CoChat

Obstructive Sleep Apnea is Associated with Increased Chemoreflex Sensitivity in Patients with Metabolic Syndrome

Open access
Trombetta, Ivani C., Maki-Nunes, Cristiane, Toschi-Dias, Edgar, Alves, Maria-Janieire N. N., Rondon, Maria Urbana P. B., Cepeda, Felipe X., Drager, Luciano F., Braga, Ana Maria F. W., Lorenzi-Filho, Geraldo, Negrao, Carlos E. · 2013 · Sleep
Cited by 68

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) is often observed in patients with metabolic syndrome (MetS). In addition, the association of MetS and OSA substantially increases sympathetic nerve activity. However, the mechanisms involved in sympathetic hyperactivation in patients with MetS + OSA remain to be clarified. We tested the hypothesis that chemoreflex sensitivity is heightened in patients with MetS and OSA. DESIGN: Prospective clinical study. PARTICIPANTS: Forty-six patients in whom MetS was newly diagnosed (ATP-III) were allocated into: (1) MetS + OSA (n = 24, 48 ± 1.8 yr); and (2) MetS - OSA (n = 22, 44 ± 1.7 yr). Eleven normal control subjects were also studied (C, 47 ± 2.3 yr). MEASUREMENTS: OSA was defined as an apnea-hypopnea index ≥ 15 events/hr (polysomnography). Muscle sympathetic nerve activity (MSNA) was measured by microneurography technique. Peripheral chemoreflex sensitivity was assessed by inhalation of 10% oxygen and 90% nitrogen (carbon dioxide titrated), and central chemoreflex sensitivity by 7% carbon dioxide and 93% oxygen. RESULTS: Physical characteristics and MetS measures were similar between MetS + OSA and MetS - OSA. MSNA was higher in MetS + OSA patients compared with MetS - OSA and C (33 ± 1.3 versus 28 ± 1.2 and 18 ± 2.2 bursts/min, P < 0.05). Isocapnic hypoxia caused a greater increase in MSNA in MetS + OSA than MetS - OSA and C (P = 0.03). MSNA in response to hyperoxic hypercapnia was greater in MetS + OSA compared with C (P = 0.005). Further analysis showed a significant association between baseline MSNA and peripheral (P < 0.01) and central (P < 0.01) chemoreflex sensitivity. Min ventilation in response to hyperoxic hypercapnia was greater in MetS + OSA compared with C (P = 0.001). CONCLUSION: OSA increases sympathetic peripheral and central chemoreflex response in patients with MetS, which seems to explain, at least in part, the increase in sympathetic nerve activity in these patients. In addition, OSA increases ventilatory central chemoreflex response in patients with MetS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.2298

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Trombetta, I. C., Maki-Nunes, C., Toschi-Dias, E., Alves, M.-J. N. N., Rondon, M. U. P. B., Cepeda, F. X., Drager, L. F., Braga, A. M. F. W., Lorenzi-Filho, G., & Negrao, C. E.
Venue
Sleep
Published
2013-01
Volume
36
Issue
1
Pages
41-49
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2052083646
Cited by
68
References
3
FWCI
2.83
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.