Field calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Health effects attributed to ambient fine particulate matter (PM2.5) now rank it among the risk factors with the highest health burdens in the world, but existing monitoring infrastructure cannot adequately characterize spatial and temporal variability in urban PM2.5 concentrations, nor in human population exposures. The development and evaluation of more portable and affordable monitoring instruments based on low-cost sensors may offer a means to supplement and extend existing infrastructure, increasing the density and coverage of empirical measurements and thereby improving exposure science and control. Here, we report on field calibrations of a custom-built, battery-operated aerosol monitoring instrument we developed using low-cost, off-the-shelf optical aerosol sensors. We calibrated our instruments using 1 h and 24 h PM2.5 data from a class III US EPA Federal Equivalent Method (FEM) PM2.5 β-attenuation monitor in continuous operation at a regulatory monitoring site in Oakland, California. We observed negligible associations with ambient humidity and temperature; linear corrections were sufficient to explain 60% of the variance in 1 h reference PM2.5 data and 72% of the variance in 24 h data. Performance at 1 h integration times was comparable to commercially available optical instruments costing considerably more. These findings warrant further exploration of the circumstances under which this class of aerosol sensors may profitably be deployed to generate improved PM2.5 data sets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lim, S. S., Vos, T., Flaxman, A. D., Danaei, G., Shibuya, K., Adair-Rohani, H., AlMazroa, M. A., Amann, M., Anderson, H. R., Andrews, K. G., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61766-8 · Cited by 11,805
Self-citationThe physical characteristics of sulfur aerosols
Whitby, K. T. (1978) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(78)90196-8 · Cited by 1,292
Combustion Aerosols: Factors Governing Their Size and Composition and Implications to Human Health
Lighty, J. S., Veranth, J. M., & Sarofim, A. F. (2000) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2000.10464197 · Cited by 1,169
A review and evaluation of intraurban air pollution exposure models
Jerrett, M., Arain, A., Kanaroglou, P., Beckerman, B., Potoglou, D., Sahsuvaroglu, T., Morrison, J., & Giovis, C. (2005) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500388 · Cited by 1,127
The Changing Paradigm of Air Pollution Monitoring
Snyder, E. G., Watkins, T. H., Solomon, P. A., Thoma, E. D., Williams, R. W., Hagler, G. S. W., Shelow, D., Hindin, D. A., Kilaru, V. J., & Preuss, P. W. (2013) · Environmental Science & Technology · doi:10.1021/es4022602 · Cited by 974
Visibility: Science and Regulation
Watson, J. G. (2002) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2002.10470813 · Cited by 929
Mead, M. I., Popoola, O. A. M., Stewart, G. B., Landshoff, P., Calleja, M., Hayes, M., Baldovi, J. J., McLeod, M. W., Hodgson, T. F., Dicks, J., et al. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.11.060 · Cited by 828
Brauer, M., Amann, M., Burnett, R. T., Cohen, A., Dentener, F., Ezzati, M., Henderson, S. B., Krzyzanowski, M., Martin, R. V., Van Dingenen, R., et al. (2012) · Environmental Science & Technology · doi:10.1021/es2025752 · Cited by 761
Mun, M., Reddy, S., Shilton, K., Yau, N., Burke, J., Estrin, D., Hansen, M., Howard, E., West, R., & Boda, P. (2009) · Proceedings of the 7th international conference on Mobile systems, applications, and services · doi:10.1145/1555816.1555823 · Cited by 662
Fine Particles and Coarse Particles: Concentration Relationships Relevant to Epidemiologic Studies
Wilson, W. E., & Suh, H. H. (1997) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1997.10464074 · Cited by 609
Cited by
Castell, N., Dauge, F. R., Schneider, P., Vogt, M., Lerner, U., Fishbain, B., Broday, D., & Bartonova, A. (2017) · Environment International · doi:10.1016/j.envint.2016.12.007 · Cited by 1,039
Aerosol Health Effects from Molecular to Global Scales
Shiraiwa, M., Ueda, K., Pozzer, A., Lammel, G., Kampf, C. J., Fushimi, A., Enami, S., Arangio, A. M., Fröhlich-Nowoisky, J., Fujitani, Y., et al. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b04417 · Cited by 673
End-user perspective of low-cost sensors for outdoor air pollution monitoring
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti, C., Yasar, A., & Rickerby, D. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.266 · Cited by 550
Ambient and laboratory evaluation of a low-cost particulate matter sensor
Kelly, K. E., Whitaker, J., Petty, A., Widmer, C., Dybwad, A., Sleeth, D., Martin, R., & Butterfield, A. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2016.12.039 · Cited by 498
Jiao, W., Hagler, G., Williams, R., Sharpe, R., Brown, R., Garver, D., Judge, R., Caudill, M., Rickard, J., Davis, M., et al. (2016) · Atmospheric Measurement Techniques · doi:10.5194/amt-9-5281-2016 · Cited by 484
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1100710 · Cited by 471
Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105833 · Cited by 426
Field evaluation of low-cost particulate matter sensors in high- and low-concentration environments
Zheng, T., Bergin, M. H., Johnson, K. K., Tripathi, S. N., Shirodkar, S., Landis, M. S., Sutaria, R., & Carlson, D. E. (2018) · Atmospheric Measurement Techniques · doi:10.5194/amt-11-4823-2018 · Cited by 418
Gao, M., Cao, J., & Seto, E. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.01.013 · Cited by 345
Self-citationPersonal exposure monitoring of PM 2.5 in indoor and outdoor microenvironments
Steinle, S., Reis, S., Sabel, C. E., Semple, S., Twigg, M. M., Braban, C. F., Leeson, S. R., Heal, M. R., Harrison, D., Lin, C., et al. (2015) · Science of The Total Environment · doi:10.1016/j.scitotenv.2014.12.003 · Cited by 337
Cross, E. S., Williams, L. R., Lewis, D. K., Magoon, G. R., Onasch, T. B., Kaminsky, M. L., Worsnop, D. R., & Jayne, J. T. (2017) · Atmospheric Measurement Techniques · doi:10.5194/amt-10-3575-2017 · Cited by 317
Assessment of air quality microsensors versus reference methods: The EuNetAir joint exercise
Borrego, C., Costa, A. M., Ginja, J., Amorim, M., Coutinho, M., Karatzas, K., Sioumis, T., Katsifarakis, N., Konstantinidis, K., De Vito, S., et al. (2016) · Atmospheric Environment · doi:10.1016/j.atmosenv.2016.09.050 · Cited by 274
Smart homes and the control of indoor air quality
Schieweck, A., Uhde, E., Salthammer, T., Salthammer, L. C., Morawska, L., Mazaheri, M., & Kumar, P. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.05.057 · Cited by 255
Assessing the accuracy of low-cost optical particle sensors using a physics-based approach
Hagan, D. H., & Kroll, J. H. (2020) · Atmospheric Measurement Techniques · doi:10.5194/amt-13-6343-2020 · Cited by 231
“…as shown by a number of recent laboratory and field-based evaluation studies (Crilley et al., 2018; Dacunto et al., 2015; Di Antonio et al., 2018; Holstius et al., 2014; Levy Zamora et al., 2019; Malings et al., 2020; Northcross et al., 2013; Sousan et al., 2016b, a; Wang et al., 2015), PM…”
BackgroundMethodBi, J., Wildani, A., Chang, H. H., & Liu, Y. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.9b06046 · Cited by 227
Inter-comparison of low-cost sensors for measuring the mass concentration of occupational aerosols
Sousan, S., Koehler, K., Thomas, G., Park, J. H., Hillman, M., Halterman, A., & Peters, T. M. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1162901 · Cited by 220
“In an urban setting, Holstius et al. (2014) observed that the [number or mass concentration measured with the DC1700 agreed well (R2 = 0.99) with that measured with an OPC (~ 12,000, GRIMM, Model 1.108, GRIMM Aerosol Technixk GmbH & Co., Ainring, Germany).”
InfluentialA Review of Low-Cost Particulate Matter Sensors from the Developers’ Perspectives
Alfano, B., Barretta, L., Del Giudice, A., De Vito, S., Di Francia, G., Esposito, E., Formisano, F., Massera, E., Miglietta, M. L., & Polichetti, T. (2020) · Sensors · doi:10.3390/s20236819 · Cited by 202
“[90] tested several LCPMS in outdoor conditions for the first time, collocated with regulatory grade analyzers.”
MethodKumar, P., Skouloudis, A. N., Bell, M., Viana, M., Carotta, M. C., Biskos, G., & Morawska, L. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2016.04.032 · Cited by 201
“weight and inexpensive (up to US $500) (Holstius et al., 2014).”
BackgroundMagi, B. I., Cupini, C., Francis, J., Green, M., & Hauser, C. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1619915 · Cited by 192
“5 shows that PA-II is biased high (Figure 2) which is consistent with similar collocation and lab comparisons (Holstius et al. 2014; Kelly et al. 2017; Wang et al. 2015; Zamora et al. 2019).”
BackgroundResult
Metadata
- Authors
- Holstius, D. M., Pillarisetti, A., Smith, K. R., & Seto, E.
- Venue
- Atmospheric Measurement Techniques
- Publisher
- Copernicus GmbH
- Published
- 2014-04-30
- Volume
- 7
- Issue
- 4
- Pages
- 1121-1131
- ISSN
- 1867-1381 (ISSN-L)
- 1867-8548
- OpenAlex
- W2140204557
- Cited by
- 312
- References
- 36
- FWCI
- 13.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.