Guide to Industrial Control Systems (ICS) Security
Open accessThe DOI matches its Crossref record; 75 of the 84 references it cites were found in a registry or an index.
Abstract
This publication has been developed by NIST to further its statutory responsibilities under the Federal Information Security Modernization Act (FISMA) of 2014, 44 U.S.C. § 3541 et seq., Public Law (P.L.) 113-283.NIST is responsible for developing information security standards and guidelines, including minimum requirements for federal information systems, but such standards and guidelines shall not apply to national security systems without the express approval of appropriate federal officials exercising policy authority over such systems.This guideline is consistent with the requirements of the Office of Management and Budget (OMB) Circular A-130, Section 8b(3), Securing Agency Information Systems, as analyzed in Circular A-130, Appendix IV: Analysis of Key Sections. Supplemental information is provided in Circular A-130, Appendix III, Security of Federal Automated Information Resources.Nothing in this publication should be taken to contradict the standards and guidelines made mandatory and binding on federal agencies by the Secretary of Commerce under statutory authority.Nor should these guidelines be interpreted as altering or superseding the existing authorities of the Secretary of Commerce, Director of the OMB, or any other federal official.This publication may be used by nongovernmental organizations on a voluntary basis and is not subject to copyright in the United States.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The increased connectivity and automation capabilities of Industry 4.0 cyber-physical production systems (CPPS) create significant cyber-security vulnerabilities in supervisory control and data acquisition (SCADA) environments if robust protections are not properly implemented.”
From Seamless Industry 4.0 Integration: A Multilayered Cyber-Security Framework for Resilient SCADA Deployments in CPPS (2023) · cites this paper as [4]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This definition essentially eliminates any need for comparison of SCADA system with any other physical or cyberphysical and IoT or IIoT devices or concepts as any IT system performing these functions is a SCADA system in some physical form regardless of its design, structure or architecture.”
From SCADA Systems With Focus on Continuous Manufacturing and Steel Industry: A Survey on Architectures, Standards, Challenges and Industry 5.0 (2022) · cites this paper as [86]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“This exposes manufacturers to substantial risks of cyberattacks that could manipulate, disrupt, or disable critical physical assets and processes related to their production lines and facilities.”
From Seamless Industry 4.0 Integration: A Multilayered Cyber-Security Framework for Resilient SCADA Deployments in CPPS (2023) · cites this paper as [4]
The cited source says what the claim attributes to it.
In the citing paper
“SCADA connectivity to corporate environments also introduces cyber risks if not protected.”
From Seamless Industry 4.0 Integration: A Multilayered Cyber-Security Framework for Resilient SCADA Deployments in CPPS (2023) · cites this paper as [4]
The cited source says what the claim attributes to it.
In the citing paper
“Accordingly, there are multiple security recommendations and guidelines from relevant institutions such as the National Institute of Standards and Technology (NIST) [86] and U.S. Department of Homeland Security [187] providing incident response models.”
From SCADA Systems With Focus on Continuous Manufacturing and Steel Industry: A Survey on Architectures, Standards, Challenges and Industry 5.0 (2022) · cites this paper as [86]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Guidelines for Media Sanitization
Kissel, R., Regenscheid, A., Scholl, M., & Stine, K. (2014) · doi:10.6028/nist.sp.800-88r1 · Cited by 102
RetractedIdentifying, understanding, and analyzing critical infrastructure interdependencies
(2001) · IEEE Control Systems · doi:10.1109/37.969131 · Cited by 2,851 · cited 2×
“critical infrastructure is often referred to as a “system of systems” because of the interdependencies that exist between its various industrial sectors as well as interconnections between business partners [8] [9].”
BackgroundTödtling, F., & Trippl, M. (2005) · Research Policy · doi:10.1016/j.respol.2005.01.018 · Cited by 2,571
Guide to Intrusion Detection and Prevention Systems (IDPS)
Scarfone, K. A., & Mell, P. M. (2007) · doi:10.6028/nist.sp.800-94 · Cited by 1,279
Hiatt, J. M. (2003) · Cited by 664
Guide to Integrating Forensic Techniques into Incident Response
Kent, K., Chevalier, S., Grance, T., & Dang, H. (2006) · doi:10.6028/nist.sp.800-86 · Cited by 590
Cichonski, P., Millar, T., Grance, T., & Scarfone, K. (2012) · doi:10.6028/nist.sp.800-61r2 · Cited by 485
Security and Privacy Controls for Federal Information Systems and Organizations
Joint Task Force Transformation Initiative (2013) · doi:10.6028/nist.sp.800-53r4 · Cited by 470
Erickson, K. T., & Hedrick, J. L. (1999) · Wiley eBooks · Cited by 438
Framework for Improving Critical Infrastructure Cybersecurity, Version 1.1
National Institute of Standards and Technology (2018) · doi:10.6028/nist.cswp.04162018 · Cited by 386
Research works printed but not linked: 3
- Weiss, Joseph, "Current Status of Cybersecurity of Control Systems," Presentation to Georgia Tech Protective Relay Conference, May 8, 2003.
- Symantec Corporation, "Symantec Expands SCADA Protection for Electric Utilities," [press release], September 14, 2005, http://www.symantec.com/about/news/release/article.jsp?prid=20050914_01 [accessed 4/16/15].
- Scarfone, Karen, et al., NIST SP 800-48 Revision 1, Guide to Securing Legacy IEEE 802.11
Cited by
Items 101–200 of 1,003
Effect of Imbalanced Datasets on Security of Industrial IoT Using Machine Learning
Zolanvari, M., Teixeira, M. A., & Jain, R. (2018) · 2018 IEEE International Conference on Intelligence and Security Informatics (ISI) · doi:10.1109/isi.2018.8587389 · Cited by 71
“Through the fundamental differences between the ICSs and the regular IT systems, their common vulnerabilities and priorities are different [3].”
BackgroundA Dynamic Decision-Making Approach for Intrusion Response in Industrial Control Systems
Li, X., Zhou, C., Tian, Y., & Qin, Y. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2866445 · Cited by 81
“a security response exceeds the damage caused by the cyberattacks, a careful consideration is required to determine whether or not to implement the security response [4], [5].”
BackgroundSRID: State Relation Based Intrusion Detection for False Data Injection Attacks in SCADA
Wang, Y., Xu, Z., Zhang, J., Xu, L., Wang, H., & Gu, G. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-11212-1_23 · Cited by 87
“Unfortunately, we may not be confident enough to declare a secure SCADA system: Our existing system is still connected to vulnerable networks which integrate multiple communication protocols and lack proper data validation and authentication [5, 10, 23, 22].”
BackgroundDarkweb Cyber Threat Intelligence Mining
Robertson, J. W., Diab, A., Marin, E., Nunes, E., Paliath, V., Shakarian, J., & Shakarian, P. (2017) · Cambridge University Press eBooks · doi:10.1017/9781316888513 · Cited by 77
Managing Cyber Security Risks of the Cyber-Enabled Ship
Kavallieratos, G., & Katsikas, S. K. (2020) · Journal of Marine Science and Engineering · doi:10.3390/jmse8100768 · Cited by 97
Assessing IoT enabled cyber-physical attack paths against critical systems
Stellios, I., Kotzanikolaou, P., & Grigoriadis, C. (2021) · Computers & Security · doi:10.1016/j.cose.2021.102316 · Cited by 84
Towards effective security control assignment in the Industrial Internet of Things
Hassanzadeh, A., Modi, S., & Mulchandani, S. (2015) · 2015 IEEE 2nd World Forum on Internet of Things (WF-IoT) · doi:10.1109/wf-iot.2015.7389155 · Cited by 69
“Our analysis included multiple incidents across different industrial sectors, and highlights security controls which when activated appropriately, can improve prevention and detection of such attacks.”
BackgroundThe wireless control network: Monitoring for malicious behavior
Sundaram, S., Pajić, M., Hadjicostis, C. N., Mangharam, R., & Pappas, G. J. (2010) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2010.5717166 · Cited by 71
Cloud Manufacturing: Drivers, Current Status, and Future Trends
Wu, D., Greer, M. J., Rosen, D. W., & Schaefer, D. (2013) · doi:10.1115/msec2013-1106 · Cited by 71
“Stouffer et al. [10] discuss typical industrial control systems (ICSs) utilized in both process based and discretebased manufacturing environments, including Supervisory Control and Data Acquisition (SCADA), Distributed Control Systems (DCSs), and Programmable Logic Controllers (PLCs).”
BackgroundSverko, M., Grbac, T. G., & Mikuc, M. (2022) · IEEE Access · doi:10.1109/access.2022.3211288 · Cited by 71
“recommendations and guidelines from relevant institutions, such as the National Institute of Standards and Technology (NIST) [86] and the European Union Agency for Cybersecurity (ENISA) [188].”
BackgroundInfluentialAccurate Modeling of the Siemens S7 SCADA Protocol for Intrusion Detection and Digital Forensics
Kleinmann, A., & Wool, A. (2014) · The journal of digital forensics, security and law · doi:10.15394/jdfsl.2014.1169 · Cited by 86
A log mining approach for process monitoring in SCADA
Hadžiosmanović, D., Bolzoni, D., & Hartel, P. (2012) · International Journal of Information Security · doi:10.1007/s10207-012-0163-8 · Cited by 73
Verifying and Monitoring IoTs Network Behavior Using MUD Profiles
Hamza, A., Ranathunga, D., Gharakheili, H. H., Benson, T., Roughan, M., & Sivaraman, V. (2020) · IEEE Transactions on Dependable and Secure Computing · doi:10.1109/tdsc.2020.2997898 · Cited by 91
“In SCADA networks, the notation helps evaluate whether a MUD policy is compliant with industry-recommended practices in [39], [40].”
BackgroundHassan, M. M., Huda, S., Sharmeen, S., Abawajy, J., & Fortino, G. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.3015026 · Cited by 68
“Large industrial networks, such as smart grids, are segmented into smaller networks based on the uniform policy, level of trust, and functional criticality to isolate traffic [10]–[13].”
BackgroundMethodSynchronized Provable Data Possession Based on Blockchain for Digital Twin
Li, T., Wang, H., He, D., & Yu, J. (2022) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2022.3144869 · Cited by 71
Digital Transformation of Microgrids: A Review of Design, Operation, Optimization, and Cybersecurity
Irmak, E., Kabalcı, E., & Kabalcı, Y. (2023) · Energies · doi:10.3390/en16124590 · Cited by 81
Towards High-Interaction Virtual ICS Honeypots-in-a-Box
Antonioli, D., Agrawal, A., & Tippenhauer, N. O. (2016) · doi:10.1145/2994487.2994493 · Cited by 70
“We propose the design of a virtual, high-interaction and serverbased ICS honeypot to satisfy the requirements, and the deployment of a realistic, cost-effective, and maintainable ICS honeypot.”
Development of the PowerCyber SCADA security testbed
Hahn, A., Kregel, B., Govindarasu, M., Fitzpatrick, J., Adnan, R., Sridhar, S., & Higdon, M. (2010) · Proceedings of the Sixth Annual Workshop on Cyber Security and Information Intelligence Research · doi:10.1145/1852666.1852690 · Cited by 64
Self-citationDeriving a Cost-Effective Digital Twin of an ICS to Facilitate Security Evaluation
Bitton, R., Gluck, T., Stan, O., Inokuchi, M., Ohta, Y., Yamada, Y., Yagyu, T., Elovici, Y., & Shabtai, A. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-99073-6_26 · Cited by 93
Security Issues and Software Updates Management in the Industrial Internet of Things (IIoT) Era
Mugarza, I., Flores, J. L., & Montero, J. L. (2020) · Sensors · doi:10.3390/s20247160 · Cited by 65
“As claimed by NIST [25], the industrial control system security objectives usually follow as the next priorities: availability, integrity and confidentiality.”
BackgroundInfluentialAdversary-driven state-based system security evaluation
LeMay, E., Unkenholz, W. L., Parks, D. L., Muehrcke, C., Keefe, K., & Sanders, W. H. (2010) · International Workshop on Security Measurements and Metrics (MetriSec) · doi:10.1145/1853919.1853926 · Cited by 65
Securing IIoT using Defence-in-Depth: Towards an End-to-End secure Industry 4.0
Mosteiro-Sanchez, A., Barcelo, M., Astorga, J., & Urbieta, A. (2020) · Journal of Manufacturing Systems · doi:10.1016/j.jmsy.2020.10.011 · Cited by 64
“Critical devices and networks should have a redundant counterpart to replace the original in the event of failure or security breach [85].”
BackgroundInfluentialOperational Technology on Construction Sites: A Review from the Cybersecurity Perspective
Sonkor, M. S., & de Soto, B. G. (2021) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0002193 · Cited by 83
A method for evaluating the consequence propagation of security attacks in cyber–physical systems
Orojloo, H., & Azgomi, M. A. (2016) · Future Generation Computer Systems · doi:10.1016/j.future.2016.07.016 · Cited by 71
Security Challenges in Industry 4.0 PLC Systems
Hajda, J., Jakuszewski, R., & Ogonowski, S. (2021) · Applied Sciences · doi:10.3390/app11219785 · Cited by 78
Business Continuity and Disaster Recovery Planning for IT Professionals
(2007) · Elsevier eBooks · doi:10.1016/b978-1-59749-172-3.x5000-2 · Cited by 63
E-SFD: Explainable Sensor Fault Detection in the ICS Anomaly Detection System
Hwang, C., & Lee, T. (2021) · IEEE Access · doi:10.1109/access.2021.3119573 · Cited by 62
Railway Cyber-Security in the Era of Interconnected Systems: A Survey
Soderi, S., Masti, D., & Lun, Y. Z. (2023) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2023.3254442 · Cited by 88
Enhancing Cybersecurity in Smart Grids: False Data Injection and Its Mitigation
Unsal, D. B., Ustun, T. S., Hussain, S. M. S., & Önen, A. (2021) · Energies · doi:10.3390/en14092657 · Cited by 82
“Control systems used for different purposes can be found in the SG as follows [53] With these various purposes, the changes of paradigm, digitalization, standardization, and their impacts on the smart grids are summarized in Table 2.”
BackgroundInfluentialAn integrated safety and security analysis for cyber-physical harm scenarios
Guzman, N. H. C., KOZINE, I. O., & Lundteigen, M. A. (2021) · Safety Science · doi:10.1016/j.ssci.2021.105458 · Cited by 71
“…properties are usually summarized as the data confidentiality, integrity, and availability triad (CIA) and can be expanded with the inclusion of properties such as authenticity, nonrepudiation, among others (Dzung et al., 2005; IEC/TS 62443-1-1, 2009; ISO/IEC 27000, 2017; Stouffer et al., 2015).”
BackgroundWan, M., Shang, W., & Zeng, P. (2017) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2017.2730581 · Cited by 59
“In particular, we overcome the above difficulties from two aspects: on the one hand, industrial communication behaviors consider industrial communication protocols as the carriers to accomplish the automatic operation and management, mainly including process control and data acquisition [2].”
BackgroundA Role-Based Access Control Model in Modbus SCADA Systems. A Centralized Model Approach
Figueroa-Lorenzo, S., Añorga, J., & Arrizabalaga, S. (2019) · Sensors · doi:10.3390/s19204455 · Cited by 58
Vosughi, A., Tamimi, A., King, A. B., Majumder, S., & Srivastava, A. K. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112794 · Cited by 67
Resilience analysis of cyber‐physical systems: A review of models and methods
Cassottana, B., Roomi, M. M., Mashima, D., & Sansavini, G. (2023) · Risk Analysis · doi:10.1111/risa.14089 · Cited by 88
“…(ISO), for example, ISO 2700 (Brenner, 2007), the National Institute of Standards and Technology (NIST), for example, NIST SP 800-82 (Stouffer et al., 2011), NIST SP 800-53 (Force, 2017), NIST SP 800-72 (Barrett, 2018), and the Department of Homeland Security, for example, Common…”
BackgroundInfluentialGaber, T., Awotunde, J. B., Folorunso, S. O., Ajagbe, S. A., & Eldesouky, E. (2023) · Wireless Communications and Mobile Computing · doi:10.1155/2023/3939895 · Cited by 67
Control systems/SCADA forensics, what's the difference?
van der Knijff, R. M. (2014) · Digital Investigation · doi:10.1016/j.diin.2014.06.007 · Cited by 57
Li, X., Zhou, C., Tian, Y., Xiong, N. N., & Qin, Y. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2740571 · Cited by 62
“Impact assessment of cyberattacks is a vital part of risk analysis, which is a major pillar for evaluating the security resilience of ICSs to cyberattacks in general risk-based security protection [4], [5].”
BackgroundAccess control for cyber-physical systems interconnected to the cloud
López, J., & Rubio, J. E. (2018) · Computer Networks · doi:10.1016/j.comnet.2018.01.037 · Cited by 63
“Similarly, NIST SP80082 [31] proposes guidelines about the inclusion of security measures in control systems, giving recommendations on access control also when using wireless protocols and information technologies.”
Cyber-Attacks on the Oil & Gas Sector: A Survey on Incident Assessment and Attack Patterns
Stergiopoulos, G., Gritzalis, D. A., & Limnaios, E. (2020) · IEEE Access · doi:10.1109/access.2020.3007960 · Cited by 91
“To justify the numbers used inside the scale, we opted to review multiple sources of critical infrastructure impact [10], [59], [60], [62] along with the relevant, above mentioned standards and Directives like NIST, ISO and SEVESO-III 102].”
BackgroundInfluentialIoT, IIoT, and Cyber-Physical Systems Integration
Khujamatov, H., Reypnazarov, E. N., Khasanov, D., & Murodovich, A. N. (2021) · Advances in Science, Technology & Innovation/Advances in science, technology & innovation · doi:10.1007/978-3-030-66222-6_3 · Cited by 74
Critical Control System Protection in the 21st Century
Alcaraz, C., & Zeadally, S. (2013) · Computer · doi:10.1109/mc.2013.69 · Cited by 55
“To achieve this goal, it is necessary to implement access control mechanisms using well-defined roles and privileges as well as frequent tracking processes to control any abuse of activity/resource, or (external/internal) suspicious accesses [7].”
InfluentialSCADAVT-A framework for SCADA security testbed based on virtualization technology
Almalawi, A., Tari, Z., Khalil, I., & Fahad, A. (2013) · 38th Annual IEEE Conference on Local Computer Networks · doi:10.1109/lcn.2013.6761301 · Cited by 55
“Finally, we conclude the work in Section VII.”
MethodCyber-Security-Aware Network Design of Industrial Control Systems
Genge, B., Haller, P., & Kiss, I. (2015) · IEEE Systems Journal · doi:10.1109/jsyst.2015.2462715 · Cited by 55
Capitalizing on SDN-based SCADA systems: An anti-eavesdropping case-study
da Silva, E. G., Knob, L. A. D., Wickboldt, J. A., Gaspary, L. P., Granville, L. Z., & Schaeffer-Filho, A. E. (2015) · IFIP/IEEE International Symposium on Integrated Network Management (IM) · doi:10.1109/inm.2015.7140289 · Cited by 68
“These systems comprise distributed components, which are often dispersed around thousands of kilometers and allow the continuous data acquisition that is critical to the functioning of the power grid [2].”
BackgroundInfluentialCyber resilience in industrial networks: A state of the art, challenges, and future directions
Alrumaih, T. N. I., Alenazi, M. J. F., Alsowaygh, N. A. S., Humayed, A. A., & Alablani, I. A. (2023) · Journal of King Saud University - Computer and Information Sciences · doi:10.1016/j.jksuci.2023.101781 · Cited by 76
“…architecture and its hardware and software components; network vulnerabilities, related to channel protocols, communication, and permits; and procedure and policy vulnerabilities, related to security awareness, security training, and inadequate security operation management (Stouffer et al., 2011).”
Eid, A. M., Soudan, B., Nassif, A. B., & Injadat, M. (2024) · Neural Computing and Applications · doi:10.1007/s00521-024-09439-x · Cited by 53
ICS-BlockOpS: Blockchain for operational data security in industrial control system
Maw, A., Adepu, S., & Mathur, A. P. (2019) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2019.101048 · Cited by 60
Deep autoencoders as anomaly detectors: Method and case study in a distributed water treatment plant
Raman, M. R. G., Dong, W., & Mathur, A. P. (2020) · Computers & Security · doi:10.1016/j.cose.2020.102055 · Cited by 64
Mohammed, A. S., Reinecke, P., Burnap, P., RANA, O. F., & Anthi, E. (2022) · ACM Transactions on Cyber-Physical Systems · doi:10.1145/3548691 · Cited by 76
The industrial control system cyber defence triage process
Cook, A., Janicke, H., Smith, R., & Maglaras, L. A. (2017) · Computers & Security · doi:10.1016/j.cose.2017.07.009 · Cited by 54
“For most large ICS it is not cost-effective to hold a pre-production environment for the whole facility on which to test changes [39].”
BackgroundPower system effects and mitigation recommendations for DER cyberattacks
Johnson, J. D., Quiroz, J., Concepcion, R., Wilches‐Bernal, F., & Reno, M. J. (2019) · IET Cyber-Physical Systems Theory & Applications · doi:10.1049/iet-cps.2018.5014 · Cited by 52
Environment for Education on Industry 4.0
Fuertes, J. J., Prada, M. A., Ossorio, J. R. R., González-Herbón, R., Pérez, D., & Domínguez, M. (2021) · IEEE Access · doi:10.1109/access.2021.3120517 · Cited by 68
“A usual approach to improve cybersecurity is that of defense in depth, which consists in layering different security mechanisms to reduce the chance of a successful attack [44].”
BackgroundAnalysis of requirements for critical control systems
Alcaraz, C., & López, J. (2012) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2012.08.003 · Cited by 50
Häring, I., Sansavini, G., Bellini, E., Martyn, N., Kovalenko, T., Kitsak, M., Vogelbacher, G., Roß, K., Bergerhausen, U., Barker, K., et al. (2017) · NATO science for peace and security series. C, Environmental security · doi:10.1007/978-94-024-1123-2_2 · Cited by 56
Easing the Conscience with OPC UA: An Internet-Wide Study on Insecure Deployments
Dahlmanns, M., Lohmöller, J., Fink, I. B., Pennekamp, J., Wehrle, K., & Henze, M. (2020) · ACM Internet Measurement Conference (IMC) · doi:10.1145/3419394.3423666 · Cited by 69
“Config-uration recommendations [52] as well as general security advice for industrial control systems [63] and generic security guidelines, e.g., on the use of certificates [2, 52] and hash functions [12, 18], aid this task.”
BackgroundSoftware defined networking firewall for industry 4.0 manufacturing systems
Tsuchiya, A., Fraile, F., Koshijima, I., Ortiz, A., & Poler, R. (2018) · Journal of Industrial Engineering and Management · doi:10.3926/jiem.2534 · Cited by 49
Cyber Security Assessment of Distributed Energy Resources
Carter, C., Onunkwo, I., Cordeiro, P., & Johnson, J. (2017) · Conference record of the IEEE Photovoltaic Specialists Conference · doi:10.1109/pvsc.2017.8366503 · Cited by 49
“Per NIST [19], “Without proper and accurate logs, it might be impossible to determine what caused a security event to occur.”
BackgroundStateful intrusion detection for IEC 60870-5-104 SCADA security
Yang, Y., McLaughlin, K., Sezer, S., Yuan, Y., & Huang, W. (2014) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2014.6939218 · Cited by 68
“NIST further recommends additional rule sets for SCADA applications [6].”
A Threat Hunting Framework for Industrial Control Systems
Jadidi, Z., & Lu, Y. (2021) · IEEE Access · doi:10.1109/access.2021.3133260 · Cited by 48
“Now, the majority of old technologies have been replaced by low-cost Ethernet and Internet Protocol (IP)based devices, and hence the possibility of cybersecurity incidents has been increased [48].”
BackgroundCybersecurity framework manufacturing profile
Stouffer, K. A., Zimmerman, T., Tang, C., Lubell, J., Cichonski, J., & McCarthy, J. (2017) · doi:10.6028/nist.ir.8183 · Cited by 48
Self-citationZhao, Y., Huang, L., Smidts, C. S., & Zhu, Q. (2020) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2020.106878 · Cited by 53
Modeling Security of Power Communication Systems Using Defense Graphs and Influence Diagrams
Sommestad, T., Ekstedt, M., & Nordstrom, L. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2028796 · Cited by 46
Formal Vulnerability Analysis of a Security System for Remote Fieldbus Access
Cheminod, M., Pironti, A., & Sisto, R. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2010.2099233 · Cited by 49
Suleiman, H., & Svetinović, D. (2012) · Requirements Engineering · doi:10.1007/s00766-012-0153-4 · Cited by 56
Industrial Wireless Systems Guidelines: Practical Considerations and Deployment Life Cycle
Candell, R., Kashef, M., Liu, Y., Lee, K. B., & Foufou, S. (2018) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2018.2873820 · Cited by 49
Microgrid Cyber Security Reference Architecture (V.1.0)
Sandia National Labs., A., Veitch, C., (NNSA), U. N. N. S. A., Henry, J., Richardson, B., & Hart, D. (2013) · doi:10.2172/1090210 · Cited by 45
Guide for security-focused configuration management of information systems
Johnson, A., Dempsey, K., Ross, R., Gupta, S., & Bailey, D. (2019) · doi:10.6028/nist.sp.800-128 · Cited by 45
Etxezarreta, X., Garitano, I., Iturbe, M., & Zurutuza, U. (2023) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2023.100615 · Cited by 56
CPAC: securing critical infrastructure with cyber-physical access control
Etigowni, S., Tian, D. J., Hernandez, G., Zonouz, S., & Butler, K. R. B. (2016) · Annual Computer Security Applications Conference · doi:10.1145/2991079.2991126 · Cited by 52
“Stouffer et al. [57] present a series of NIST guideline security architectures for the industrial control systems that cover supervisory control and data acquisition systems, distributed control systems, and PLCs.”
BackgroundCyber Resilience Framework for Industrial Control Systems: Concepts, Metrics, and Insights
Haque, M. A., Teyou, G. K. D., Shetty, S. S., & Krishnappa, B. (2018) · IEEE International Conference on Intelligence and Security Informatics (ISI) · doi:10.1109/isi.2018.8587398 · Cited by 44
Cyber risk management for autonomous passenger ships using threat-informed defense-in-depth
Amro, A., & Gkioulos, V. (2022) · International Journal of Information Security · doi:10.1007/s10207-022-00638-y · Cited by 58
Improving cybersecurity for Industrial Control Systems
Graham, J., Hieb, J., & Naber, J. (2016) · 2016 IEEE 25th International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2016.7744960 · Cited by 43
“A Representative SCADA System (From [7])”
Kavallieratos, G., Spathoulas, G. P., & Katsikas, S. K. (2021) · Sensors · doi:10.3390/s21051691 · Cited by 58
“The list of available cybersecurity controls has been defined based on the NIST guidelines for Industrial Control Systems security [5] by following a systematic process proposed in Reference [44].”
MethodImplementation of Secure Communication With Modbus and Transport Layer Security protocols
Ferst, M. K., de Figueiredo, H. F. M., Denardin, G., & Lopes, J. (2018) · 2018 13th IEEE International Conference on Industry Applications (INDUSCON) · doi:10.1109/induscon.2018.8627306 · Cited by 41
“[1] presents a guide to industrial control systems security and [18] defines a methodology for risk assessment in industrial automation systems, which identifies possible security threats and the respective countermeasures.”
BackgroundDetection of Man-in-the-Middle Attacks on Industrial Control Networks
Eigner, O., Kreimel, P., & Tavolato, P. (2016) · International Conference on Software Security and Assurance (ICSSA) · doi:10.1109/icssa.2016.19 · Cited by 50
“• The interconnection of CPSs with corporate networks and the Internet increases the attack surface.”
BackgroundInfluentialAn introduction to buildings cybersecurity framework
Mylrea, M., Gourisetti, S. N. G., & Nicholls, A. K. (2017) · IEEE Symposium Series on Computational Intelligence (SSCI) · doi:10.1109/ssci.2017.8285228 · Cited by 43
“• National Institute of Standards and Technology Special Publication 800-82 R2 Guide to Industrial Control Systems (ICS) Security 2015 [22]”
BackgroundMethodMeasuring cyber-physical security in industrial control systems via minimum-effort attack strategies
Barrère, M., Hankin, C., Nicolaou, N., Eliades, D. G., & Parisini, T. (2020) · Journal of Information Security and Applications · doi:10.1016/j.jisa.2020.102471 · Cited by 49
Izadi, M., Hosseinian, S. H., Dehghan, S., Fakharian, A., & Amjady, N. (2020) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12680 · Cited by 50
Al-Hawawreh, M., & Sitnikova, E. (2019) · Military Communications and Information Systems Conference · doi:10.1109/milcis.2019.8930732 · Cited by 33
“The ICSs often utilize these workstation interfaces such as Object Linking and Embedding protocol (OLE) for process control, NetBIOS, and Server Message Block (SMB) for configuration and implementation processes [4].”
MethodChen, S., Wu, Z., & Christofides, P. D. (2020) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2020.10.014 · Cited by 49
“As fundamental process safety can be compromised due to these intelligent cyber-attacks, safe-guarding measures must be considered and incorporated in plant-wide risk assessments (Stouffer et al., 2011).”
BackgroundCheong, A., Yoon, K., Cho, S., & No, W. G. (2020) · Journal of Information Systems · doi:10.2308/isys-2020-031 · Cited by 75
A secure distributed ledger for transactive energy: The Electron Volt Exchange (EVE) blockchain
Saha, S. S., Ravi, N., Hreinsson, K., Baek, J., Scaglione, A., & Johnson, N. G. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.116208 · Cited by 42
Security-Oriented Cloud Platform for SOA-Based SCADA
Baker, T., Mackay, M., Shaheed, A., & Aldawsari, B. (2015) · 2015 15th IEEE/ACM International Symposium on Cluster, Cloud and Grid Computing · doi:10.1109/ccgrid.2015.37 · Cited by 38
“From the above, there are clearly a set of major hindrances to accomplishing secure SCADA-based critical infrastructure: Role based access control and different views on how systems should be configured, viewed and used [7], need to be fulfilled in order to securely use the system and current SOA 2015 15th IEEE/ACM In…”
MethodCybersecurity protection for power grid control infrastructures
Jarmakiewicz, J., Parobczak, K., & Maślanka, K. (2017) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2017.07.002 · Cited by 41
“Moreover, in the case of power grid control systems, the cost of potential damage is too high to use off-the-shelf protection measures [58].”
BackgroundLogarithmic encryption scheme for cyber–physical systems employing Fibonacci Q-matrix
Zhou, T., Shen, J., Li, X., Wang, C., & Tan, H. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2018.04.008 · Cited by 41
Detecting stealthy attacks against industrial control systems based on residual skewness analysis
Hu, Y., Li, H., Yang, H. T., Sun, Y., Sun, L., & Wang, Z. (2019) · EURASIP Journal on Wireless Communications and Networking · doi:10.1186/s13638-019-1389-1 · Cited by 43
“1 Introduction Nowadays, industrial control systems (ICS) [1] play a very important role in national critical infrastructures, such as smart grids [2–4], water treatment systems [5], chemical processing plants [6], oil and natural gas pipelines [7], or large-scale communication systems [8].”
BackgroundAnalysis of Machine Learning Methods in EtherCAT-Based Anomaly Detection
Akpinar, K. O., & Özçelik, İ. (2019) · IEEE Access · doi:10.1109/access.2019.2960497 · Cited by 42
“NIST recommends that security in the Purduemodel can be enhanced by adding monitoring systems such as intrusion detection/prevention systems (IDS/IPS), security information and eventmanagement (SIEM) software, and log aggregators, and by placing firewalls at all levels as a zone access point for inter-regional communi…”
BackgroundA three-tiered intrusion detection system for industrial control systems
Anthi, E., Williams, L., Burnap, P., & Jones, K. (2021) · Journal of Cybersecurity · doi:10.1093/cybsec/tyab006 · Cited by 46
Enterprise architecture models for cyber security analysis
Ekstedt, M., & Sommestad, T. (2009) · IEEE PES Power Systems Conference and Exposition · doi:10.1109/psce.2009.4840267 · Cited by 39
Critical infrastructure protection against cyber threats
laitos, S., & Vankka, J. (2014) · Doria (University of Helsinki) · Cited by 39
Security Viewpoint in a Reference Architecture Model for Cyber-Physical Production Systems
Ma, Z., Hudic, A., Shaaban, A., & Plosz, S. (2017) · 2017 IEEE European Symposium on Security and Privacy Workshops (EuroS&PW) · doi:10.1109/eurospw.2017.65 · Cited by 38
“They are different in many ways from enterprise IT systems [9].”
BackgroundSecurity challenges and methods for protecting critical infrastructure cyber-physical systems
Taylor, J. M., & Sharif, H. (2017) · International Conference on Selected Topics in Mobile and Wireless Networking (MoWNeT) · doi:10.1109/mownet.2017.8045959 · Cited by 38
“Security needs extend beyond control center [3].”
BackgroundProtecting cyber physical production systems using anomaly detection to enable self-adaptation
Settanni, G., Skopik, F., Karaj, A., Wurzenberger, M., & Fiedler, R. (2018) · 2018 IEEE Industrial Cyber-Physical Systems (ICPS) · doi:10.1109/icphys.2018.8387655 · Cited by 35
“The American National Institute of Standards and Technology (NIST) catalogs threats potentially affecting industrial control systems in: control logic manipulation, malware, denial of control actions, and spoofed system status [5].”
BackgroundpowerLang: a probabilistic attack simulation language for the power domain
Hacks, S., Katsikeas, S., Ling, E. R., Lagerström, R., & Ekstedt, M. (2020) · Energy Informatics · doi:10.1186/s42162-020-00134-4 · Cited by 48
“The central asset on this layer is the ControlServer which operates the Controller on level 1 and also computes their output (Stouffer et al. 2011).”
BackgroundTowards Secure IoT Communication with Smart Contracts in a Blockchain Infrastructure
Ali, J., Syed, T. A., Musa, S., & Zahrani, A. (2018) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2018.091070 · Cited by 52
“…systems composed of numerous sub-systems, such as Supervisory control and data acquisition (SCADA), distributed control systems (DCS), other smaller systems, including programmable logic controllers (PLCs), remote terminal units (RTUs), and others involved in running an industrial operation [4].”
Liu, Z., & Wang, L. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3222309 · Cited by 40
“NIST has suggested how to applied more advanced cyber technologies and process to improve the recovery of the control systems after attacks [24].”
MethodA statistical method for detecting cyber/physical attacks on SCADA systems
van Long, Fillatre, L., & Nikiforov, I. V. (2014) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/cca.2014.6981373 · Cited by 43
“Supervisory Control and Data Acquisition (SCADA) systems are highly distributed systems used to control geographically dispersed assets, often scattered over thousands of square kilometers, where centralized data acquisition and control are critical to system operation [1].”
BackgroundControl Behavior Integrity for Distributed Cyber-Physical Systems
Adepu, S., Brasser, F., García, L. A. R., Rodler, M., Davi, L., Sadeghi, A., & Zonouz, S. (2020) · ACM/IEEE International Conference on Cyber-Physical Systems (ICCPS) · doi:10.1109/iccps48487.2020.00011 · Cited by 41
“…systems across several applications of industrial sectors and critical infrastructures, including electric power transmission and distribution, oil and natural gas production, refinery operations, water treatment systems, wastewater collection systems, as well as pipeline transport systems [64].”
BackgroundInfluentialVulnerability Modelling for Hybrid Industrial Control System Networks
Ur-Rehman, A., Gondal, I., Kamruzzaman, J., & Jolfaei, A. (2020) · Journal of Grid Computing · doi:10.1007/s10723-020-09528-w · Cited by 45
“These tools were designed basically for IT computer networks and do not best fit due to the unique characters of the ICS system [9].”
MethodExperimental assessment of network design approaches for protecting industrial control systems
Genge, B., Graur, F., & Haller, P. (2015) · International Journal of Critical Infrastructure Protection · doi:10.1016/j.ijcip.2015.07.005 · Cited by 36
Metadata
- Authors
- Stouffer, K., Pillitteri, V., Lightman, S., Abrams, M., & Hahn, A.
- Published
- 2015-06
- OpenAlex
- W2619874920
- Cited by
- 1,377
- References
- 84
- Citations by year
- 2026: 63 · 2025: 85 · 2024: 56 · 2023: 105 · 2022: 90 · 2021: 139 · 2020: 154 · 2019: 137 · 2018: 119 · 2017: 99 · 2016: 102 · 2015: 64
- Type
- report
- Language
- en
- Update notices
- new_version (2023-09-28)
- Open access
- gold
- doi.org
- Funders
- U.S. Department of Homeland Security
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
- Physical Sciences › Computer Science › Information Systems › Information and Cyber Security
- Physical Sciences › Engineering › Control and Systems Engineering › Industrial Automation and Control Systems
- Keywords
- industrial control systems, ICS security, cybersecurity, federal information systems, information security standards, critical infrastructure protection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.