Non-invasive respiration rate monitoring using a single COTS TX-RX pair
The DOI matches its OpenAlex record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Abstract—Respiratory rate is an important vital sign that can indicate progression of illness but to also predict rapid decline in health. For the purpose, non-contact monitoring systems are becoming more popular due to the self-evident increase in patient comfort. As a cost effective solution for non-invasive breathing monitoring, utilizing the received signal strength measurements of inexpensive transceivers has been proposed. However, the applicability of the available solutions is limited since they rely on numerous sensors. In this work, considerable improvement is made, and a respiratory rate monitoring system based on a single commercial off-the-shelf transmitter-receiver pair is presented. Methods that enable estimation and enhance the accuracy are presented and their effects are evaluated. Moreover, it is empirically demonstrated that the performance of the system is comparable to the accuracy of a high-end device for 3-4 orders of magnitude less price; achieving mean absolute error of 0.12 breaths per minute in the most realistic scenario of the experiments. Index Terms—received signal strength, COTS transceivers, wireless sensor networks, respiratory rate monitoring I.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Cook, T. M., Woodall, N., Harper, J., & Benger, J. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer059 · Cited by 1,065
Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients.
Fieselmann, J. F., Hendryx, M. S., Helms, C. M., & Wakefield, D. S. (1993) · Journal of General Internal Medicine · doi:10.1007/bf02600071 · Cited by 399
Cited by
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916
Wang, H., Zhang, D., Ma, J., Wang, Y., Wang, Y., Wu, D., Gu, T., & Xie, B. (2016) · Proceedings of the 2016 ACM International Joint Conference on Pervasive and Ubiquitous Computing · doi:10.1145/2971648.2971744 · Cited by 501
Tracking Vital Signs During Sleep Leveraging Off-the-shelf WiFi
Liu, J., Wang, Y., Chen, Y., Yang, J., Chen, X., & Cheng, J. (2015) · Proceedings of the 16th ACM International Symposium on Mobile Ad Hoc Networking and Computing · doi:10.1145/2746285.2746303 · Cited by 481
FarSense: Pushing the Range Limit of WiFi-based Respiration Sensing with CSI Ratio of Two Antennas
Zeng, Y., Wu, D., Xiong, J., Yi, E., Gao, R., & Zhang, D. (2019) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3351279 · Cited by 469
Emotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461
Metadata
- Authors
- Kaltiokallio, O., Yi̇ği̇tler, H., Jäntti, R., & Patwari, N.
- Published
- 2014-04-15
- Pages
- 59-70
- DOI
- 10.5555/2602339.2602347
- OpenAlex
- W2073718740
- Cited by
- 78
- References
- 3
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive respiration rate monitoring using a single COTS TX-RX pair. https://app.cochat.ai/papers/10.5555/2602339.2602347
- The paper
- Kaltiokallio, O., Yi̇ği̇tler, H., Jäntti, R., & Patwari, N. (2014). Non-invasive respiration rate monitoring using a single COTS TX-RX pair. https://doi.org/10.5555/2602339.2602347
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.