The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Biological response to prosthetic debris
Open accessAbstract
Joint arthroplasty had revolutionized the outcome of orthopaedic surgery. Extensive and collaborative work of many innovator surgeons had led to the development of durable bearing surfaces, yet no single material is considered absolutely perfect. Generation of wear debris from any part of the prosthesis is unavoidable. Implant loosening secondary to osteolysis is the most common mode of failure of arthroplasty. Osteolysis is the resultant of complex contribution of the generated wear debris and the mechanical instability of the prosthetic components. Roughly speaking, all orthopedic biomaterials may induce a universal biologic host response to generated wear débris with little specific characteristics for each material; but some debris has been shown to be more cytotoxic than others. Prosthetic wear debris induces an extensive biological cascade of adverse cellular responses, where macrophages are the main cellular type involved in this hostile inflammatory process. Macrophages cause osteolysis indirectly by releasing numerous chemotactic inflammatory mediators, and directly by resorbing bone with their membrane microstructures. The bio-reactivity of wear particles depends on two major elements: particle characteristics (size, concentration and composition) and host characteristics. While any particle type may enhance hostile cellular reaction, cytological examination demonstrated that more than 70% of the debris burden is constituted of polyethylene particles. Comprehensive understanding of the intricate process of osteolysis is of utmost importance for future development of therapeutic modalities that may delay or prevent the disease progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bi, Y., Seabold, J. M., Kaar, S. G., Ragab, A. A., Goldberg, V. M., Anderson, J. M., & Greenfield, E. M. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.11.2082 · Cited by 227
Jobke, B., Milovanovic, P., Amling, M., & Busse, B. (2014) · Bone · doi:10.1016/j.bone.2013.10.024 · Cited by 123
Trindade, M. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00181-2 · Cited by 80
Cited by
Engineering Immunomodulatory Biomaterials To Tune the Inflammatory Response
Vishwakarma, A., Bhise, N. S., Evangelista, M. B., Rouwkema, J., Dokmeci, M. R., Ghaemmaghami, A. M., Vrana, N. E., & Khademhosseini, A. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.03.009 · Cited by 517
The potential impact of nano- and microplastics on human health: Understanding human health risks.
Winiarska, E., Jutel, M., & Zemelka-Wiacek, M. (2024) · Environmental Research · doi:10.1016/j.envres.2024.118535 · Cited by 470
Macrophages and bone inflammation
Gu, Q., Yang, H., & Shi, Q. (2017) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2017.05.002 · Cited by 221
Immune Organs and Immune Cells on a Chip: An Overview of Biomedical Applications
Morsink, M., Willemen, N., Leijten, J., Bansal, R., & Shin, S. (2020) · Micromachines · doi:10.3390/mi11090849 · Cited by 73
Klinder, A., Seyfarth, A., Hansmann, D., Bader, R., & Jonitz-Heincke, A. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.00831 · Cited by 32
Metadata
- Authors
- Bitar, D.
- Venue
- World Journal of Orthopedics
- Publisher
- Baishideng Publishing Group Inc.
- Published
- 2015
- Volume
- 6
- Issue
- 2
- Pages
- 172
- ISSN
- 2218-5836 (ISSN-L)
- OpenAlex
- W2044020235
- Cited by
- 237
- References
- 3
- FWCI
- 13.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biological response to prosthetic debris. https://app.cochat.ai/papers/10.5312/wjo.v6.i2.172
- The paper
- Bitar, D. (2015). Biological response to prosthetic debris. World Journal of Orthopedics. https://doi.org/10.5312/wjo.v6.i2.172
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.