CoChat

A Portable Automated Assessment Tool for Sleep Apnea Using a Combined Holter-Oximeter

Open access
· 2008 · Sleep
Cited by 64

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: Resource limitations have raised interest in portable monitoring systems that can be used by specialist sleep physicians as part of an overall strategy to improve access to the diagnosis of sleep apnea. This study validates a combined electrocardiogram and oximetry recorder (Holter-oximeter) against simultaneous polysomnography for detection of sleep apnea. DESIGN: Prospective study. SETTING: A dedicated sleep disorders unit. PARTICIPANTS: 59 adults presenting for evaluation of suspected sleep apnea. INTERVENTIONS: NA. MEASUREMENTS AND RESULTS: An automated algorithm previously developed for sleep apnea detection was applied to the electrocardiogram and oximetry measurements. The algorithm provides (a) epoch-by-epoch estimates of apnea occurrence and (b) estimates of overall per-subject AHI. Using separate thresholds of AHI > or =15 and AHI <5 for defining clinically significant and insignificant sleep apnea, sensitivity, specificity, and likelihood ratios, conditional on positive or negative (but not indeterminate) test results were used to assess agreement between the proposed system and polysomnography. Sensitivity of 95.8% and specificity of 100% was achieved. Positive and negative likelihood ratios were >20 and 0.04 respectively, with 16.7% of subjects having intermediate test results (AHI 5-14/h). Regardless ofAHI, 85.3% of respiratory events were correctly annotated on an epoch-by-epoch basis. AHI underestimation bias was 0.9/h, and the antilogs of log-transformed limits of agreement were 0.3 and 2.7. Correlation between estimated and reference AHI was 0.95 (P <0.001). CONCLUSION: Combined Holter-oximeter monitoring compares well with polysomnography for identifying sleep apnea in an attended setting and is potentially suitable for home-based automated assessment of sleep apnea in a population suspected of having sleep apnea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep/31.10.1432

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 64

Metadata

Venue
Sleep
Published
2008-10-01
Volume
31
Issue
10
Pages
1432-9
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W1537508283
Cited by
64
References
8
FWCI
2.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Portable Automated Assessment Tool for Sleep Apnea Using a Combined Holter-Oximeter. https://app.cochat.ai/papers/10.5665/sleep/31.10.1432
The paper
A Portable Automated Assessment Tool for Sleep Apnea Using a Combined Holter-Oximeter. (2008). Sleep. https://doi.org/10.5665/sleep/31.10.1432

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.