Immune Organs and Immune Cells on a Chip: An Overview of Biomedical Applications
Open accessThe DOI matches its Crossref record; 120 of the 122 references it cites were found in a registry or an index.
Abstract
Understanding the immune system is of great importance for the development of drugs and the design of medical implants. Traditionally, two-dimensional static cultures have been used to investigate the immune system in vitro, while animal models have been used to study the immune system’s function and behavior in vivo. However, these conventional models do not fully emulate the complexity of the human immune system or the human in vivo microenvironment. Consequently, many promising preclinical findings have not been reproduced in human clinical trials. Organ-on-a-chip platforms can provide a solution to bridge this gap by offering human micro-(patho)physiological systems in which the immune system can be studied. This review provides an overview of the existing immune-organs-on-a-chip platforms, with a special emphasis on interorgan communication. In addition, future challenges to develop a comprehensive immune system-on-chip model are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


![Figure 3 Overview of various LNoC and BM-on-a-chip models. (A i,ii) Schematic of the bioreactor, where cell culture media and cell suspensions flow vertically, and the gas supply perfuses horizontally (left). Formation of microorganoids of DCs (red), B cells (red) and PBMCs (pink) after 7 days of perfusion [44]. Reproduced from Ref. [44] with the permission from Elsevier. (B i,ii) A LNoC composed of one main flow channel with 2 inlets and 2 outlets (left). Cross sectional view of a schematic showing the DC–T-cell interactions during flow. 1—Dendritic monolayer with LPS or OVA activation to mimic the inflammatory response, 2—T-cell loading and interactions with DCs. (right) [48]. Reproduced from Ref. [48] with permission from The Royal Society of Chemistry; (C–E) BM-on-a-chip from Sieber et al. [56]. Copyright 2017 Wiley. Used with permission from Sieber et al., Bone marrow-on-a-chip: Long-term culture of human hematopoietic stem cells in a three-dimensional microfluidic environment, Journal of Tissue Engineering and Regenerative Medicine, Wiley [56]; (C) scaffold used to culture the MSCs (top) compared with human BM (bottom); (D) schematic figure of the BM-on-a-chip with possibilities for other organ implantation, resulting in a multiorgan-on-a-chip device; (E) immune function of the device, depicting the stem cell factor immunoexpression and fibronectin immunoexpression, as well as the expression of certain BM markers and BM niche cells, such as nestin+ and osteopontin. APC—antigen presenting cells; CCS—central culture space; DC—dendritic cells; HFM—hollow fiber module; LPS—lipopolysaccharide; MPM—microporous membrane; OVA—ovalbumin; PCS—peripheral culture space; PDMS—polydimethylsiloxane.](https://figures.cochat.ai/paper-figures/5b406d7fea744c9f877f0f71695af895/immune-organs-and-immune-cells-on-a-chip-an-overview-of-biomedical-applications-figure-3.jpg)
![Figure 4 Schematic views of OoCs with immune cell components. (A) Inflammation-on-a-chip by Gopalakrishnan et al. [75] mimicking the cytokine gradient in a normal wound and the migration of immune cells. Reproduced from Ref. [75] with permission from The Royal Society of Chemistry. (B) skin-on-a-chip by Ramadan et al. [80] with dermal and epidermal layer, showing the interactions of DCs with the keratinocytes and (C) showing the expression of inflammatory cytokines IL-6 and IL-1β in the device with a keratinocyte (HaCaT) monoculture and a dendritic cell (U937) monoculture and the co-culture. Reproduced from Ref. [80] with permission from The Royal Society of Chemistry; (D) liver-on-a-chip by Gröger et al. [89]; the top layer consisting of endothelial cells and macrophages and the bottom layer consisting of hepatocytes and hepatic stellate cells. LPS is used to induce an inflammatory response and monocytes start migrating; (E) gut-on-a-chip by Kim et al. [90], showing the peristaltic motion as a result of the two vacuum chambers. This chip model is used to incorporate immune cells in later stages of the research [82]. Reproduced from Ref. [82] with permission from The Royal Society of Chemistry.](https://figures.cochat.ai/paper-figures/011bbf9bc8b4465a96173d86d4f83cdc/immune-organs-and-immune-cells-on-a-chip-an-overview-of-biomedical-applications-figure-4.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“3D models include neurospheroids [120], organ-on-a-chip devices [121], and engineered brain tissue [122], mimicking the brain’s complexity; however, they are more difficult to engineer and maintain [123].”
From Alzheimer's Disease: Treatment Strategies and Their Limitations. (2022) · cites this paper as [121]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The chemokine system in diverse forms of macrophage activation and polarization
MANTOVANI, A., SICA, A., SOZZANI, S., ALLAVENA, P., VECCHI, A., & LOCATI, M. (2004) · Trends in Immunology · doi:10.1016/j.it.2004.09.015 · Cited by 6,534 · cited 1×
“Depending on their phenotype, they can play important roles in both the pro- and anti-inflammatory processes by releasing either pro- or anti-inflammatory bioactive molecules [33].”
BackgroundOf Mice and Not Men: Differences between Mouse and Human Immunology
Mestas, J., & Hughes, C. C. W. (2004) · The Journal of Immunology · doi:10.4049/jimmunol.172.5.2731 · Cited by 3,822 · cited 2×
“However, there are still significant differences between the immune systems of rodents and fish models with humans, which can have detrimental results for clinical trials [13,15].”
BackgroundMesenchymal and haematopoietic stem cells form a unique bone marrow niche
Méndez-Ferrer, S., Michurina, T. V., Ferraro, F., Mazloom, A. R., MacArthur, B. D., Lira, S. A., Scadden, D. T., Ma’ayan, A., Enikolopov, G. N., & Frenette, P. S. (2010) · Nature · doi:10.1038/nature09262 · Cited by 3,374 · cited 1×
“The presence of nestin+ cells that support HSCs function and pluripotency [52,53] in the BM-on-a-chip suggested that the device could maintain HSC and hematopoietic function in vitro.”
BackgroundStructure and function of the spleen
Mebius, R. E., & Kraal, G. (2005) · Nature Reviews Immunology · doi:10.1038/nri1669 · Cited by 2,238 · cited 1×
“The spleen has two functional compartments: (1) the red pulp, containing the blood, which removes pathogens and cellular debris and (2) the white pulp, containing the lymphocytes, which initiates adaptive immune responses [63].”
BackgroundOverview of the immune response
Chaplin, D. D. (2010) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2009.12.980 · Cited by 2,235 · cited 4×
“Moreover, the adaptive immune cells can recruit innate mechanisms to completely thwart the invading microbes [27].”
BackgroundInfluentialSmith-Garvin, J. E., Koretzky, G. A., & Jordan, M. S. (2009) · Annual Review of Immunology · doi:10.1146/annurev.immunol.021908.132706 · Cited by 2,144 · cited 1×
“They activate upon exposure to the same antigen, initiating a quick and effective immune response to enable rapid neutralization of the pathogen [28,29].”
BackgroundRoles of the immune system in cancer: From tumor initiation to metastatic progression
Gonzalez, H., Hagerling, C., & Werb, Z. (2018) · Genes & Development · doi:10.1101/gad.314617.118 · Cited by 2,111 · cited 1×
“Thus, more research has focused on the fabrication of a tumor-microenvironment-on-chip (TMoC) to mimic and understand the intricate relationship between the TME and the immune system [97,98].”
BackgroundKim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734 · cited 3×
“[90], showing the peristaltic motion as a result of the two vacuum chambers.”
The multifaceted functions of neutrophils
Mayadas, T. N., Cullere, X., & Lowell, C. A. (2014) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-020712-164023 · Cited by 1,356 · cited 1×
“The granulocytes release large quantities of immunologically active molecules, such as reactive oxygen species (ROS) or enzymes, which can either kill invaders or activate other immune cells [31,32].”
BackgroundStructure and function of the immune system in the spleen
Lewis, S. M., Williams, A., & Eisenbarth, S. C. (2019) · Science Immunology · doi:10.1126/sciimmunol.aau6085 · Cited by 1,301 · cited 2×
“Its i mun logical functions vary from clearance of red blood cells ( s) t e atopoiesis [62].”
Background
Research works printed but not linked: 2
- Greenberg, S. (2020, September 12). A Concise History of Immunology. Available online: https://www.semanticscholar.org/paper/A-Concise-History-of-Immunology-Greenberg/9a3a8183f49ca41e83ae107c7cf16b5cb9a61d4a#citing-papers.
- Hoehn, E.N.M.A.K. (2006). The Lymphatic System and Lymphoid Organs and Tissues. Human Anatomy & Physiology, Pearson Educated Limited.
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Alzheimer's Disease: Treatment Strategies and Their Limitations.
Passeri, E., Elkhoury, K., Morsink, M., Broersen, K., Linder, M., Tamayol, A., Malaplate, C., Yen, F. T., & Arab-Tehrany, E. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms232213954 · Cited by 689
“3D models include neurospheroids [120], organ-on-a-chip devices [121], and engineered brain tissue [122], mimicking the brain’s complexity; however, they are more difficult to engineer and maintain [123].”
BackgroundSelf-citationShao, T., Verma, H. K., Pande, B., Costanzo, V., Ye, W., Cai, Y., & Bhaskar, L. V. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.751374 · Cited by 222
Advances in Organ-on-a-Chip Materials and Devices
Nahak, B. K., Mishra, A., Preetam, S., & Tiwari, A. (2022) · ACS Applied Bio Materials · doi:10.1021/acsabm.2c00041 · Cited by 134
Zhang, J., Tavakoli, H., Ma, L., Li, X., Han, L., & Li, X. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114365 · Cited by 114
Metadata
- Authors
- Morsink, M., Willemen, N., Leijten, J., Bansal, R., & Shin, S.
- Affiliations
- Brigham and Women's Hospital (US)
- University of Twente (NL)
- Corresponding author
- Shin, Su
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2020-09-12
- Volume
- 11
- Issue
- 9
- Pages
- 849
- ISSN
- 2072-666X (ISSN-L)
- PMC
- PMC7570325
- OpenAlex
- W3085475859
- Cited by
- 73
- References
- 122
- Citations by year
- 2026: 10 · 2025: 11 · 2024: 11 · 2023: 13 · 2022: 9 · 2021: 17 · 2020: 2
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Micromachines (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- University of Twente Research Information (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- University of Twente Research Information (submittedVersion, cc-by)
- Funders
- National Institutes of Health (R01AR074234, R21EB026824)
- American Heart Association (19IPLOI34660079)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- organ-on-a-chip, immune organs, immune cells, inter-organ communication, drug development, biomedical implants, translational research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immune Organs and Immune Cells on a Chip: An Overview of Biomedical Applications. https://app.cochat.ai/papers/10.3390/mi11090849
- The paper
- Morsink, M., Willemen, N., Leijten, J., Bansal, R., & Shin, S. (2020). Immune Organs and Immune Cells on a Chip: An Overview of Biomedical Applications. Micromachines. https://doi.org/10.3390/mi11090849
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.