CoChat

Response of Genioglossus Muscle to Increasing Chemical Drive in Sleeping Obstructive Apnea Patients

Open access
Loewen, Andrea H.S., Ostrowski, Michele, Laprairie, John, Maturino, Frances, Hanly, Patrick J., Younes, Magdy · 2011 · Sleep
Cited by 64

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: Subjects with a collapsible upper airway must activate their pharyngeal dilators sufficiently in response to increasing chemical drive if they are to maintain airway patency without arousal from sleep. Little is known about the response of pharyngeal dilators to increasing chemical drive in these subjects. We wished to determine, in obstructive apnea patients, the response of the genioglossus to increasing chemical drive and the contribution of mechanoreceptor feedback to this response. DESIGN: Physiological study. SETTING: University-based sleep laboratory. PATIENTS: 20 patients with obstructive apnea. INTERVENTIONS: Genioglossus activity was monitored during overnight polysomnography on optimal continuous positive airway pressure (CPAP). Intermittently, inspired gases were altered to produce different levels of ventilatory stimulation. CPAP was then briefly reduced to 1.0 cm H(2)O (dial-down), inducing an obstruction. MEASUREMENTS AND RESULTS: Without mechanoreceptor feedback (i.e., on CPAP) the increase in genioglossus activity as ventilation increased from 6.1 ± 1.4 to 16.1 ± 4.8 L/min was modest (ΔTonic activity 0.3% ± 0.5%maximum; ΔPhasic activity 1.7% ± 3.4%maximum). Genioglossus activity increased immediately upon dial-down, reflecting mechanoreceptor feedback, but only when ventilation before dial-down exceeded a threshold value. This threshold varied among patients and, once surpassed, genioglossus activity increased briskly with further increases in chemical drive (1.1% ± 0.84%GG(MAX) per L/min increase in V(E)). CONCLUSIONS: In sleeping obstructive apnea patients: (1) Mechanoreceptor feedback is responsible for most of the genioglossus response to chemical drive. (2) Mechanoreceptor feedback is effective only above a threshold chemical drive, which varies greatly among patients. These findings account in part for the highly variable relation between pharyngeal mechanical abnormalities and apnea severity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.1162

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 64

Metadata

Authors
Loewen, A. H. S., Ostrowski, M., Laprairie, J., Maturino, F., Hanly, P. J., & Younes, M.
Venue
Sleep
Published
2011-08
Volume
34
Issue
8
Pages
1061-1073
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2316458468
Cited by
64
References
11
FWCI
3.47
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.