CoChat

The Effect of Body Position on Physiological Factors that Contribute to Obstructive Sleep Apnea

Open access
Joosten, Simon A., Edwards, Bradley A., Wellman, Andrew, Turton, Anthony, Skuza, Elizabeth M., Berger, Philip J., Hamilton, Garun S. · 2015 · Sleep
Cited by 118

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) resolves in lateral sleep in 20% of patients. However, the effect of lateral positioning on factors contributing to OSA has not been studied. We aimed to measure the effect of lateral positioning on the key pathophysiological contributors to OSA including lung volume, passive airway anatomy/collapsibility, the ability of the airway to stiffen and dilate, ventilatory control instability (loop gain), and arousal threshold. DESIGN: Non-randomized single arm observational study. SETTING: Sleep laboratory. PATIENTS/PARTICIPANTS: 20 (15M, 5F) continuous positive airway pressure (CPAP)-treated severe OSA patients. INTERVENTIONS: Supine vs. lateral position. MEASUREMENTS: CPAP dial-downs performed during sleep to measure: (i) Veupnea: asleep ventilatory requirement, (ii) passive V0: ventilation off CPAP when airway dilator muscles are quiescent, (iii) Varousal: ventilation at which respiratory arousals occur, (iv) active V0: ventilation off CPAP when airway dilator muscles are activated during sleep, (v) loop gain: the ratio of the ventilatory drive response to a disturbance in ventilation, (vi) arousal threshold: level of ventilatory drive which leads to arousal, (vii) upper airway gain (UAG): ability of airway muscles to restore ventilation in response to increases in ventilatory drive, and (viii) pharyngeal critical closing pressure (Pcrit). Awake functional residual capacity (FRC) was also recorded. RESULTS: Lateral positioning significantly increased passive V0 (0.33 ± 0.76L/min vs. 3.56 ± 2.94L/min, P < 0.001), active V0 (1.10 ± 1.97L/min vs. 4.71 ± 3.08L/min, P < 0.001), and FRC (1.31 ± 0.56 L vs. 1.42 ± 0.62 L, P = 0.046), and significantly decreased Pcrit (2.02 ± 2.55 cm H2O vs. -1.92 ± 3.87 cm H2O, P < 0.001). Loop gain, arousal threshold, Varousal, and UAG were not significantly altered. CONCLUSIONS: Lateral positioning significantly improves passive airway anatomy/collapsibility (passive V0, pharyngeal critical closing pressure), the ability of the airway to stiffen and dilate (active V0), and the awake functional residual capacity without improving loop gain or arousal threshold.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.4992

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 118

Metadata

Authors
Joosten, S. A., Edwards, B. A., Wellman, A., Turton, A., Skuza, E. M., Berger, P. J., & Hamilton, G. S.
Venue
Sleep
Published
2015-09-01
Volume
38
Issue
9
Pages
1469-1478
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W167843604
Cited by
118
References
9
FWCI
6.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.