 · 2012: 14
- FWCI
- 12.18
- Type
- book
- Language
- en
- Open access
- closed
- Locations
- Human Kinetics eBooks (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Physiology › Nutrition and Health in Aging
- Keywords
- body composition, body composition assessment, dual-energy X-ray absorptiometry, bioimpedance, body composition imaging, anthropometry, fat-free mass, fat mass
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review