Survey of Diabetes Technology in the Pediatric Inpatient Setting
Open accessAbstract
OBJECTIVE: Advances in diabetes technology have led to increasing use of insulin pumps and continuous glucose monitors (CGMs) to improve the quality of life for children with diabetes. The objective of this study was to assess the percentage of hospitals that had policies regarding the use of diabetes technology in the pediatric inpatient setting and assess the content of policies to identify specific areas for improvement. METHODS: A diabetes technology survey was developed by a multidisciplinary research team, consisting of 3 domains including CGM use/policies, insulin pump use/policies, and demographics. It was distributed to the pharmacist membership of the Pediatric Pharmacy Association in August 2022. Descriptive statistics were conducted to describe current practices/policies. RESULTS: Seventeen of the 31 responding hospitals (55%) allowed CGM use in the pediatric inpatient setting with 77% (n = 13) having written policies. Primary barriers to use included lack of policy (n = 11, 79%), knowledgeable staff (n = 10, 71%), and electronic health record (EHR) integration (n = 6, 43%). More than half reported not using CGM alarms for high and low blood sugar levels (n = 10, 59%). More hospitals allowed insulin pump use (n = 29, 94%) with 97% (n = 28) reporting written policies. Less than half had specific policies for suspected pump site failure (n = 13, 46%). Only 60% reported that nurses verify insulin pump doses given. CONCLUSION: This study demonstrates there is room to improve both the existence and content of policies related to CGM and insulin pump use in hospitals.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In a recent survey, less than half the hospitals had these policies in place.
“In a recent survey, less than half the hospitals had these policies in place (61).”
From 16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2026 (2026) · cites this paper as [61]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
7. Diabetes Technology: <i>Standards of Care in Diabetes</i> — <i>2023</i>
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301 · see citing works
Continuous glucose monitoring: A review of the evidence in type 1 and 2 diabetes mellitus
Lin, R., Brown, F., James, S., Jones, J., & Ekinci, E. (2021) · Diabetic Medicine · doi:10.1111/dme.14528 · Cited by 197 · see citing works
Galindo, R. J., Aleppo, G., Klonoff, D. C., Spanakis, E. K., Agarwal, S., Vellanki, P., Olson, D. E., Umpierrez, G. E., Davis, G. M., & Pasquel, F. J. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820932903 · Cited by 155 · see citing works
Accuracy of continuous glucose monitors for inpatient diabetes management
Wright, J. J., Williams, A. J., Friedman, S. B., Weaver, R. G., Williams, J. M., Hodge, E., Fowler, M., & Bao, S. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221076562 · Cited by 49 · see citing works
Flagged first, then by citations
Research works printed but not linked: 16
- Lawrence JM, Divers J, Isom S, et al. Trends in prevalence of type 1 and type 2 diabetes in children and adolescents in the US, 2001-2017. JAMA. 2021;326(8):717-727.
- Jeyam A, Gibb FW, McKnight JA, et al. Marked improvements in glycaemic outcomes following insulin pump therapy initiation in people with type 1 diabetes: a nationwide observational study in Scotland. Diabetologia. 2021;64(6):1320-1331.
- Davis GM, Spanakis EK, Migdal AL, et al. Accuracy of Dexcom G6 continuous glucose monitoring in non- critically ill hospitalized patients with diabetes. Diabetes Care. 2021;44(7):1641-1646.
- Murray-Bachmann R, Leung TM, Myers AK, et al. Reliability of continuous glucose monitoring system in the inpatient setting. J Clin Transl Endocrinol. 2021;25:100262.
- Li Y, Cao B, Chen Q, et al. Application of the FreeStyle®Libre Glucose Monitoring System in type 1 diabetes mellitus patients aged 1-4 years. Pediatr Diabetes. 2022;23(5): 604-610.
- Espinoza J, Xu NY, Nguyen KT, Klonoff DC. The need for data standards and implementation policies to integrate CGM data into the electronic health record. J Diabetes Sci Technol. 2023;17(2):495-502.
- Espinoza JC, Yeung AM, Huang J, et al. The need for data standards and implementation policies to integrate insu- lin delivery data into the electronic health record [pub- lished online ahead of print May 26, 2023]. J Diabetes Sci Technol. 10.1177/19322968231178549 · DOI
- Halstrom A, Moledina I, Peragallo-Dittko V, et al. Continuous subcutaneous insulin infusions vs. mul- tiple daily injections of insulin in hospitalized patients: glycemic trends in the first 24 hours of admission. J Diabetes Sci Technol. 2022;16(3):683-688.
- Coffer S, Schlichting L, Cunningham JM. Insulin pump treatment for the hospitalized patient. JAMA Intern Med. 2021;181(5):685-686.
- Atif Z, Halstrom A, Peragallo-Dittko V, Klek SP. Efficacy of hybrid closed-loop insulin delivery system in a hospital setting: a case series. AACE Clin Case Rep. 2021;7(3):184-188.
- Yeh T, Yeung M, Mendelsohn Curanaj FA. Managing patients with insulin pumps and continuous glucose monitors in the hospital: to wear or not to wear. Curr Diab Rep. 2021;21(2):7.
- Umpierrez GE, Klonoff DC. Diabetes technology update: use of insulin pumps and continuous glucose monitoring in the hospital. Diabetes Care. 2018;41(8):1579-1589.
- Wallia A, Umpierrez GE, Rushakoff RJ, et al. Consen- sus statement on inpatient use of continuous glu- cose monitoring. J Diabetes Sci Technol. 2017;11(5): 1036-1044.
- Boughton CK, Hovorka R. New closed-loop insulin sys- tems. Diabetologia. 2021;64(5):1007-1015.
- Evans K. Diabetic ketoacidosis: update on management. Clin Med. 2019;19(5):396-398.
- Ryan D, Burke SD, Litchman ML, et al. Competencies for diabetes care and education specialists. Diabetes Educ. 2020;46(4):384-397.
Cited by
Sorted by citations
16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2026
American Diabetes Association Professional Practice Committee for Diabetes*, Bajaj, M., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Briggs Early, K., ChallaSivaKanaka, S., et al. (2026) · Diabetes Care · doi:10.2337/dc26-s016 · Cited by 80 · see citing works
- Authors
- Hamilton, A. B., Rajagopal, N., Ngo, C., Hendrix-Dicken, A. D., Mercer, S., & Condren, M.
- Affiliations
- University of Tulsa (US)
- University of Oklahoma (US)
- Department of Pediatrics (ADH-D, SM, MC), OU-TU School of Community Medicine, Tulsa, OK
- Venue
- The Journal of Pediatric Pharmacology and Therapeutics
- Publisher
- The Pediatric Pharmacy Association
- Published
- 2025-02
- Volume
- 30
- Issue
- 1
- Pages
- 123-128
- ISSN
- 1551-6776 (ISSN-L)
- 2331-348X
- PMC
- PMC11809535
- OpenAlex
- W4407426884
- Cited by
- 3
- References
- 4
- Citations by year
- 2026: 3
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Pediatric Pharmacology and Therapeutics (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Oklahoma
- University of Oklahoma Health Sciences Center
- National Institute of Child Health and Human Development
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (U54HD113173)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
- Keywords
- diabetes technology, continuous glucose monitoring, insulin pump, pediatric inpatient care, hospital policy, pediatric diabetes, electronic health record integration, technology adoption barriers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review