CoChat

Heart rate variability in physically active individuals: reliability and gender characteristics.

Open access
Takshita Sookan, Andrew J. McKune · 2012 · PubMed
Cited by 72

The DOI matches its OpenAlex record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate the reliability of short-term recordings (five minutes) of heart rate variability (HRV) and the association between HRV and gender. METHODS: HRV time- and frequency-domain parameters were calculated in 44 physically active students (21 males and 23 females) over four consecutive days. A Suunto t6 heart rate monitor was used to obtain inter-beat intervals (IBIs) that were then transferred to Kubios HRV analysis software. The relative reliability [intra-class correlation (ICC)] and absolute reliability, [typical error of measurement (TEM) and typical error of measurement as a percentage (TEM%)] of the HRV parameters were then calculated for day 2 versus day 3 and day 3 versus day 4, with day 1 being a familiarisation day. The following HRV parameters were calculated: (1) time domain: resting heart rate (RHR), R-R intervals (IBI), standard deviation of normal-to-normal intervals (SDNN), root mean square differences of the standard deviation (RMSSD), percentage of beats that changed more than 50 ms from the previous beat (pNN50); and (2) frequency domain: low-frequency normalised units (LFnu), high-frequency normalised units (HFnu), low-frequency to high-frequency ratio in normalised units (LF/HFnu). An analysis of variance (ANOVA) with Tukey post-hoc testing was performed to compare HRV parameters in males and females. Significance was set at p ≤ 0.05. RESULTS: The ICCs for both relationship 1 and 2 indicated primarily good to excellent (> 0.8) relative reliability. The lowest value was found in the LF/HFnu ratio (ICC = 0.36) for males. Absolute reliability was low with TEM% greater than 10% for all HRV parameters, except IBIs. Females demonstrated better relative (higher ICCs) and absolute reliability (lower TEM and TEM% ) compared to males for the frequency domain. The relative and absolute reliability for the time domains were similar except for SDNN where the absolute reliability was higher in males. ANOVA illustrated significant gender differences for the LF/HFnu ratio (41% higher in males, p = 0.003), HFnu (12% higher in females, p = 0.02) and IBI (21% higher in females, p < 0.0001). CONCLUSIONS: Short-term recordings of HRV over three consecutive days demonstrated a high relative reliability. However, a low absolute reliability indicated large day-to-day random variation in HRV, which would make the detection of intervention effects using HRV difficult in individual participants. Females were shown to have a higher parasympathetic modulation of HRV, which may indicate an underlying cardioprotective mechanism in females compared to males.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.5830/cvja-2011.108

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 72

Metadata

Authors
Sookan, T., & McKune, A. J.
Venue
PubMed
Publisher
National Institutes of Health
Published
2012-03-01
Volume
23
Issue
2
Pages
67-72
OpenAlex
W1598058125
Cited by
72
References
4
FWCI
3.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart rate variability in physically active individuals: reliability and gender characteristics. https://app.cochat.ai/papers/10.5830/cvja-2011.108
The paper
Sookan, T., & McKune, A. J. (2012). Heart rate variability in physically active individuals: reliability and gender characteristics. PubMed. https://doi.org/10.5830/cvja-2011.108

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.