The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Continuous Positive Airway Pressure: Evaluation of a Novel Therapy for Patients with Acute Ischemic Stroke
Open accessAbstract
BACKGROUND: New approaches are needed to treat patients with stroke. Among acute ischemic stroke patients, our primary objectives were to describe the prevalence of sleep apnea and demonstrate the feasibility of providing auto-titrating continuous positive airway pressure (auto-CPAP). A secondary objective was to examine the effect of auto-CPAP on stroke severity. METHODS: Stroke patients randomized to the intervention group received 2 nights of auto-CPAP, but only those with evidence of sleep apnea received auto-CPAP for the remainder of the 30-day period. Intervention patients received polysomnography 30 days post-stroke. Control patients received polysomnography at baseline and after 30 days. Acceptable auto-CPAP adherence was defined as ≥ 4 h/night for ≥ 75% nights. Change in stroke severity was assessed comparing the NIH Stroke Scale (NIHSS) at baseline versus at 30 days. RESULTS: The 2 groups (intervention N = 31, control N = 24) had similar baseline stroke severity (both median NIHSS, 3.0). Among patients with complete polysomnography data, the majority had sleep apnea: baseline, 13/15 (86.7%) control patients; 30 days, 24/35 (68.6%) control and intervention patients. Intervention patients had greater improvements in NIHSS (-3.0) than control patients (-1.0); P = 0.03. Among patients with sleep apnea, greater improvement was observed with increasing auto-CPAP use: -1.0 for control patients not using auto-CPAP; -2.5 for intervention patients with some auto-CPAP use; and -3.0 for intervention patients with acceptable auto-CPAP adherence. CONCLUSIONS: The majority of acute stroke patients had sleep apnea. Auto-CPAP was well tolerated, appears to improve neurological recovery from stroke, and may represent a new therapeutic approach for selected patients with acute cerebral infarction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Marin, J. M., Carrizo, S. J., Vicente, E., & Agusti, A. G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71141-7 · Cited by 4,678
Continuous positive airways pressure for obstructive sleep apnoea in adults
Giles, T., Lasserson, T., Smith, B., White, J., Wright, J., & Cates, C. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001106.pub2 · Cited by 1,001
Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home
Massie, C. A., McArdle, N., Hart, R. W., Schmidt-Nowara, W. W., Lankford, A., Hudgel, D. W., Gordon, N., & Douglas, N. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200201-022oc · Cited by 177
Cited by
Kernan, W. N., Ovbiagele, B., Black, H. R., Bravata, D. M., Chimowitz, M. I., Ezekowitz, M. D., Fang, M. C., Fisher, M., Furie, K. L., Heck, D. V., et al. (2014) · Stroke · doi:10.1161/str.0000000000000024 · Cited by 5,170
Self-citationHeart Disease and Stroke Statistics—2013 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828124ad · Cited by 5,292
Self-citationKleindorfer, D. O., Towfighi, A., Chaturvedi, S., Cockroft, K. M., Gutierrez, J., Lombardi-Hill, D., Kamel, H., Kernan, W. N., Kittner, S. J., Leira, E. C., et al. (2021) · Stroke · doi:10.1161/str.0000000000000375 · Cited by 3,237
Self-citationWozniak, D. R., Lasserson, T. J., & Smith, I. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007736.pub2 · Cited by 379
Prevalence of sleep-disordered breathing after stroke and TIA: A meta-analysis
Seiler, A., Camilo, M., Korostovtseva, L., Haynes, A. G., Brill, A.-K., Horvath, T., Egger, M., & Bassetti, C. L. (2019) · Neurology · doi:10.1212/wnl.0000000000006904 · Cited by 234
Metadata
- Authors
- Bravata, D. M., Concato, J., Fried, T., Ranjbar, N., Sadarangani, T., McClain, V., Struve, F., Zygmunt, L., Knight, H. J., Lo, A., Richerson, G. B., Gorman, M., Williams, L. S., Brass, L. M., Agostini, J., Mohsenin, V., Roux, F., & Yaggi, H. K.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-09
- Volume
- 34
- Issue
- 9
- Pages
- 1271-1277
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2120186847
- Cited by
- 163
- References
- 4
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Positive Airway Pressure: Evaluation of a Novel Therapy for Patients with Acute Ischemic Stroke. https://app.cochat.ai/papers/10.5665/sleep.1254
- The paper
- Bravata, D. M., Concato, J., Fried, T., Ranjbar, N., Sadarangani, T., McClain, V., Struve, F., Zygmunt, L., Knight, H. J., Lo, A., Richerson, G. B., Gorman, M., Williams, L. S., Brass, L. M., Agostini, J., Mohsenin, V., Roux, F., & Yaggi, H. K. (2011). Continuous Positive Airway Pressure: Evaluation of a Novel Therapy for Patients with Acute Ischemic Stroke. Sleep. https://doi.org/10.5665/sleep.1254
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.