The DOI matches its Crossref record.
Efficacy and Safety of 0.1% Cyclosporine a Cationic Emulsion in the Treatment of Severe Dry Eye Disease: A Multicenter Randomized Trial
Open accessAbstract
Purpose: The SANSIKA study was conducted to assess the treatment effect of 0.1% cyclosporine A cationic emulsion (CsA CE) eye drops on signs and symptoms of patients with severe dry eye disease (DED). Methods: This was a multicenter, randomized, double-masked, 2-parallel-arm, 6-month phase III study with a 6-month open-label treatment safety follow-up. Patients with severe DED with corneal fluorescein staining (CFS) grade 4 on the modified Oxford scale were randomized to receive once-daily CsA CE (Ikervis®) or its vehicle. Results: A total of 246 patients were randomized. The proportion of patients achieving ≥2 grades improvement in CFS and a 30% improvement in symptoms (Ocular Surface Disease Index [OSDI]) by month 6 was 28.6% with CsA CE vs 23.1% with vehicle (p = 0.326) (primary endpoint). Assessment of corneal damage showed greater improvement with CsA CE over vehicle in mean adjusted CFS change from baseline to month 6 (-1.764 vs −1.418, p = 0.037). There was a reduction in ocular surface inflammation assessed by human leukocyte antigen DR expression in favor of CsA CE at month 6 (p = 0.021). The mean OSDI change from baseline was −13.6 with CsA CE and −14.1 with vehicle at month 6 (p = 0.858). The main adverse event was instillation site pain (29.2% vs 8.9% in the CsA CE and vehicle groups, respectively), and it was mostly mild. Conclusions: CsA CE was well-tolerated and effective in improving corneal damage and ocular surface inflammation and confirmed the positive benefit-risk ratio of this new formulation of CsA for the treatment of severe keratitis in DED.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
TFOS DEWS II Management and Therapy Report
Jones, L., Downie, L. E., Korb, D., Benitez-del-Castillo, J. M., Dana, R., Deng, S. X., Dong, P. N., Geerling, G., Hida, R. Y., Liu, Y., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.05.006 · Cited by 1,422
Poloxamer 407/TPGS mixed micelles as promising carriers for cyclosporine ocular delivery
Grimaudo, M. A., Pescina, S., Padula, C., Santi, P., Concheiro, A., Alvarez-Lorenzo, C., & Nicoli, S. (2018) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.7b00939 · Cited by 138
Tauber, J., Schechter, B. A., Bacharach, J., Toyos, M. M., Smyth-Medina, R., Weiss, S. L., & Luchs, J. I. (2018) · Clinical ophthalmology · doi:10.2147/opth.s175065 · Cited by 73
Su, Y., Fan, X., & Pang, Y. (2023) · Biomaterials Science · doi:10.1039/d3bm00505d · Cited by 33
Metadata
- Authors
- Leonardi, A., Van Setten, G., Amrane, M., Ismail, D., Garrigue, J.-S., Figueiredo, F. C., & Baudouin, C.
- Venue
- European Journal of Ophthalmology
- Publisher
- SAGE Publications
- Published
- 2016-04-07
- Volume
- 26
- Issue
- 4
- Pages
- 287-296
- ISSN
- 1120-6721 (ISSN-L)
- 1724-6016
- OpenAlex
- W2318533725
- Cited by
- 194
- References
- 0
- FWCI
- 19.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.