Abstract

Understanding the immune system is of great importance for the development of drugs and the design of medical implants. Traditionally, two-dimensional static cultures have been used to investigate the immune system in vitro, while animal models have been used to study the immune system’s function and behavior in vivo. However, these conventional models do not fully emulate the complexity of the human immune system or the human in vivo microenvironment. Consequently, many promising preclinical findings have not been reproduced in human clinical trials. Organ-on-a-chip platforms can provide a solution to bridge this gap by offering human micro-(patho)physiological systems in which the immune system can be studied. This review provides an overview of the existing immune-organs-on-a-chip platforms, with a special emphasis on interorgan communication. In addition, future challenges to develop a comprehensive immune system-on-chip model are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/mi11090849

Cites

120 of 120 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 (A) Timeline of the important events in the history of immunology from 430 BC until 2020; (B) rapidly increasing publications for immune related microfluidic technologies and their applications in the biomedical engineering fields.
Figure 1 (A) Timeline of the important events in the history of immunology from 430 BC until 2020; (B) rapidly increasing publications for immune related microfluidic technologies and their applications in the biomedical engineering fields.CC BY · PubMed Central
Figure 2 Schematic of major parameters that influence the immunomodulation of biomaterials and tissue engineered constructs. ECM—extracellular matrix; IL—interleukin; LPS—lipopolysaccharide; PDGF—platelet-derived growth factor; TNFα—tumor necrosis factor α; VEGF—vascular endothelial growth factor.
Figure 2 Schematic of major parameters that influence the immunomodulation of biomaterials and tissue engineered constructs. ECM—extracellular matrix; IL—interleukin; LPS—lipopolysaccharide; PDGF—platelet-derived growth factor; TNFα—tumor necrosis factor α; VEGF—vascular endothelial growth factor.CC BY · PubMed Central
Figure 3 Overview of various LNoC and BM-on-a-chip models. (A i,ii) Schematic of the bioreactor, where cell culture media and cell suspensions flow vertically, and the gas supply perfuses horizontally (left). Formation of microorganoids of DCs (red), B cells (red) and PBMCs (pink) after 7 days of perfusion [44]. Reproduced from Ref. [44] with the permission from Elsevier. (B i,ii) A LNoC composed of one main flow channel with 2 inlets and 2 outlets (left). Cross sectional view of a schematic showing the DC–T-cell interactions during flow. 1—Dendritic monolayer with LPS or OVA activation to mimic the inflammatory response, 2—T-cell loading and interactions with DCs. (right) [48]. Reproduced from Ref. [48] with permission from The Royal Society of Chemistry; (C–E) BM-on-a-chip from Sieber et al. [56]. Copyright 2017 Wiley. Used with permission from Sieber et al., Bone marrow-on-a-chip: Long-term culture of human hematopoietic stem cells in a three-dimensional microfluidic environment, Journal of Tissue Engineering and Regenerative Medicine, Wiley [56]; (C) scaffold used to culture the MSCs (top) compared with human BM (bottom); (D) schematic figure of the BM-on-a-chip with possibilities for other organ implantation, resulting in a multiorgan-on-a-chip device; (E) immune function of the device, depicting the stem cell factor immunoexpression and fibronectin immunoexpression, as well as the expression of certain BM markers and BM niche cells, such as nestin+ and osteopontin. APC—antigen presenting cells; CCS—central culture space; DC—dendritic cells; HFM—hollow fiber module; LPS—lipopolysaccharide; MPM—microporous membrane; OVA—ovalbumin; PCS—peripheral culture space; PDMS—polydimethylsiloxane.
Figure 3 Overview of various LNoC and BM-on-a-chip models. (A i,ii) Schematic of the bioreactor, where cell culture media and cell suspensions flow vertically, and the gas supply perfuses horizontally (left). Formation of microorganoids of DCs (red), B cells (red) and PBMCs (pink) after 7 days of perfusion [44]. Reproduced from Ref. [44] with the permission from Elsevier. (B i,ii) A LNoC composed of one main flow channel with 2 inlets and 2 outlets (left). Cross sectional view of a schematic showing the DC–T-cell interactions during flow. 1—Dendritic monolayer with LPS or OVA activation to mimic the inflammatory response, 2—T-cell loading and interactions with DCs. (right) [48]. Reproduced from Ref. [48] with permission from The Royal Society of Chemistry; (C–E) BM-on-a-chip from Sieber et al. [56]. Copyright 2017 Wiley. Used with permission from Sieber et al., Bone marrow-on-a-chip: Long-term culture of human hematopoietic stem cells in a three-dimensional microfluidic environment, Journal of Tissue Engineering and Regenerative Medicine, Wiley [56]; (C) scaffold used to culture the MSCs (top) compared with human BM (bottom); (D) schematic figure of the BM-on-a-chip with possibilities for other organ implantation, resulting in a multiorgan-on-a-chip device; (E) immune function of the device, depicting the stem cell factor immunoexpression and fibronectin immunoexpression, as well as the expression of certain BM markers and BM niche cells, such as nestin+ and osteopontin. APC—antigen presenting cells; CCS—central culture space; DC—dendritic cells; HFM—hollow fiber module; LPS—lipopolysaccharide; MPM—microporous membrane; OVA—ovalbumin; PCS—peripheral culture space; PDMS—polydimethylsiloxane.CC BY · PubMed Central
Figure 4 Schematic views of OoCs with immune cell components. (A) Inflammation-on-a-chip by Gopalakrishnan et al. [75] mimicking the cytokine gradient in a normal wound and the migration of immune cells. Reproduced from Ref. [75] with permission from The Royal Society of Chemistry. (B) skin-on-a-chip by Ramadan et al. [80] with dermal and epidermal layer, showing the interactions of DCs with the keratinocytes and (C) showing the expression of inflammatory cytokines IL-6 and IL-1β in the device with a keratinocyte (HaCaT) monoculture and a dendritic cell (U937) monoculture and the co-culture. Reproduced from Ref. [80] with permission from The Royal Society of Chemistry; (D) liver-on-a-chip by Gröger et al. [89]; the top layer consisting of endothelial cells and macrophages and the bottom layer consisting of hepatocytes and hepatic stellate cells. LPS is used to induce an inflammatory response and monocytes start migrating; (E) gut-on-a-chip by Kim et al. [90], showing the peristaltic motion as a result of the two vacuum chambers. This chip model is used to incorporate immune cells in later stages of the research [82]. Reproduced from Ref. [82] with permission from The Royal Society of Chemistry.
Figure 4 Schematic views of OoCs with immune cell components. (A) Inflammation-on-a-chip by Gopalakrishnan et al. [75] mimicking the cytokine gradient in a normal wound and the migration of immune cells. Reproduced from Ref. [75] with permission from The Royal Society of Chemistry. (B) skin-on-a-chip by Ramadan et al. [80] with dermal and epidermal layer, showing the interactions of DCs with the keratinocytes and (C) showing the expression of inflammatory cytokines IL-6 and IL-1β in the device with a keratinocyte (HaCaT) monoculture and a dendritic cell (U937) monoculture and the co-culture. Reproduced from Ref. [80] with permission from The Royal Society of Chemistry; (D) liver-on-a-chip by Gröger et al. [89]; the top layer consisting of endothelial cells and macrophages and the bottom layer consisting of hepatocytes and hepatic stellate cells. LPS is used to induce an inflammatory response and monocytes start migrating; (E) gut-on-a-chip by Kim et al. [90], showing the peristaltic motion as a result of the two vacuum chambers. This chip model is used to incorporate immune cells in later stages of the research [82]. Reproduced from Ref. [82] with permission from The Royal Society of Chemistry.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 120 references

Research works printed but not linked: 2

  1. Greenberg, S. (2020, September 12). A Concise History of Immunology. Available online: https://www.semanticscholar.org/paper/A-Concise-History-of-Immunology-Greenberg/9a3a8183f49ca41e83ae107c7cf16b5cb9a61d4a#citing-papers.
  2. Hoehn, E.N.M.A.K. (2006). The Lymphatic System and Lymphoid Organs and Tissues. Human Anatomy & Physiology, Pearson Educated Limited.

Cited by

See all 73

Metadata

Authors
Morsink, M., Willemen, N., Leijten, J., Bansal, R., & Shin, S.
Affiliations
  • Brigham and Women's Hospital (US)
  • University of Twente (NL)
Corresponding author
Shin, Su
Venue
Micromachines
Publisher
MDPI AG
Published
2020-09-12
Volume
11
Issue
9
Pages
849
ISSN
2072-666X (ISSN-L)
OpenAlex
W3085475859
Cited by
73
References
122
Citations by year
2026: 10 · 2025: 11 · 2024: 11 · 2023: 13 · 2022: 9 · 2021: 17 · 2020: 2
FWCI
0.86
Type
journal article
Language
en
Open access
Locations
  • Micromachines (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • University of Twente Research Information (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • University of Twente Research Information (submittedVersion, cc-by)
Funders
  • National Institutes of Health (R01AR074234, R21EB026824)
  • American Heart Association (19IPLOI34660079)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
organ-on-a-chip, immune organs, immune cells, inter-organ communication, drug development, biomedical implants, translational research

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Immune Organs and Immune Cells on a Chip: An Overview of Biomedical Applications. https://app.cochat.ai/papers/10.3390/mi11090849
The paper
Morsink, M., Willemen, N., Leijten, J., Bansal, R., & Shin, S. (2020). Immune Organs and Immune Cells on a Chip: An Overview of Biomedical Applications. Micromachines. https://doi.org/10.3390/mi11090849

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.