The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Wear Debris in Total Joint Replacements
Abstract
In vivo degradation of prosthetic implant materials is increasingly recognized as a major factor limiting the durability of total joint arthroplasty. In vivo degradation occurs primarily by means of wear processes that can generate large quantities of particulate debris. This debris can stimulate an adverse local host response leading to periprosthetic bone loss, which can compromise implant fixation and bone stock. The authors review the basic mechanisms of implant degradation and the host response to particulate degradation products, particularly in the context of the pathogenesis of osteolysis. Submicron polyethylene particles (mean size, 0.5 um) are the dominant type of wear particle present in periprosthetic tissues associated with uncemented hip replacements. Polyethylene wear can be minimized by improving the quality of the polyethylene, avoiding use of large-diameter (greater than 28 mm) femoral heads in total hip arthroplasty, and improving the design and fabrication of modular connections, which can be important sources of three-body wear particles. Advances in the understanding of the basic mechanisms of osteolysis are critical to the development of preventive measures that will minimize the clinical impact of this phenomenon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
Self-citation
Cited by
URBAN, R. M., JACOBS, J. J., TOMLINSON, M. J., GAVRILOVIC, J., BLACK, J., & PEOC'H, M. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200004000-00002 · Cited by 787
Self-citationTheoleyre, S., Wittrant, Y., Tat, S. K., Fortun, Y., Redini, F., & Heymann, D. (2004) · Cytokine & Growth Factor Reviews · doi:10.1016/j.cytogfr.2004.06.004 · Cited by 663
Calcium phosphate coatings on magnesium alloys for biomedical applications: A review
Shadanbaz, S., & Dias, G. J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.10.016 · Cited by 651
Osteoarthritis: New Insights. Part 2: Treatment Approaches
Felson, D. T., Lawrence, R. C., Hochberg, M. C., McAlindon, T., Dieppe, P. A., Minor, M. A., Blair, S. N., Berman, B. M., Fries, J. F., Weinberger, M., et al. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-9-200011070-00015 · Cited by 506
Self-citationOsteoblast proliferation and maturation by bisphosphonates
Im, G.-I., Qureshi, S. A., Kenney, J., Rubash, H. E., & Shanbhag, A. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.024 · Cited by 393
Self-citation
Metadata
- Authors
- Jacobs, J. J., Shanbhag, A., Glant, T. T., Black, J., & Galante, J. O.
- Venue
- Journal of the American Academy of Orthopaedic Surgeons
- Published
- 1994-07
- Volume
- 2
- Issue
- 4
- Pages
- 212-220
- ISSN
- 1067-151X (ISSN-L)
- OpenAlex
- W2170143415
- Cited by
- 235
- References
- 1
- FWCI
- 8.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wear Debris in Total Joint Replacements. https://app.cochat.ai/papers/10.5435/00124635-199407000-00004
- The paper
- Jacobs, J. J., Shanbhag, A., Glant, T. T., Black, J., & Galante, J. O. (1994). Wear Debris in Total Joint Replacements. Journal of the American Academy of Orthopaedic Surgeons. https://doi.org/10.5435/00124635-199407000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.