CoChat

Electroencephalographic Power Spectral Density Profile of the Orexin Receptor Antagonist Suvorexant in Patients with Primary Insomnia and Healthy Subjects

Open access
Ma, Junshui, Svetnik, Vladimir, Snyder, Ellen, Lines, Christopher, Roth, Thomas, Herring, W. Joseph · 2014 · Sleep
Cited by 48

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: Suvorexant, an orexin receptor antagonist, improves sleep in healthy subjects (HS) and patients with insomnia. We compared the electroencephalographic (EEG) power spectral density (PSD) profile of suvorexant with placebo using data from a phase 2 trial in patients with insomnia. We also compared suvorexant's PSD profile with the profiles of other insomnia treatments using data from 3 HS studies. DESIGN: Phase 2 trial--randomized, double-blind, two-period (4 w per period) crossover. HS studies--randomized, double-blind, crossover. SETTING: Sleep laboratories. PARTICIPANTS: Insomnia patients (n = 229) or HS (n = 124). INTERVENTIONS: Phase 2 trial--suvorexant 10 mg, 20 mg, 40 mg, 80 mg, placebo; HS study 1--suvorexant 10 mg, 50 mg, placebo; HS study 2--gaboxadol 15 mg, zolpidem 10 mg, placebo; HS study 3--trazodone 150 mg, placebo. MEASUREMENTS AND RESULTS: The PSD of the EEG signal at 1-32 Hz of each PSG recording during nonrapid eye movement (NREM) and rapid eye movement (REM) sleep were calculated. The day 1 and day 28 PSD profiles of suvorexant at all four doses during NREM and REM sleep in patients with insomnia were generally flat and close to 1.0 (placebo) at all frequencies. The day 1 PSD profile of suvorexant in HS was similar to that in insomnia patients. In contrast, the other three drugs had distinct PSD profiles in HS that differed from each other. CONCLUSIONS: Suvorexant at clinically effective doses had limited effects on power spectral density compared with placebo in healthy subjects and in patients with insomnia, in contrast to the three comparison insomnia treatments. These findings suggest the possibility that antagonism of the orexin pathway might lead to improvements in sleep without major changes in the patient's neurophysiology as assessed by electroencephalographic.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.4068

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 48

Metadata

Authors
Ma, J., Svetnik, V., Snyder, E., Lines, C., Roth, T., & Herring, W. J.
Venue
Sleep
Published
2014-10-01
Volume
37
Issue
10
Pages
1609-1619
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2322091572
Cited by
48
References
3
FWCI
6.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.