The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Reliability and Usefulness of the Pressure Pain Threshold Measurement in Patients with Myofascial Pain
Open accessAbstract
OBJECTIVE: To assess the usefulness of a pressure algometer to measure pressure pain threshold (PPT) for diagnosis of myofascial pain syndrome (MPS) in the upper extremity and trunk muscles. METHOD: A group of 221 desk workers complaining of upper body pain participated in this study. Five physiatrists made the diagnosis of MPS using physical examination and PPT measurements. PPT measurements were determined for several muscles in the back and upper extremities. Mean PPT data for gender, side, and dominant hand groups were analyzed. Sensitivity and specificity of Fischer's standard method were evaluated. PPT cut-off values for each muscle group were determined using an ROC curve. RESULTS: Cronbach's alpha for each muscle was very high. The PPT in men was higher than in females, and the PPT in the left side was higher than in the right side for all muscles tested (p<0.05). There was no significant difference in PPT for all muscles between dominant and non-dominant hand groups. Diagnosis of MPS based on Fischer's standard showed relatively high specificity and poor sensitivity. CONCLUSION: The digital pressure algometer showed high reliability. PPT might be a useful parameter for assessing a treatment's effect, but not for use in diagnosis or even as a screening method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BONICA, J. J. (1954) · The American Journal of the Medical Sciences · doi:10.1097/00000441-195405000-00015 · Cited by 1,464
Fischer, A. A. (1987) · Pain · doi:10.1016/0304-3959(87)90089-3 · Cited by 958
Chesterton, L. S., Sim, J., Wright, C. C., & Foster, N. E. (2007) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e318154b6ae · Cited by 691
Gender differences in pressure pain threshold in healthy humans
Chesterton, L. S., Barlas, P., Foster, N. E., Baxter, D. G., & Wright, C. C. (2003) · Pain · doi:10.1016/s0304-3959(02)00330-5 · Cited by 460
Reliability of the pressure algometer as a measure of myofascial trigger point sensitivity
Reeves, J. L., Jaeger, B., & Graff-Radford, S. B. (1986) · Pain · doi:10.1016/0304-3959(86)90117-x · Cited by 389
Reliability and Validity of a Pressure Algometer
Kinser, A. M., Sands, W. A., & Stone, M. H. (2009) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31818f051c · Cited by 378
GRIP TEST: The Use of a Dynamometer with Adjustable Handle Spacings
Bechtol, C. O. (1954) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-195436040-00013 · Cited by 371
Pressure threshold meter: its use for quantification of tender spots.
Fischer, A. A. (1986) · PubMed · Cited by 285
Sola, A. E., & Williams, R. L. (1956) · Neurology · doi:10.1212/wnl.6.2.91 · Cited by 156
Algometry. Measuring pain threshold, method and characteristics in healthy subjects
Hogeweg, J. A., Langereis, M. M., Bernards, A. T. M., Faber, J. A. J., & Helders, P. J. M. (1992) · Journal of Rehabilitation Medicine · doi:10.2340/165019779299103 · Cited by 101
Cited by
Frawley, H., Shelly, B., Morin, M., Bernard, S., Bø, K., Digesu, G. A., Dickinson, T., Goonewardene, S., McClurg, D., Rahnama'i, M. S., et al. (2021) · Neurourology and Urodynamics · doi:10.1002/nau.24658 · Cited by 246
Hao, Y., Wu, Y., Wang, S., Wang, C., Qu, S., Li, L., Yu, G., Liu, Z., Zhao, Z., Fan, P., et al. (2021) · Journal of Ethnopharmacology · doi:10.1016/j.jep.2021.113780 · Cited by 19
Metadata
- Authors
- Park, G., Kim, C. W., Park, S. B., Kim, M. J., & Jang, S. H.
- Venue
- Annals of Rehabilitation Medicine
- Published
- 2011
- Volume
- 35
- Issue
- 3
- Pages
- 412
- ISSN
- 2234-0645 (ISSN-L)
- OpenAlex
- W2089764140
- Cited by
- 280
- References
- 14
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability and Usefulness of the Pressure Pain Threshold Measurement in Patients with Myofascial Pain. https://app.cochat.ai/papers/10.5535/arm.2011.35.3.412
- The paper
- Park, G., Kim, C. W., Park, S. B., Kim, M. J., & Jang, S. H. (2011). Reliability and Usefulness of the Pressure Pain Threshold Measurement in Patients with Myofascial Pain. Annals of Rehabilitation Medicine. https://doi.org/10.5535/arm.2011.35.3.412
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.