The DOI matches its Crossref record.
Impact of Clinical Assessment on Use of Data from Unattended Limited Monitoring as Opposed to Full-in lab PSG in Sleep Disordered Breathing
Open accessAbstract
Study objectives We examined agreement among multiple sleep clinicians when presented with clinical data plus the full tracings and data obtained from unattended limited monitoring (ULM) or a full polysomnography (PSG). Methods Subjects included 66 patients with complaints of sleep disordered breathing (SDB) and 19 volunteers willing to undergo 2 nights of ULM followed by PSG. Two assessment packages were created for each subject with identical clinical history (Hx) and ARES Symptom Questionnaire, plus the electronic record of signals collected on the ARES Unicorder (Hx+ULM) or on the PSG (Hx+PSG). Data were presented to 4 sleep-trained clinicians for diagnosis and treatment recommendation. For agreement on diagnosis and treatment, comparisons were made between clinicians using ULM or PSG, and within clinicians comparing both techniques. Results For diagnosis, agreement between pairs of clinicians using Hx+PSG ranged from 74% to 86% and 66% to 85% when using Hx+ULM. For treatment, agreement using Hx+PSG ranged from 74% to 86% and 58% to 77% when using Hx+ULM. Agreement between clinicians was highest in the subjects with the highest RDI and fell off markedly at the lowest RDI, irrespective of whether the clinicians used the Hx+PSG or Hx+ULM. This pattern was also seen for the decisions made by an individual clinician using Hx+ULM vs. Hx+PSG. Conclusion Our data show that sleep clinicians have significant disagreements for diagnosis even when presented with the "gold standard" of a PSG and clinical data. Agreement was high when the SDB index was elevated and lower when the SDB index was in the mild-to-moderate range, regardless of the technique used to obtain it.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In a high-risk population using cutoffs of AHI ≥ 5, AHI ≥ 15 and AHI ≥ 30, accuracy of 2-3 channel HSAT devices ranged from 81% to 93%, 72% to 87%, and 71% to 90%, respectively.
“In a high-risk population using cutoffs of AHI ≥ 5,95–97 AHI ≥ 15,95–99 and AHI ≥ 30,96,97 accuracy ranged from 81% to 93%, 72% to 87%, and 71% to 90%, respectively.”
From Clinical Practice Guideline for Diagnostic Testing for Adult Obstructive Sleep Apnea: An American Academy of Sleep Medicine Clinical Practice Guideline (2017) · cites this paper as [99]
The Comparison of SDB Indices Using PSG and ULM section reports 86% overall diagnostic agreement at an RDI cutoff of >15/h and 85% at an AHI4% cutoff of >10/h. These findings support diagnostic agreement for unattended monitoring, but the paper does not report accuracy ranges at the cited AHI ≥5, ≥15, and ≥30 cutoffs. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 12
- Ballester E, Solans M, Vila X, et al. Evaluation of a portable respiratory recording device for detecting apnoeas and hypopnoeas in subjects from a general population. Eur Respir J 2000;16:123–7. · DOI
- Dingli K, Coleman EL, Vennelle M, et al. Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome. Eur Respir J 2003;21:253–9. · DOI
- Ayappa I. Comparison of limited monitoring using a nasal-canula flow signal to full polysomnography in sleep-disordered breathing. Sleep 2004;27:1171–9. · DOI
- Westbrook PR. Description and validation of the apnea risk evaluation system: a novel method to diagnose sleep apnea-hypopnea in the home. Chest 2005;128:2166–75. · DOI
- Yin M, Miyazaki S, Ishikawa K. Evaluation of type 3 portable monitoring in unattended home setting for suspected sleep apnea: factors that may affect its accuracy. Otolaryngol Head Neck Surg 2006;134:204–9. · DOI · Paper page
- Ayappa I, Norman RG, Seelall V, Rapoport DM. Validation of a self-applied unattended monitor for sleep disordered breathing. J Clin Sleep Med 2008;4:26–37. · DOI · Paper page
- Collop NA, Anderson WM, Boehlecke B, et al. Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine. J Clin Sleep Med 2007;3:737–47. · DOI · Paper page
- Johns MW. Daytime sleepiness, snoring, and obstructive sleep apnea. The Epworth Sleepiness Scale. Chest 1993;103:30–6. · DOI
- Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force. Sleep 1999;22:667–89. · DOI · Paper page
- Rechtschaffen A, Kales A, A manual of standardized terminology, techniques and scoring system for sleep stages of human subjects. University of California, Los Angeles: Brain Information Service; 1968.
- Iber C, The AASM manual for the scoring of sleep and associated events: rules terminology and technical specifications. 1st ed. Westchester, IL: American Academy of Sleep Medicine; 2007.
- Iber C, Redline S, Kaplan Gilpin AM, et al. Polysomnography performed in the unattended home versus the attended laboratory setting--Sleep Heart Health Study methodology. Sleep 2004;27:536–40. · DOI
Cited by
Sorted by citations
Kapur, V. K., Auckley, D. H., Chowdhuri, S., Kuhlmann, D. C., Mehra, R., Ramar, K., & Harrod, C. G. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6506 · Cited by 3,253
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
El Shayeb, M., Topfer, L.-A., Stafinski, T., Pawluk, L., & Menon, D. (2014) · Canadian Medical Association Journal · doi:10.1503/cmaj.130952 · Cited by 237
Metadata
- Authors
- Masdeu, M. J., Ayappa, I., Hwang, D., Mooney, A. M., & Rapoport, D. M.
- Affiliations
- New York University (US)
- NYU Langone Health (US)
- Corresponding author
- Rapoport, David M.
- Venue
- Journal of Clinical Sleep Medicine
- Published
- 2010-02-15
- Volume
- 6
- Issue
- 1
- Pages
- 51-58
- ISSN
- 1550-9389 (ISSN-L)
- 1550-9397
- PMC
- PMC2823276
- OpenAlex
- W2395673381
- Cited by
- 25
- References
- 0
- Citations by year
- 2022: 2 · 2020: 3 · 2017: 2 · 2015: 1 · 2014: 12 · 2013: 1 · 2012: 1
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Clinical Sleep Medicine (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Center for Research Resources (M01RR000096)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- sleep-disordered breathing, home sleep apnea testing, polysomnography, sleep apnea severity, respiratory disturbance index, treatment guidelines
- MeSH terms
- Adult, Aged, Female, Humans, Male, Medical History Taking, Middle Aged, Sleep Apnea Syndromes, Snoring, Reproducibility of Results, Observer Variation, Polysomnography, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review