Guide to Industrial Control Systems (ICS) Security
Open accessThe DOI matches its Crossref record; 75 of the 84 references it cites were found in a registry or an index.
Abstract
This publication has been developed by NIST to further its statutory responsibilities under the Federal Information Security Modernization Act (FISMA) of 2014, 44 U.S.C. § 3541 et seq., Public Law (P.L.) 113-283.NIST is responsible for developing information security standards and guidelines, including minimum requirements for federal information systems, but such standards and guidelines shall not apply to national security systems without the express approval of appropriate federal officials exercising policy authority over such systems.This guideline is consistent with the requirements of the Office of Management and Budget (OMB) Circular A-130, Section 8b(3), Securing Agency Information Systems, as analyzed in Circular A-130, Appendix IV: Analysis of Key Sections. Supplemental information is provided in Circular A-130, Appendix III, Security of Federal Automated Information Resources.Nothing in this publication should be taken to contradict the standards and guidelines made mandatory and binding on federal agencies by the Secretary of Commerce under statutory authority.Nor should these guidelines be interpreted as altering or superseding the existing authorities of the Secretary of Commerce, Director of the OMB, or any other federal official.This publication may be used by nongovernmental organizations on a voluntary basis and is not subject to copyright in the United States.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The increased connectivity and automation capabilities of Industry 4.0 cyber-physical production systems (CPPS) create significant cyber-security vulnerabilities in supervisory control and data acquisition (SCADA) environments if robust protections are not properly implemented.”
From Seamless Industry 4.0 Integration: A Multilayered Cyber-Security Framework for Resilient SCADA Deployments in CPPS (2023) · cites this paper as [4]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This definition essentially eliminates any need for comparison of SCADA system with any other physical or cyberphysical and IoT or IIoT devices or concepts as any IT system performing these functions is a SCADA system in some physical form regardless of its design, structure or architecture.”
From SCADA Systems With Focus on Continuous Manufacturing and Steel Industry: A Survey on Architectures, Standards, Challenges and Industry 5.0 (2022) · cites this paper as [86]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“This exposes manufacturers to substantial risks of cyberattacks that could manipulate, disrupt, or disable critical physical assets and processes related to their production lines and facilities.”
From Seamless Industry 4.0 Integration: A Multilayered Cyber-Security Framework for Resilient SCADA Deployments in CPPS (2023) · cites this paper as [4]
The cited source says what the claim attributes to it.
In the citing paper
“SCADA connectivity to corporate environments also introduces cyber risks if not protected.”
From Seamless Industry 4.0 Integration: A Multilayered Cyber-Security Framework for Resilient SCADA Deployments in CPPS (2023) · cites this paper as [4]
The cited source says what the claim attributes to it.
In the citing paper
“Accordingly, there are multiple security recommendations and guidelines from relevant institutions such as the National Institute of Standards and Technology (NIST) [86] and U.S. Department of Homeland Security [187] providing incident response models.”
From SCADA Systems With Focus on Continuous Manufacturing and Steel Industry: A Survey on Architectures, Standards, Challenges and Industry 5.0 (2022) · cites this paper as [86]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Guidelines for Media Sanitization
Kissel, R., Regenscheid, A., Scholl, M., & Stine, K. (2014) · doi:10.6028/nist.sp.800-88r1 · Cited by 102
RetractedIdentifying, understanding, and analyzing critical infrastructure interdependencies
(2001) · IEEE Control Systems · doi:10.1109/37.969131 · Cited by 2,851 · cited 2×
“critical infrastructure is often referred to as a “system of systems” because of the interdependencies that exist between its various industrial sectors as well as interconnections between business partners [8] [9].”
BackgroundTödtling, F., & Trippl, M. (2005) · Research Policy · doi:10.1016/j.respol.2005.01.018 · Cited by 2,571
Guide to Intrusion Detection and Prevention Systems (IDPS)
Scarfone, K. A., & Mell, P. M. (2007) · doi:10.6028/nist.sp.800-94 · Cited by 1,279
Hiatt, J. M. (2003) · Cited by 664
Guide to Integrating Forensic Techniques into Incident Response
Kent, K., Chevalier, S., Grance, T., & Dang, H. (2006) · doi:10.6028/nist.sp.800-86 · Cited by 590
Cichonski, P., Millar, T., Grance, T., & Scarfone, K. (2012) · doi:10.6028/nist.sp.800-61r2 · Cited by 485
Security and Privacy Controls for Federal Information Systems and Organizations
Joint Task Force Transformation Initiative (2013) · doi:10.6028/nist.sp.800-53r4 · Cited by 470
Erickson, K. T., & Hedrick, J. L. (1999) · Wiley eBooks · Cited by 438
Framework for Improving Critical Infrastructure Cybersecurity, Version 1.1
National Institute of Standards and Technology (2018) · doi:10.6028/nist.cswp.04162018 · Cited by 386
Research works printed but not linked: 3
- Weiss, Joseph, "Current Status of Cybersecurity of Control Systems," Presentation to Georgia Tech Protective Relay Conference, May 8, 2003.
- Symantec Corporation, "Symantec Expands SCADA Protection for Electric Utilities," [press release], September 14, 2005, http://www.symantec.com/about/news/release/article.jsp?prid=20050914_01 [accessed 4/16/15].
- Scarfone, Karen, et al., NIST SP 800-48 Revision 1, Guide to Securing Legacy IEEE 802.11
Cited by
Items 301–400 of 1,003
You Snooze, You Lose: Measuring {PLC} Cycle Times under Attacks
Niedermaier, M., Malchow, J.-O., Fischer, F., Marzin, D., Merli, D., Röth, V., & von Bodisco, A. (2018) · USENIX Security Symposium · Cited by 25
An Open Framework for Deploying Experimental SCADA Testbed Networks
Maynard, P., McLaughlin, K., & Sezer, S. (2018) · Electronic workshops in computing · doi:10.14236/ewic/ics2018.11 · Cited by 32
“NIST SP 800-82r2, Stouffer et al. (2015) recommends an ICS security architecture, which includes network segmentation, boundary protection and the use of Demilitarised Zone (DMZ) for separation between enterprise network and SCADA network.”
Adapting big data standards, maturity models to smart grid distributed generation: critical review
Sundararajan, A., Hernandez, A. S., & Sarwat, A. I. (2020) · IET Smart Grid · doi:10.1049/iet-stg.2019.0298 · Cited by 25
The Xilinx Isolation Design Flow for Fault-Tolerant Systems
Corbett, J. D. (2013) · Cited by 25
Control Baselines for Information Systems and Organizations
JOINT TASK FORCE (2020) · doi:10.6028/nist.sp.800-53b · Cited by 42
Considerations for Managing Internet of Things (IoT) Cybersecurity and Privacy RisksPreprint
Scarfone, K. A. (2018) · doi:10.6028/nist.ir.8228-draft · Cited by 27
SICARD, F., ZAMAI, É., & FLAUS, J.-M. (2019) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2019.03.020 · Cited by 25
Agentless Approach for Security Information and Event Management in Industrial IoT
Zahid, H., Hina, S., Hayat, M. F., & Shah, G. A. (2023) · Electronics · doi:10.3390/electronics12081831 · Cited by 24
Sensor technologies for quality control in engineered tissue manufacturing
McCorry, M. C., Reardon, K. F., Black, M. R., Williams, C., Babakhanova, G., Halpern, J. M., Sarkar, S., Swami, N. S., Mirica, K. A., Boermeester, S., et al. (2022) · Biofabrication · doi:10.1088/1758-5090/ac94a1 · Cited by 27
Organisational Cyber Resilience: Management Perspectives
Bagheri, S., Ridley, G., & Williams, B. R. (2023) · AJIS. Australasian journal of information systems/AJIS. Australian journal of information systems/Australian journal of information systems · doi:10.3127/ajis.v27i0.4183 · Cited by 24
Zhang, D., Wang, M., Bu, Y., Yu, J., & Yang, L. (2024) · Computers & Security · doi:10.1016/j.cose.2024.104210 · Cited by 35
Formal Analysis of Security Properties on the OPC-UA SCADA Protocol
Puys, M., Potet, M.-L., & Lafourcade, P. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-45477-1_6 · Cited by 35
Resilient Control for Networked Control Systems Subject to Cyber/Physical Attacks
Rhouma, T., Chabir, K., & Abdelkrim, M. N. (2017) · Machine Intelligence Research · doi:10.1007/s11633-017-1059-x · Cited by 25
“Such systems are often considered as large scale distributed physical processes but not necessarily always large and can be monitored and controlled by using a supervisory control and data acquisition (SCADA) software which can be critical to system operation [3] in various infrastructures.”
BackgroundToward Interoperable Self-Sovereign Identities
Yildiz, H., Küpper, A., Thatmann, D., Göndör, S., & Herbke, P. (2023) · IEEE Access · doi:10.1109/access.2023.3313723 · Cited by 41
“Authentication of a user is the process of verifying a claimed identity, whereas authorization is granting access privileges [76].”
BackgroundIndustrial wireless: Problem space, success considerations, technologies, and future direction
Candell, R., & Kashef, M. (2017) · Resilience Week (RWS) · doi:10.1109/rweek.2017.8088661 · Cited by 23
“Guidance on selecting which controls are applicable to a specific risk level may be found in [18].”
BackgroundAttacking SCADA systems: A practical perspective
Rosa, L., Cruz, T., Simões, P., Monteiro, E., & Lev, L. (2017) · IFIP/IEEE International Symposium on Integrated Network Management (IM) · doi:10.23919/inm.2017.7987369 · Cited by 30
Bridging the Gap from Cyber Security to Resilience
Roege, P., Collier, Z. A., Chevardin, V., Chouinard, P., Florin, M., Lambert, J. H., Nielsen, K. M., Nogal, M., & Todorović, B. M. (2017) · NATO science for peace and security series. C, Environmental security · doi:10.1007/978-94-024-1123-2_14 · Cited by 29
Snapshotter: Lightweight intrusion detection and prevention system for industrial control systems
Jin, C., Valizadeh, S., & van Dijk, M. (2018) · IEEE International Conference on Industrial Cyber-Physical Systems (ICPS) · doi:10.1109/icphys.2018.8390813 · Cited by 27
“In this regard, being the “holy grail of cyberwar”, the National Institute of Standards and Technology (NIST) provides a detailed guidance document [1] for establishing secure ICS by identifying common threats and vulnerabilities in such systems, in addition to recommendations for security solutions and risk mitigatio…”
BackgroundMilošević, J., Umsonst, D., Sandberg, H., & Johansson, K. H. (2018) · European Control Conference (ECC) · doi:10.23919/ecc.2018.8550188 · Cited by 28
“The overall recommendation for improving the cyber-security of these systems is to implement the so called defense-in-depth strategies, which consist of several layers of security measures [9].”
BackgroundPeterson, J. N., Haney, M., & Borrelli, R. A. (2019) · Nuclear Engineering and Design · doi:10.1016/j.nucengdes.2019.02.025 · Cited by 58
False data injection attacks and the insider threat in smart systems
Gönen, S., Sayan, H. H., Yılmaz, E. N., Üstünsoy, F., & KARACAYILMAZ, G. (2020) · Computers & Security · doi:10.1016/j.cose.2020.101955 · Cited by 27
Automated and Secure Onboarding for System of Systems
Maksuti, S., Bicaku, A., Zsilak, M., Ivkić, I., Peceli, B., Singler, G., Kovács, K., Tauber, M., & Delsing, J. (2021) · IEEE Access · doi:10.1109/access.2021.3102280 · Cited by 27
“According to NIST SP 800-82, authorization is ‘‘the right or a permission that is granted to a system entity to access a system resource’’ [29].”
Towards trustworthy end-to-end communication in industry 4.0
Bicaku, A., Maksuti, S., Palkovits-Rauter, S., Tauber, M., Matischek, R., Schmittner, C., Μαντάς, Γ., Thron, M., & Delsing, J. (2017) · IEEE International Conference on Industrial Informatics (INDIN) · doi:10.1109/indin.2017.8104889 · Cited by 31
“Source: NIST SP 800-82 [18], IEC 62443-3[20]”
Enhancing integrity of modbus TCP through covert channels
Taylor, J. M., & Sharif, H. (2017) · International Conference on Signal Processing and Communication Systems · doi:10.1109/icspcs.2017.8270454 · Cited by 23
Industrial IoT cross‐layer forensic investigation
Rondeau, C. M., Temple, M. A., & Lopez, J. (2018) · Wiley Interdisciplinary Reviews Forensic Science · doi:10.1002/wfs2.1322 · Cited by 26
A model-driven development framework for developing sense-compute-control applications
Patel, P., Morin, B., & Chaudhary, S. (2014) · doi:10.1145/2593783.2593784 · Cited by 22
“For example, a building interacts with its residents and surrounding buildings in case of fire for safety and security of residents [2], offices adjust themselves automatically accordingly to user preferences while minimizing energy consumption [4], traffic signals control in-flow of vehicles according to the current…”
BackgroundA Model-Data Integrated Cyber Security Risk Assessment Method for Industrial Control Systems
Yuan, P., Huang, K., Tu, W., & Zhou, C. (2018) · IEEE Data Driven Control and Learning Systems Conference (DDCLS) · doi:10.1109/ddcls.2018.8516022 · Cited by 27
Cyber LOPA: An Integrated Approach for the Design of Dependable and Secure Cyber-Physical Systems
Tantawy, A., Abdelwahed, S., & Erradi, A. (2022) · IEEE Transactions on Reliability · doi:10.1109/tr.2022.3163652 · Cited by 27
“The CSTR process is controlled by the industrial control system shown in Figure 7, which follows NIST 800-82 standard with one firewall and a DeMilitariZed (DMZ) zone [13].”
MethodDevelopment of a concept for building a critical infrastructure facilities security system
Yevseiev, S., Melenti, Y., Войтко, О., Гребенюк, В. М., Корченко, А. О., Mykus, S. A., Мілов, О. В., Prokopenko, O., Сєвєрінов, О., & Chopenko, D. (2021) · Eastern-European Journal of Enterprise Technologies · doi:10.15587/1729-4061.2021.233533 · Cited by 33
“In particular, [2] discusses the security issues of industrial control systems, the solution of which involves considering unique performance, reliability and safety requirements.”
BackgroundOrojloo, H., & Azgomi, M. A. (2018) · Journal of Network and Systems Management · doi:10.1007/s10922-018-9449-0 · Cited by 24
“In an industrial control system, VPNs are the means of securing sensitive data.”
BackgroundInfluentialSecurity Development Lifecycle for Cyber-Physical Production Systems
Eckhart, M., Ekelhart, A., Lüder, A., Biffl, S., & Weippl, E. R. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927590 · Cited by 24
“Designing the security policies and procedures is not a separate activity, but rather closely intertwined with Security Risk Management [19].”
BackgroundMethodInfluentialSeverson, T. A., Croteau, B., Rodríguez-Seda, E. J., Kiriakidis, K., Robucci, R., & Patel, C. (2020) · Control Engineering Practice · doi:10.1016/j.conengprac.2020.104509 · Cited by 24
Cyber‐Physical System Resilience
Haque, M. A., Shetty, S. S., & Krishnappa, B. (2019) · Wiley eBooks · doi:10.1002/9781119552482.ch12 · Cited by 24
Nuruzzaman, M., & Rana, S. (2025) · doi:10.63125/pyd1x841 · Cited by 41
Detecting Data Integrity Attacks on Correlated Solar Farms Using Multi-layer Data Driven Algorithm
Lore, K. G., Shila, D. M., & Ren, L. (2018) · IEEE Conference on Communications and Network Security · doi:10.1109/cns.2018.8433159 · Cited by 23
“exposure, providing entry points for threat actors to disrupt grid operations [1]–[4].”
BackgroundPCaaD: Towards automated determination and exploitation of industrial systems
Green, B., Derbyshire, R., Krotofil, M., Knowles, W., Prince, D., & Suri, N. (2021) · Computers & Security · doi:10.1016/j.cose.2021.102424 · Cited by 28
“All other Field Site devices are not permitted to communicate outside of the Field Site network (managed by 1: Synchronization Byte perimeter firewalls, a baseline recognized practice to defend zone boundaries [8,60]).”
BackgroundInfluentialActive multiplicative cyberattack detection utilizing controller switching for process systems
Narasimhan, S., El‐Farra, N. H., & Ellis, M. J. (2022) · Journal of Process Control · doi:10.1016/j.jprocont.2022.05.014 · Cited by 21
Faking smart industry: exploring cyber-threat landscape deploying cloud-based honeypot
Rashid, S. M. Z. U., Haq, A., Hasan, S. T., Furhad, M. H., Ahmed, M., & Ullah, A. B. (2022) · Wireless Networks · doi:10.1007/s11276-022-03057-y · Cited by 21
A Multi-Model Proposal for Classification and Detection of DDoS Attacks on SCADA Systems
Söğüt, E., & Erdem, O. A. (2023) · Applied Sciences · doi:10.3390/app13105993 · Cited by 33
Secure Communications in Smart Grid: Networking and Protocols
McLaughlin, K., Friedberg, I., Kang, B., Maynard, P., Sezer, S., & McWilliams, G. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-802122-4.00005-5 · Cited by 29
Chen, Q., Abercrombie, R. K., & Sheldon, F. T. (2015) · Journal of Artificial Intelligence and Soft Computing Research · doi:10.1515/jaiscr-2015-0029 · Cited by 27
“Therefore, the first step to enhance security of SCADA systems is to mitigate risks of known threats and vulnerabilities by producing and implementing recommendations of security controls and alternative solutions periodically [27, 30, 31].”
BackgroundMethodAn experiment in using IMUNES and Conpot to emulate honeypot control networks
Kuman, S., Groš, S., & Mikuc, M. (2017) · International Convention on Information and Communication Technology, Electronics and Microelectronics · doi:10.23919/mipro.2017.7973617 · Cited by 21
Characterizing Background Noise in ICS Traffic Through a Set of Low Interaction Honeypots
Ferretti, P., Pogliani, M., & Zanero, S. (2019) · doi:10.1145/3338499.3357361 · Cited by 25
“On the field of defense, efforts concentrated on offering standardized security guidelines for ICS and SCADA systems [8, 18], suggesting network segmentation and firewalls.”
BackgroundA Host-based Intrusion Detection Model Based on OS Diversity for SCADA
Bulle, B. B., Santin, A. O., Viegas, E. K., & dos Santos, R. R. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9255062 · Cited by 27
“The security of SCADA systems must be performed through a wide range of security mechanisms, including firewalls, airgapped infrastructures, and Intrusion Detection Systems (IDS), used for the monitoring and detection of malicious activities in an environment [4].”
BackgroundAn integrated framework for control system simulation and regulatory compliance monitoring
Mahoney, W., & Gandhi, R. A. (2011) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2011.03.002 · Cited by 21
Outage of Periodic Downlink Wireless Networks With Hard Deadlines
Jurdi, R., Khosravirad, S. R., Viswanathan, H., Andrews, J. G., & Heath, R. W. (2018) · IEEE Transactions on Communications · doi:10.1109/tcomm.2018.2879934 · Cited by 21
Wireless user requirements for the factory workcell
Montgomery, K. R., Candell, R., Liu, Y., & Hany, M. (2021) · doi:10.6028/nist.ams.300-8r1/upd · Cited by 21
“4 2.8 Security .................................................................................................................................... 4 2.9 System Availability ................................................................................................................. 5”
BackgroundInfluentialIoT device cybersecurity guidance for the federal government :
Fagan, M. E., Marron, J. A., Brady, K., Cuthill, B., Megas, K. N., & Herold, R. (2021) · doi:10.6028/nist.sp.800-213 · Cited by 55
Security Considerations in Modular Mobile Manipulation
Dieber, B., & Breiling, B. (2019) · IEEE International Conference on Robotic Computing (IRC) · doi:10.1109/irc.2019.00019 · Cited by 21
“The security in industrial systems has been a much discussed topic for years [6]–[8] also fuelled by more and more”
BackgroundHuang, L., & Zhu, Q. (2022) · Computers & Security · doi:10.1016/j.cose.2022.102844 · Cited by 28
Accurate Automata-Based Detection of Cyber Threats in Smart Grid Communication
Havlena, V., Matoušek, P., Ryšavý, O., & Holík, L. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3216726 · Cited by 20
“Cyber security of industrial systems, including smart grids, has thus become a huge challenge due to devastating attacks on critical infrastructure around the world [2], [3], [4], [5].”
BackgroundWang, J., Zhu, M. F., Li, M., Sun, Y., & Tian, Z. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3285992 · Cited by 25
“NIST SP-800-82 [6] gave guidance for the security protection of the industrial network, specifically to restrict logical access and network activity to the industrial network.”
BackgroundMethodIIoT Network Intrusion Detection Using Machine Learning
Eid, A. M., Nassif, A. B., Soudan, B., & Injadat, M. N. (2023) · International Conference on Intelligent Robotics and Control Engineering (IRCE) · doi:10.1109/irce59430.2023.10255088 · Cited by 26
“A number of works have expressly studied and discussed the significant differences between IIoT & IT systems [11], [12].”
BackgroundIntelligent Checkers to Improve Attack Detection in Cyber Physical Systems
Sabaliauskaite, G., & Mathur, A. P. (2013) · International Conference on Cyber-Enabled Distributed Computing and Knowledge Discovery (CyberC) · doi:10.1109/cyberc.2013.14 · Cited by 20
“Various security approaches can be implemented at individual levels or across several levels [5] [7].”
BackgroundDefense-in-depth vs. Critical Component Defense for Industrial Control Systems
Fielder, A., Li, T., & Hankin, C. (2016) · Electronic workshops in computing · doi:10.14236/ewic/ics2016.1 · Cited by 22
A Brief Introduction to Smart Grid Safety and Security
Khoussi, S., & Mattas, A. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803773-7.00011-5 · Cited by 20
Cybersecurity training in control systems using real equipment
Domínguez, M., Prada, M. A., Reguera, P., Fuertes, J. J., Alonso, S., & Morán, A. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.2151 · Cited by 24
Cybersecurity Enhancement of Transformer Differential Protection Using Machine Learning
Jahromi, M. Z., Jahromi, A. A., Sanner, S., Kundur, D., & Kassouf, M. (2020) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm41954.2020.9282161 · Cited by 25
“As such, different standards and initiatives have been launched by National Standard Institutes like ISA [4]–[6], research institutes like Electric Power Research Institute (EPRI) [7] and government agencies like Department of Energy (DOE) [8], [9] to develop cybersecurity measures/tools for cyber…”
BackgroundA Stealth Program Injection Attack against S7-300 PLCs
Alsabbagh, W., & Langendörfer, P. (2021) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit46573.2021.9453483 · Cited by 26
“The first step to protect our systems from various sorts of attacks is to improve the isolation from other networks [15], combining this with standard security practices [16], and even defence-in-depth security in the control systems.”
BackgroundAn approach to simulate gas-solid flow systems with process controllers
Li, S., & Shen, Y. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.132443 · Cited by 20
Security and Privacy Controls for Information Systems and OrganizationsPreprint
Joint Task Force Transformation Initiative (2020) · doi:10.6028/nist.sp.800-53r5-draft · Cited by 25
Measuring cyber resilience in industrial IoT: a systematic literature review
Lezzi, M., Corallo, A., Lazoi, M., & Nimis, A. (2025) · Management Review Quarterly · doi:10.1007/s11301-025-00495-8 · Cited by 38
A Formal Model and Technique to Redistribute the Packet Filtering Load in Multiple Firewall Networks
Durante, L., Seno, L., & Valenzano, A. (2021) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2021.3057552 · Cited by 20
“Typical examples are networked automation systems, factory networks and distributed critical infrastructures [1], [2], which have become more and more prone to cyber-attacks since they started to migrate from proprietary communication technologies to more open, Internet-based solutions, and where…”
BackgroundAttributions for ML-based ICS Anomaly Detection: From Theory to Practice
Fung, C., Zeng, E., & Bauer, L. (2024) · Network and Distributed System Security Symposium · doi:10.14722/ndss.2024.23216 · Cited by 37
“ICS collect information from the process through sensors and control the process through commands sent to actuators [60].”
BackgroundDeveloping Deception Network System with Traceback Honeypot in ICS Network
Abe, S., Tanaka, Y., Uchida, Y., & Horata, S. (2018) · SICE Journal of Control Measurement and System Integration · doi:10.9746/jcmsi.11.372 · Cited by 19
A Software-Defined Security Approach for Securing Field Zones in Industrial Control Systems
Yang, J. Y., Zhou, C., Tian, Y., & Yang, S. (2019) · IEEE Access · doi:10.1109/access.2019.2924800 · Cited by 20
Mitigating cyberattack related domino effects in process plants via ICS segmentation
Arief, R., Khakzad, N., & Pieters, W. (2020) · Journal of Information Security and Applications · doi:10.1016/j.jisa.2020.102450 · Cited by 19
An Empirical Study of TCP Vulnerabilities in Critical Power System Devices
Formby, D., Jung, S. S., Copeland, J. A., & Beyah, R. (2014) · doi:10.1145/2667190.2667196 · Cited by 19
“Previous guidelines, whitepapers, and reports on SCADA security requirements have pointed out weaknesses of security services that include lack of access controls, encryption of data, and security application deployment [1, 9, 11, 14, 15, 17].”
BackgroundAchieving ICS Resilience and Security through Granular Data Flow Management
Green, B., Krotofil, M., & Hutchison, D. (2016) · doi:10.1145/2994487.2994498 · Cited by 24
“From the National Institute of Standards and Technology (NIST), 800-53 [21], 800-30 [20], and 800-82 [32].”
BackgroundMethodInfluentialDenial-of-service in automation systems
Granzer, W., Reinisch, C., & Kästner, W. (2008) · IEEE International Conference on Emerging Technologies and Factory Automation (ETFA) · doi:10.1109/etfa.2008.4638438 · Cited by 19
Wireless User Requirements for the Factory Workcell
Montgomery, K. R., Candell, R., Liu, Y., & Hany, M. (2020) · doi:10.6028/nist.ams.300-8r1 · Cited by 19
Abdelghani, T. (2019) · American Journal of Artificial Intelligence · doi:10.11648/j.ajai.20190302.11 · Cited by 18
“[2, 6] An intrusion detection and protection system (IDS/IPS) monitors activity on the network for malicious traffic using different analysis like (penetration test), and logs and reports traffic anomalies to detect failures (like breaches in the network, or intruders) and secure immediately the systems.”
BackgroundEfficient Modelling of ICS Communication For Anomaly Detection Using Probabilistic Automata
Matoušek, P., Havlena, V., & Holík, L. (2021) · IFIP/IEEE International Symposium on Integrated Network Management (IM) · Cited by 34
Autonomous Attack Mitigation for Industrial Control Systems
Mern, J., Hatch, K., Silva, R., Hickert, C., Sookoor, T. I., & Kochenderfer, M. J. (2022) · International Conference on Dependable Systems and Networks workshops · doi:10.1109/dsn-w54100.2022.00015 · Cited by 25
Securing SCADA Energy Management System under DDos Attacks Using Token Verification Approach
Yang, Y., Lee, S., Chen, W.-C., Yang, C., Huang, Y.-M., & Hou, T. (2022) · Applied Sciences · doi:10.3390/app12010530 · Cited by 24
Etxezarreta, X., Garitano, I., Iturbe, M., & Zurutuza, U. (2023) · Wireless Networks · doi:10.1007/s11276-022-03212-5 · Cited by 18
“Industrial Control System (ICS) is a general term that covers several specialized elements used for monitoring and controlling industrial processes [1].”
BackgroundMethodSecurity architecture elements for IoT enabled automation networks
Fischer, K., & Gessner, J. (2012) · IEEE International Conference on Emerging Technologies and Factory Automation (ETFA) · doi:10.1109/etfa.2012.6489651 · Cited by 18
Design and Implementation of Industrial Firewall for Modbus/TCP
Shang, W., Qiao, Q., Wan, M., & Zeng, P. (2016) · Journal of Computers · doi:10.17706/jcp.11.5.432-438 · Cited by 18
“Industrial control systems have to face the traditional information security threats [1], [2].”
BackgroundA virtual testbed for security management of industrial control systems
Koganti, V. S., Ashrafuzzaman, M., Jillepalli, A. A., & Sheldon, F. T. (2017) · International Conference on Malicious and Unwanted Software · doi:10.1109/malware.2017.8323960 · Cited by 23
“Industrial Control System (ICS) is an umbrella term, which alludes to a collection of various control sub-systems; commonly including: a) the Supervisory Control and Data Acquisition (SCADA) systems, b) Distributed Control Systems (DCS), and c) Programmable Logic Controllers (PLC) [1].”
BackgroundMadhawa, S., Balakrishnan, P., & Umamakeswari, A. (2019) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/jifs-169946 · Cited by 22
“…infrastructure lead to immense loss as witnessed in the intentional attack on the German steel mill, Ukraine power plant and the Iranian nuclear plant, which also reveals the typical myths related to instigating assaults in IIoT [1] and the framework of NIST affirms the importance of security [3].”
Efficient Passive ICS Device Discovery and Identification by MAC Address Correlation
Niedermaier, M., Hanka, T., Plaga, S., von Bodisco, A., & Merli, D. (2018) · Electronic workshops in computing · doi:10.14236/ewic/ics2018.3 · Cited by 18
Artificial Intelligence and Security of Industrial Control Systems
Singh, S., Karimipour, H., HaddadPajouh, H., & Dehghantanha, A. (2020) · Springer eBooks · doi:10.1007/978-3-030-38557-6_7 · Cited by 32
ICS Testbed Tetris: Practical Building Blocks Towards a Cyber Security Resource
Green, B., Derbyshire, R., Knowles, W., Boorman, J., Ciholas, P., Prince, D., & Hutchison, D. (2020) · Lancaster EPrints (Lancaster University) · doi:10.5281/zenodo.4311805 · Cited by 18
PLC-Sleuth: Detecting and Localizing {PLC} Intrusions Using Control Invariants
Yang, Z., He, L., Cheng, P., Chen, J., Yau, D. K. Y., & Du, L. (2020) · Recent Advances in Intrusion Detection · Cited by 38
Chaos Engineering for Enhanced Resilience of Cyber-Physical Systems
Konstantinou, C., Stergiopoulos, G., Parvania, M., & Veríssimo, P. (2021) · Resilience Week (RWS) · doi:10.1109/rws52686.2021.9611797 · Cited by 29
Survey of cyber risk analysis techniques for use in the nuclear industry
Eggers, S. L., & Blanc, K. L. L. (2021) · Progress in Nuclear Energy · doi:10.1016/j.pnucene.2021.103908 · Cited by 33
DNP3 network scanning and reconnaissance for critical infrastructure
Rodofile, N. R., Radke, K., & Foo, E. (2016) · Australasian Computer Science Week Multiconference (ACSW) · doi:10.1145/2843043.2843350 · Cited by 18
“In this section we will review related work that have contributed methodologies to assist with network discovery techniques for SCADA-based critical infrastructure [9].”
MethodInfluentialA low-delay SDN-based countermeasure to eavesdropping attacks in industrial control systems
Ndonda, G. K., & Sadre, R. (2017) · IEEE Conference on Network Function Virtualization and Software Defined Networks (NFV-SDN) · doi:10.1109/nfv-sdn.2017.8169840 · Cited by 19
Towards Industrial Cybersecurity Resilience of Multinational Corporations
Lees, M. J., Crawford, M., & Jansen, C. (2018) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2018.11.201 · Cited by 18
Smart IDS and IPS for Cyber-Physical Systems
Mahboub, S. A., Ali, E. S., & Saeed, R. A. (2020) · Advances in systems analysis, software engineering, and high performance computing book series · doi:10.4018/978-1-7998-5101-1.ch006 · Cited by 18
Yang, Y.-S., Lee, S., Chen, W.-C., Yang, C.-S., Huang, Y.-M., & Hou, T.-W. (2021) · Sensors · doi:10.3390/s21082685 · Cited by 25
“At present, there are many successful cases in many related studies and practical cases, such as the application of the Supervisory Control and Data Acquisition (SCADA) [5] of ICS, which is applied in combination with the Programmable Logic Controller (PLC) [6] to realize the reservoir control Sensors 2021, 21, 2685.…”
BackgroundInfluentialAn Industrial Control System Physical Testbed for Naval Defense Cybersecurity Research
Sicard, F., Hotellier, E., & Francq, J. (2022) · IEEE European Symposium on Security and Privacy Workshops (EuroS&PW) · doi:10.1109/eurospw55150.2022.00049 · Cited by 17
Madhawa, S., Balakrishnan, P., & Umamakeswari, A. (2018) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/jifs-169670 · Cited by 18
“…on industrial infrastructure lead to immense loss as witnessed in the intentional attack on the German steel mill, Internet-facing control systems and Iranian nuclear plant, which also reveals the typical myths related to instigating assaults in IIoT [1] and the framework of NIST affirms it [3].”
CPS Security Assessment using Automatically Generated Attack Trees
Depamelaere, W., Lemaire, L., Vossaert, J., & Naessens, V. (2018) · Electronic workshops in computing · doi:10.14236/ewic/ics2018.1 · Cited by 17
“Two main attacker goals were identified based on the NIST guide to ICS security Stouffer et al. (2015): ModifyCPSBehavior and ObtainData.”
MethodSecuring industrial control system environments: the missing piece
Ani, U., Daniel, N., Oladipo, F. O., & Adewumi, S. E. (2018) · Journal of Cyber Security Technology · doi:10.1080/23742917.2018.1554985 · Cited by 27
“Researchers in [45] recommended the adoption of the NIST Guide to ICS Security, with speci fi c highlights security-oriented network architectures via network segregation practices, as well as disengaging redundant connections, and maintaining a closed loop (air gap) as much as possible.”
BackgroundMethodInfluentialCybersecurity management for distributed control system: systematic approach
Ali, S. (2021) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-020-02775-5 · Cited by 18
“The security techniques and management systems, once deployed, must be tested and evaluated to identify the strengths and weaknesses of the security approach (Scar-fone 2009; Stouffer et al. 2011b).”
BackgroundMethodInfluentialPrevention and mitigation measures against phishing emails: a sequential schema model
Suzuki, Y. E., & Monroy, S. A. S. (2021) · Security Journal · doi:10.1057/s41284-021-00318-x · Cited by 32
“Servers that must be accessed both by Internet users and sensitive servers can be placed in a special network compartment called a demilitarized zone (DMZ) (Stouffer et al. 2011; Tracy et al. 2002).”
BackgroundAn evaluation of cyber threats to industrial control systems
Vávra, J., & Hromada, M. (2015) · International Conference on Military Technologies · doi:10.1109/miltechs.2015.7153700 · Cited by 17
Forensic Readiness for SCADA/ICS Incident Response
Eden, P., Blyth, A., Burnap, P., Cherdantseva, Y., Jones, K., Soulsby, H., & Stoddart, K. (2016) · Electronic workshops in computing · doi:10.14236/ewic/ics2016.16 · Cited by 17
Investigation of Nanogrids for Improved Navy Installation Energy Resilience
Kain, A., Bossuyt, D. L. V., & Pollman, A. (2021) · Applied Sciences · doi:10.3390/app11094298 · Cited by 18
Metadata
- Authors
- Stouffer, K., Pillitteri, V., Lightman, S., Abrams, M., & Hahn, A.
- Published
- 2015-06
- OpenAlex
- W2619874920
- Cited by
- 1,377
- References
- 84
- Citations by year
- 2026: 63 · 2025: 85 · 2024: 56 · 2023: 105 · 2022: 90 · 2021: 139 · 2020: 154 · 2019: 137 · 2018: 119 · 2017: 99 · 2016: 102 · 2015: 64
- Type
- report
- Language
- en
- Update notices
- new_version (2023-09-28)
- Open access
- gold
- doi.org
- Funders
- U.S. Department of Homeland Security
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
- Physical Sciences › Computer Science › Information Systems › Information and Cyber Security
- Physical Sciences › Engineering › Control and Systems Engineering › Industrial Automation and Control Systems
- Keywords
- industrial control systems, ICS security, cybersecurity, federal information systems, information security standards, critical infrastructure protection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.