The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Reliability and Validity of a Pressure Algometer
Abstract
Algometers are devices that can be used to identify the pressure and/or force eliciting a pressure-pain threshold. It has been noted in pressure-pain threshold studies that the rate at which manual force is applied should be consistent to provide the greatest reliability. This study tested the reliability and construct validity of an algometer (1000-Hz sampling rate) by manually applying pressure on a force plate (500-Hz sampling rate): 10 sets of 5 applications to 80 N and 1 set of 5 applications to each force level: 20, 30, 40, 50, 60, 70, 80, 90, 100, and 110 N. The investigator had previously become familiar with and practiced with the algometer. The handheld algometer had a 1-cm2 round rubber application surface, and the maximum force reading was compared with maximum force readings by the force plate using SEM and t-tests. Force-time curves were analyzed for average slope representing rate of force application. Average Pearson (r) correlations between the maximum force reading of the algometer and force plate were excellent in both trials to 80 N (r = 0.990) and the incremental trials (r = 0.999). The application of force was reasonably constant, with slopes averaging 6.8 +/- 0.932 N x s-1. The SEE was 0.323 N. In conclusion, with previous familiarization and practice, an investigator may have high reliability in the rate of force application. The device itself was also highly correlated with readings from a force plate and, therefore, may be considered valid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reliability of Clinical Pressure-Pain Algometric Measurements Obtained on Consecutive Days
Nussbaum, E. L., & Downes, L. (1998) · Physical Therapy · doi:10.1093/ptj/78.2.160 · Cited by 416
Cited by
Park, G., Kim, C. W., Park, S. B., Kim, M. J., & Jang, S. H. (2011) · Annals of Rehabilitation Medicine · doi:10.5535/arm.2011.35.3.412 · Cited by 280
Hermesdorf, M., Berger, K., Baune, B. T., Wellmann, J., Ruscheweyh, R., & Wersching, H. (2016) · The Journal of Pain · doi:10.1016/j.jpain.2016.01.474 · Cited by 140
Pollatos, O., Füstös, J., & Critchley, H. D. (2012) · Pain · doi:10.1016/j.pain.2012.04.030 · Cited by 127
On the interaction of self-regulation, interoception and pain perception
Weiss, S., Sack, M., Henningsen, P., & Pollatos, O. (2014) · Psychopathology · doi:10.1159/000365107 · Cited by 112
Pain and self-harm: a systematic review
Kirtley, O. J., O’Carroll, R. E., & O’Connor, R. C. (2016) · Journal of Affective Disorders · doi:10.1016/j.jad.2016.05.068 · Cited by 78
Metadata
- Authors
- Kinser, A. M., Sands, W. A., & Stone, M. H.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2009-01
- Volume
- 23
- Issue
- 1
- Pages
- 312-314
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W2070956946
- Cited by
- 378
- References
- 1
- FWCI
- 8.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability and Validity of a Pressure Algometer. https://app.cochat.ai/papers/10.1519/jsc.0b013e31818f051c
- The paper
- Kinser, A. M., Sands, W. A., & Stone, M. H. (2009). Reliability and Validity of a Pressure Algometer. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0b013e31818f051c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.