CoChat

Ovarian Frozen Section Diagnosis: Use of Whole-Slide Imaging Shows Excellent Correlation Between Virtual Slide and Original Interpretations in a Large Series of Cases

Fallon, Margaret A., Wilbur, David C., Prasad, Manju · 2010 · Archives of Pathology & Laboratory Medicine
Cited by 78

The DOI matches its Crossref record.

Abstract

Context.—Whole-slide images (WSI) are a tool for remote interpretation, archiving, and teaching. Ovarian frozen sections (FS) are common and hence determination of the operating characteristics of the interpretation of these specimens using WSI is important. Objectives.—To test the reproducibility and accuracy of ovarian FS interpretation using WSI, as compared with routine analog interpretation, to understand the technology limits and unique interpretive pitfalls. Design.—A sequential series of ovarian FS slides, representative of routine practice, were converted to WSI. Whole-slide images were examined by 2 pathologists, masked to all prior results. Correlation characteristics among the WSI, the original, and the final interpretations were analyzed. Results.—A total of 52 cases, consisting of 71 FS slides, were included; 34 cases (65%) were benign, and 18 cases (35%) were malignant, borderline, and of uncertain potential (9 [17%], 7 [13%], and 2 [4%] of 52 cases, respectively). The correlation between WSI and FS interpretations was 96% (50 of 52) for each pathologist for benign versus malignant, borderline, and uncertain entities. Each pathologist undercalled 2 borderline malignant cases (4%) as benign cysts on WSI. There were no overcalls of benign cases. Specific issues within the benign and malignant groups involved endometriosis versus hemorrhagic corpora lutea, and granulosa cell tumor versus carcinoma, respectively. Conclusions.—The correlation between original FS and WSI interpretations was very high. The few discordant cases represent recognized differential diagnostic issues. Ability to examine gross pathology and real-time consultation with surgeons might be expected to improve performance. Ovarian FS diagnosis by WSI is accurate and reproducible, and thus, remote interpretation, teaching, and digital archiving of ovarian FS specimens by this method can be reliable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5858/2009-0320-oa.1

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 78

Metadata

Authors
Fallon, M. A., Wilbur, D. C., & Prasad, M.
Venue
Archives of Pathology & Laboratory Medicine
Published
2010-07-01
Volume
134
Issue
7
Pages
1020-1023
ISSN
  • 0003-9985 (ISSN-L)
  • 1543-2165
OpenAlex
W1944644519
Cited by
78
References
0
FWCI
7.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ovarian Frozen Section Diagnosis: Use of Whole-Slide Imaging Shows Excellent Correlation Between Virtual Slide and Original Interpretations in a Large Series of Cases. https://app.cochat.ai/papers/10.5858/2009-0320-oa.1
The paper
Fallon, M. A., Wilbur, D. C., & Prasad, M. (2010). Ovarian Frozen Section Diagnosis: Use of Whole-Slide Imaging Shows Excellent Correlation Between Virtual Slide and Original Interpretations in a Large Series of Cases. Archives of Pathology & Laboratory Medicine. https://doi.org/10.5858/2009-0320-oa.1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.