Wear Debris in Total Joint Replacements
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
In vivo degradation of prosthetic implant materials is increasingly recognized as a major factor limiting the durability of total joint arthroplasty. In vivo degradation occurs primarily by means of wear processes that can generate large quantities of particulate debris. This debris can stimulate an adverse local host response leading to periprosthetic bone loss, which can compromise implant fixation and bone stock. The authors review the basic mechanisms of implant degradation and the host response to particulate degradation products, particularly in the context of the pathogenesis of osteolysis. Submicron polyethylene particles (mean size, 0.5 um) are the dominant type of wear particle present in periprosthetic tissues associated with uncemented hip replacements. Polyethylene wear can be minimized by improving the quality of the polyethylene, avoiding use of large-diameter (greater than 28 mm) femoral heads in total hip arthroplasty, and improving the design and fabrication of modular connections, which can be important sources of three-body wear particles. Advances in the understanding of the basic mechanisms of osteolysis are critical to the development of preventive measures that will minimize the clinical impact of this phenomenon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schmalzried, T. P., Jasty, M., & Harris, W. H. (1992) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199274060-00006 · Cited by 989 · cited 1×
“For example, the finding of UHMWPE debris in the vicinity of the distal aspect of a well-fixed THA femoral stem suggests a communication between the joint space and the most remote regions of the femoral periprosthetic space.(20) In noncircumferentially coated devices and press-fit devices without a coating, a space c…”
BackgroundGoldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., OʼNeil, D. A., & Harris, W. H. (1983) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198365050-00001 · Cited by 849
Reactions of the articular capsule to wear products of artificial joint prostheses
Willert, H. ‐., & Semlitsch, M. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110202 · Cited by 822 · cited 2×
“In summary, it is hypothesized that wear-particle generation and migration into the joint cavity and periprosthetic space may stimulate macrophage recruitment and phagocytosis, as proposed by Willert and Semlitsch.(1) This, in turn, stimulates secretion of various cellular mediators that interact and modify the activi…”
BackgroundBanaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_20 · Cited by 783
Gilbert, J. L., Buckley, C. A., & Jacobs, J. J. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271210 · Cited by 685 · cited 3×
“This phenomenon has been described in femoral THA components with tapers and heads made of similar metals (cobalt-base alloy) as well as in tapers and heads made of the mixed-metal combination of a cobalt-base-alloy head on a titanium-base-alloy neck.(21) This process involves a number of variables, including the meta…”
BackgroundInfluentialSelf-citationJiranek, W. A., Machado, M., Jasty, M., Jevsevar, D., Wolfe, H. J., Goldring, S. R., Goldberg, M. J., & Harris, W. H. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00007 · Cited by 436 · cited 1×
“Recently, more sophisticated methods have been applied to study the problem of periprosthetic bone loss.(18) These include immunohistochemistry and in situ hybridization, both of which are powerful tools that can help unravel the basic cellular mechanisms leading to the observed clinical entities of focal osteolysis a…”
MethodHaynes, D. R., Rogers, S. D., Hay, S., Pearcy, M. J., & Howie, D. W. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00004 · Cited by 425
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
Self-citationEndosteal erosion in association with stable uncemented femoral components.
Maloney, W. J., Jasty, M., Harris, W. H., Galante, J. O., & Callaghan, J. J. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072070-00011 · Cited by 369
Self-citationAnthony, P., Gie, G., Howie, C., & Ling, R. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b6.2246300 · Cited by 319 · cited 3×
“of polymethylmethacrylate particles (or voids representing the location of particles dissolved during tissue processing).(8) Particle Analysis”
BackgroundInfluential
Cited by
URBAN, R. M., JACOBS, J. J., TOMLINSON, M. J., GAVRILOVIC, J., BLACK, J., & PEOC'H, M. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200004000-00002 · Cited by 787
Self-citationTheoleyre, S., Wittrant, Y., Tat, S. K., Fortun, Y., Redini, F., & Heymann, D. (2004) · Cytokine & Growth Factor Reviews · doi:10.1016/j.cytogfr.2004.06.004 · Cited by 663
Calcium phosphate coatings on magnesium alloys for biomedical applications: A review
Shadanbaz, S., & Dias, G. J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.10.016 · Cited by 651
Osteoarthritis: New Insights. Part 2: Treatment Approaches
Felson, D. T., Lawrence, R. C., Hochberg, M. C., McAlindon, T., Dieppe, P. A., Minor, M. A., Blair, S. N., Berman, B. M., Fries, J. F., Weinberger, M., et al. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-9-200011070-00015 · Cited by 506
Self-citationOsteoblast proliferation and maturation by bisphosphonates
Im, G.-I., Qureshi, S. A., Kenney, J., Rubash, H. E., & Shanbhag, A. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.024 · Cited by 393
Self-citationJacobs, J. J., Roebuck, K. A., Archibeck, M., Hallab, N. J., & Glant, T. T. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200112000-00008 · Cited by 367
Self-citationGrimaud, E., Soubigou, L., Couillaud, S., Coipeau, P., Moreau, A., Passuti, N., Gouin, F., Redini, F., & Heymann, D. (2003) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63560-2 · Cited by 282
Concentration‐ and composition‐dependent effects of metal ions on human MG‐63 osteoblasts
Hallab, N. J., Vermes, C., Messina, C., Roebuck, K. A., Glant, T. T., & Jacobs, J. J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10106 · Cited by 280
Self-citationVermes, C., Chandrasekaran, R., Jacobs, J. J., Galante, J. O., Roebuck, K. A., & Glant, T. T. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200102000-00007 · Cited by 220
Self-citationSpinal Implant Debris-Induced Osteolysis
Hallab, N. J., Cunningham, B. W., & Jacobs, J. J. (2003) · Spine · doi:10.1097/00007632-200310151-00006 · Cited by 201
“Histologic And Morphologic Features of Particles Osteolysis, or periprosthetic bone loss, has been more commonly described in association with total joint replacement (TJA) than with spinal instrumentation.(27) There are common histopathologic features in associaS126 Spine • Volume 28 • Number 20S • 2003”
BackgroundSelf-citationTumor necrosis factor‐α/nuclear transcription factor‐κB signaling in periprosthetic osteolysis
Schwarz, E. M., Lu, A. P., Goater, J. J., Benz, E. B., Kollias, G., Rosier, R. N., Puzas, J. E., & O'Keefe, R. J. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180321 · Cited by 199
Computational wear prediction of a total knee replacement from in vivo kinematics
Fregly, B. J., Sawyer, W. G., Harman, M. K., & Banks, S. A. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.013 · Cited by 175
“Wear of ultra-high molecular weight polyethylene (UHMWPE) in total knee replacements remains a major limitation to the longevity of these clinically successful devices (Peters et al., 1992; Cadambi et al., 1994; Jacobs et al., 1994; Sharkey et al., 2002).”
Background
Metadata
- Authors
- Jacobs, J. J., Shanbhag, A., Glant, T. T., Black, J., & Galante, J. O.
- Venue
- Journal of the American Academy of Orthopaedic Surgeons
- Published
- 1994-07
- Volume
- 2
- Issue
- 4
- Pages
- 212-220
- ISSN
- 1067-151X (ISSN-L)
- OpenAlex
- W2170143415
- Cited by
- 235
- References
- 15
- FWCI
- 8.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.