Effects of pH on Glucose Measurements With Handheld Glucose Meters and a Portable Glucose Analyzer for Point-of-Care Testing
The DOI matches its Crossref record.
Abstract
Objectives. —To determine pH effects on glucose measurements obtained with the latest generation of glucose devices, to quantitate changes in glucose measurements obtained over a wide pH range, and to assess the potential clinical risks of pH effects with use of point-of-care glucose testing. Design. —Paired differences of glucose measurements between pH-altered and parallel control samples with target pH 7.40 were calculated. Setting. —A pH range of 6.94 to 7.84 was used to evaluate pH effects on glucose measurements in vitro with 6 handheld glucose meters and a portable glucose analyzer at both normal, 4.81 mmol/L (86.6 mg/dL), and high, 11.16 mmol/L (201 mg/dL), glucose levels. Main Outcome Measures. —Glucose measurements obtained from test samples and control samples were compared by calculating paired differences, which were plotted against pH to show pH effects on glucose meter measurements. Results. —At the normal glucose level, different pH levels did not interfere significantly with glucose measurements. At the high glucose level, a trend whereby low pH decreased and high pH increased glucose measurements was observed on the Precision G and the Precision QID glucose meters. Conclusion. —Because of potential risk in diabetic patients with ketoacidosis and in other patients with acid-base disorders, we recommend that clinicians choose glucose devices carefully and interpret the measurements cautiously when point-of-care glucose testing is performed in critically ill patients with acidemia, alkalemia, or changing acid-base status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reliability of point-of-care testing for glucose measurement in critically ill adults*
Kanji, S., Buffie, J., Hutton, B., Bunting, P. S., Singh, A., McDonald, K., Fergusson, D., McIntyre, L. A., & Hebert, P. C. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000189939.10881.60 · Cited by 395
Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management
Dungan, K., Chapman, J., Braithwaite, S. S., & Buse, J. (2007) · Diabetes Care · doi:10.2337/dc06-1679 · Cited by 292
The Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144
Continuous Glucose Monitor Interference With Commonly Prescribed Medications: A Pilot Study
Basu, A., Slama, M. Q., Nicholson, W. T., Langman, L., Peyser, T., Carter, R., & Basu, R. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817697329 · Cited by 77
Allardet-Servent, J., Lebsir, M., Dubroca, C., Fabrigoule, M., Jordana, S., Signouret, T., Castanier, M., Thomas, G., Soundaravelou, R., Lepidi, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169593 · Cited by 64
Metadata
- Authors
- Tang, Z., Du, X., Louie, R. F., & Kost, G. J.
- Venue
- Archives of Pathology & Laboratory Medicine
- Published
- 2000-04
- Volume
- 124
- Issue
- 4
- Pages
- 577-582
- ISSN
- 0003-9985 (ISSN-L)
- 1543-2165
- OpenAlex
- W1929144650
- Cited by
- 92
- References
- 0
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of pH on Glucose Measurements With Handheld Glucose Meters and a Portable Glucose Analyzer for Point-of-Care Testing. https://app.cochat.ai/papers/10.5858/2000-124-0577-eopogm
- The paper
- Tang, Z., Du, X., Louie, R. F., & Kost, G. J. (2000). Effects of pH on Glucose Measurements With Handheld Glucose Meters and a Portable Glucose Analyzer for Point-of-Care Testing. Archives of Pathology & Laboratory Medicine. https://doi.org/10.5858/2000-124-0577-eopogm
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.