CoChat

Validating Whole Slide Imaging Systems for Diagnostic Purposes in Pathology

Open access
Evans, Andrew J, Brown, Richard W., Bui, Marilyn M., Chlipala, Elizabeth A., Lacchetti, Christina, Milner, Danny A., Pantanowitz, Liron, Parwani, Anil V., Reid, Kearin, Riben, Michael W., Reuter, Victor E., Stephens, Lisa, Stewart, Rachel L., Thomas, Nicole E. · 2022 · Archives of Pathology & Laboratory Medicine
Cited by 209

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Context.—: The original guideline, “Validating Whole Slide Imaging for Diagnostic Purposes in Pathology,” was published in 2013 and included 12 guideline statements. The College of American Pathologists convened an expert panel to update the guideline following standards established by the National Academies of Medicine for developing trustworthy clinical practice guidelines. Objective.—: To assess evidence published since the release of the original guideline and provide updated recommendations for validating whole slide imaging (WSI) systems used for diagnostic purposes. Design.—: An expert panel performed a systematic review of the literature. Frozen sections, anatomic pathology specimens (biopsies, curettings, and resections), and hematopathology cases were included. Cytology cases were excluded. Using the Grading of Recommendations Assessment, Development, and Evaluation approach, the panel reassessed and updated the original guideline recommendations. Results.—: Three strong recommendations and 9 good practice statements are offered to assist laboratories with validating WSI digital pathology systems. Conclusions.—: Systematic review of literature following release of the 2013 guideline reaffirms the use of a validation set of at least 60 cases, establishing intraobserver diagnostic concordance between WSI and glass slides and the use of a 2-week washout period between modalities. Although all discordances between WSI and glass slide diagnoses discovered during validation need to be reconciled, laboratories should be particularly concerned if their overall WSI–glass slide concordance is less than 95%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5858/arpa.2020-0723-cp

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Metadata

Authors
Evans, A. J., Brown, R. W., Bui, M. M., Chlipala, E. A., Lacchetti, C., Milner, D. A., Pantanowitz, L., Parwani, A. V., Reid, K., Riben, M. W., Reuter, V. E., Stephens, L., Stewart, R. L., & Thomas, N. E.
Venue
Archives of Pathology & Laboratory Medicine
Published
2021-05-18
Volume
146
Issue
4
Pages
440-450
ISSN
  • 0003-9985 (ISSN-L)
  • 1543-2165
OpenAlex
W3160847342
Cited by
209
References
6
FWCI
9.26
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validating Whole Slide Imaging Systems for Diagnostic Purposes in Pathology. https://app.cochat.ai/papers/10.5858/arpa.2020-0723-cp
The paper
Evans, A. J., Brown, R. W., Bui, M. M., Chlipala, E. A., Lacchetti, C., Milner, D. A., Pantanowitz, L., Parwani, A. V., Reid, K., Riben, M. W., Reuter, V. E., Stephens, L., Stewart, R. L., & Thomas, N. E. (2022). Validating Whole Slide Imaging Systems for Diagnostic Purposes in Pathology. Archives of Pathology & Laboratory Medicine. https://doi.org/10.5858/arpa.2020-0723-cp

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.