Cited by 11Systemic Lupus Erythematosus ResearchBlood Coagulation and Thrombosis MechanismsHeparin-Induced Thrombocytopenia and Thrombosis

Direct Thrombin Inhibitors and Factor Xa Inhibitors Can Influence the Diluted Prothrombin Time Used as the Initial Screen for Lupus Anticoagulant

Olah, Zsolt, Szarvas, Mariann, Bereczky, Zsuzsanna, Kerenyi, Adrienne, Kappelmayer, Janos, Boda, Zoltan·2013·Archives of Pathology and Laboratory Medicine

Abstract

Context Lupus anticoagulant (LA) is a heterogeneous group of antiphospholipid antibodies. Among others, diluted prothrombin time (dPT) is a sensitive screening test for LA; however, the interpretation of LA tests is difficult in patients treated with anticoagulants. The effect of different types of anticoagulants on the result of LA tests, particularly on dPT, has not been studied extensively. Objective To determine whether the direct thrombin inhibitors lepirudin and argatroban and the predominantly factor Xa inhibitors enoxaparin, danaparoid, and fondaparinux could interfere with LA screening based on dPT. Design Each drug was added to normal and LA-positive plasmas in clinically relevant concentrations. Each sample was tested for dPT. Samples with factor Xa inhibitors were investigated before and after addition of heparinase. Mixing and confirmatory tests for LA were not performed. Results In the presence of lepirudin or argatroban, dPT increased notably and the dPT ratio exceeded the cutoff value even at subtherapeutic concentrations resulting in false positivity. With increasing factor Xa inhibitor concentrations, a linear increase of dPT ratios and false-positive results were also demonstrated. Although heparinase could almost completely neutralize the anti-Xa effect of all investigated factor Xa inhibitors, dPT ratio returned to the basal level only in case of enoxaparin. Conclusions Here we provide evidence that both the direct thrombin and indirect factor Xa inhibito…

Integrity signals

Registry

Crossref · 10.5858/arpa.2012-0236-oa

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • False positives have been described for aPTT and dRVVT even when utilizing heparin neutralizers.

    “False positives have been described for aPTT and dRVVT even when utilizing neutralizers [68,69,70].”

    From Lupus Anticoagulant Detection under the Magnifying Glass (2023) · cites this paper as [68]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Olah, Z., Szarvas, M., Bereczky, Z., Kerenyi, A., Kappelmayer, J., & Boda, Z.
Affiliations
  • From the 2nd Department of Medicine (Drs Olah and Boda and Miss Szarvas), the Clinical Research Center (Dr Bereczky), and the Department of Laboratory Medicine (Drs Kerenyi and Kappelmayer), University of Debrecen, Debrecen, Hungary.
  • University of Debrecen (HU)
Venue
Archives of Pathology and Laboratory Medicine
Published
2013-07
Volume
137
Issue
7
Pages
967-973
ISSN
  • 0003-9985 (ISSN-L)
  • 1543-2165
OpenAlex
W2006990092
Cited by
11
References
4
Citations by year
2024: 1 · 2023: 2 · 2022: 1 · 2021: 1 · 2019: 1 · 2018: 1 · 2016: 3 · 2015: 1
FWCI
1.09
Type
journal article
Language
en
Open access
closed
Locations
  • Archives of Pathology & Laboratory Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • University of Debrecen Electronic Archive (University of Debrecen) (submittedVersion)
Topics
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Health Sciences › Medicine › Surgery › Heparin-Induced Thrombocytopenia and Thrombosis
Keywords
lupus anticoagulant, direct thrombin inhibitors, factor Xa inhibitors, lepirudin, argatroban, enoxaparin, danaparoid, fondaparinux, false positives, anticoagulant interference, heparinase, antiphospholipid antibodies
MeSH terms
Fondaparinux, Anticoagulants, Antithrombins, Arginine, Chondroitin Sulfates, Dermatan Sulfate, False Positive Reactions, Heparan Sulfate, Hirudins, Humans, Mass Screening, Pipecolic Acids, Polysaccharides, Prothrombin Time, Recombinant Proteins, Sulfonamides, Thrombin, Lupus Coagulation Inhibitor, Enoxaparin, Factor Xa Inhibitors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review