PreprintCited by 0Artificial Intelligence in Healthcare and EducationClinical Reasoning and Diagnostic SkillsArtificial Intelligence in Healthcare

Do Calibrated-Probability Claims Hold Up in Clinical Diagnosis? A Pre-registered Evaluation of a Decision Model Against Frontier Language Models

Open access
Deobhakta, Avnish, Chang, Jonathan, Chen, Royce W.S., Jaipalli, Sujai, Pinhas, Alexander, Tania Tai, Tak Yee, Rosen, Richard B.·2026·medRxiv

Abstract

Background: A new class of AI “decision models” returns a probability for every option in a single pass and is marketed as calibrated, which invites use in clinical triage. Whether those probabilities hold up on clinical diagnosis has not been independently tested. Objective: To test the diagnostic accuracy, calibration, and probabilistic coherence of a decision model (Jev 1.13, TypeSafe AI) against frontier language models, with and without reasoning. Methods: In a pre-registered study (OSF, registered 26 September 2026), we compared Jev with Claude Opus 5.5 (adaptive reasoning, always on) and Claude Opus 5 (reasoning disabled) on three case sets: the 45 Semigran symptom-checker vignettes, 1,000 stratified synthetic patients from DDXPlus with reference differentials, and 80 simulated ophthalmic complaints (40 diagnoses at two levels of detail). Each model returned a probability for every diagnosis on a fixed list. Outcomes were top-1 and top-3 accuracy, expected calibration error (ECE), Brier score, the rate of exactly zero probability on the true diagnosis, sensitivity to option order, behavior on uninformative inputs, and behavior when the true diagnosis was absent. Results: On DDXPlus, top-1 accuracy was 72.0% for Jev, 79.5% for Opus 5 without reasoning, and 87.4% for Opus 5.5 (both comparisons with Jev P<.001). Jev assigned exactly zero probability to the true diagnosis in 62 of 1,000 cases (6.2%); neither comparator did so in any case. Calibration error did not differ between Jev and the registered comparator (ECE difference 0.007, 95% CI -0.026 to 0.038). Offered an explicit “none of these” option, Jev declined to diagnose all 30 uninformative inputs; without that option, it assigned a mean 58% to a single diagnosis. Order sensitivity was small in all models. Given the option list with no patient information, Jev placed up to 96% on a single diagnosis, while the comparators spread probability almost evenly. On the ophthalmic complaints, accuracy did not differ (Jev 88.8%, Opus 5 91.2%, Opus 5.5 88.8%), and Jev was better calibrated than the registered comparator (ECE difference -0.081, 95% CI -0.124 to -0.018). Conclusions: The decision model matched frontier models on short, distinctive ophthalmic complaints but fell well behind on multi-symptom synthetic patients, including behind a comparator without reasoning, and there it excluded the correct diagnosis outright in about 1 in 16 cases. Its probabilities signaled uncertainty only when the question offered a way to abstain. Calibration claims for clinical decision models should be tested on clinical tasks, with explicit abstention options and zero-probability rates reported.

AI snapshot

Written from the paper’s full text.

TL;DR

In a pre-registered evaluation, a single-pass “decision model” (Jev 1.13) matched frontier language models on short ophthalmic complaints but was substantially less accurate on 1,000 multi-symptom synthetic DDXPlus patients, where it assigned exactly zero probability to the correct diagnosis in 6.2% of cases. Its probabilities signaled uncertainty only when an explicit abstention option was offered.

Key findings

  • On DDXPlus (n=1,000), top-1 accuracy was 72.0% for Jev, 79.5% for Opus 5 without reasoning, and 87.4% for Opus 5.5 (both Jev comparisons P<.001). Jev assigned exactly zero probability to the true diagnosis in 62 of 1,000 cases (6.2%); neither comparator did so in any case.
  • Calibration error did not differ between Jev and the registered comparator Opus 5.5 on DDXPlus (ECE difference 0.007, 95% CI -0.026 to 0.038), but Opus 5 was better calibrated. On the 80 ophthalmic complaints, accuracy did not differ (Jev 88.8%, Opus 5 91.2%, Opus 5.5 88.8%), and Jev was better calibrated than Opus 5.5 (ECE difference -0.081, 95% CI -0.124 to -0.018).
  • On 30 uninformative inputs with forced choice, Jev placed a mean 58% on its top diagnosis, versus 37% for Opus 5 and 21% for Opus 5.5; when “none of these” was offered, Jev chose it for all 30 inputs (mean probability 0.82). Given only the option list with no patient information, Jev placed up to 96% on a single diagnosis, while comparators spread probability almost evenly.
  • On Semigran-45, no pairwise difference in accuracy or calibration was significant.

Methods

  • Pre-registered cross-sectional evaluation (OSF, registered 26 September 2026) comparing Jev 1.13 with Claude Opus 5.5 (adaptive reasoning, always on) and Claude Opus 5 (reasoning disabled) on three case sets: 45 Semigran symptom-checker vignettes, 1,000 stratified synthetic DDXPlus patients with reference differentials, and 80 simulated ophthalmic complaints (40 diagnoses at two levels of detail), plus 30 uninformative inputs. Each model returned a probability for every diagnosis on a fixed list.
  • Outcomes included top-1 and top-3 accuracy, expected calibration error (10 equal-width bins on top-1 confidence), Brier score, rate of exactly zero probability on the true diagnosis, sensitivity to option order, behavior on uninformative inputs, and behavior when the true diagnosis was absent.
  • Paired comparisons used exact McNemar tests for binary outcomes and case-level bootstrap intervals (10,000 resamples; 2,000 for calibration error) for continuous outcomes, with Holm correction across registered primary comparisons. Deviations from the registered plan are reported.

Limitations

  • The paper states: all cases were written, not spoken, and none came from real patients; DDXPlus patients are synthetic and the template rendering is stilted. The Claude models may have seen public case sets in training, while Jev’s training data are undisclosed. Semigran and the ophthalmic set were too small to detect moderate differences. Registered hypotheses on irrelevant options and paraphrases were not run. Opus 5.5’s resolved version carried no dated snapshot identifier. Jev’s 0.01 output resolution makes its noise and distance measures coarser. All three models are commercial products that change.
  • The paper also states: the ophthalmic set comprised 80 simulated complaints, a small sample of uncertain applicability to real patient calls; evaluation on real triage messages with known outcomes is needed. Each case was presented as a single message, whereas real triage is a conversation; Jev cannot ask for clarification, and the study did not test whether the language models’ ability to do so would change accuracy.
  • Evident from the text: the study evaluates diagnostic accuracy and calibration on written/synthetic cases, not clinical outcomes from real triage workflows; the manuscript and analysis harness were written with assistance from Claude, the same model family used as comparator, though the paper states safeguards including pre-registration, public code, and author review.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.64898/2026.10.09.26365153

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

8 of 19 cited sources checked · 2 supported · 1 flagged · accuracy not yet measured

  • Premisecitation

    Miscalibration is a distinct hazard from inaccuracy.

    “Miscalibration is a distinct hazard from inaccuracy [3].”
    Quote in the paperSubstantial claim1 of 1 sources checked
    • cites [3] source

      In “Discrimination is important, but are the risk estimates reliable?”, the paper calls calibration the accuracy of risk estimates. Its section “How can inaccurate risk predictions be misleading?” then describes poorly calibrated estimates as inaccurate. The paper distinguishes miscalibration from poor discrimination, not from inaccuracy. (LLM, conf=0.87)

      Checked by a reasoning model — may be wrong.

      Experimental — accuracy not yet measured
  • Premisecitation

    General-purpose language models on standardized clinical vignettes diagnose and triage at levels approaching those of physicians.

    “On standardized clinical vignettes, general-purpose language models already diagnose and triage at levels approaching those of physicians [5,6]”
    Quote in the paperSubstantial claim2 of 2 sources checked
    • cites [5] source

      The Results (page not available in our copy) report that GPT-3 identified the correct diagnosis among its top three in 88% of vignettes, compared with 96% for physicians, supporting the diagnostic comparison. But its triage accuracy was 70% versus 91% for physicians; the Discussion describes triage as inferior to both physicians and lay individuals. The claim overstates how closely triage approached physician performance and generalizes a finding about GPT-3 to language models broadly. (LLM, conf=0.90)

      Experimental — accuracy not yet measured
    • cites [6] source
  • Findingown data

    On DDXPlus, Jev's top-1 accuracy was 72.0%.

    “On DDXPlus, top-1 accuracy was 72.0% for Jev, 79.5% for Opus 5 without reasoning, and 87.4% for Opus 5.5”
    Quote in the paperSubstantial claim
  • Findingown data

    On DDXPlus, Opus 5 without reasoning top-1 accuracy was 79.5%.

    “On DDXPlus, top-1 accuracy was 72.0% for Jev, 79.5% for Opus 5 without reasoning, and 87.4% for Opus 5.5”
    Quote in the paperSubstantial claim
  • Findingown data

    On DDXPlus, Jev's top-1 accuracy was lower than Opus 5 without reasoning (P<.001).

    “On DDXPlus, Jev's top-1 accuracy was lower than that of Opus 5 without reasoning (only Jev correct in 45 cases, only Opus 5 correct in 120; P<.001)”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim. 29
  • May combine two claims. 37
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductcitation

    Reporting follows the TRIPOD-LLM guideline for studies using large language models.

    “Reporting follows the TRIPOD-LLM guideline for studies using large language models [11], and a completed checklist is provided as a supplementary file.”
    Quote in the paperNot a substantial claim1 of 1 sources checked
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductcitation

    The Lyons ophthalmic set was replaced by the registered Zandi set, because its vignette text is published only as an image.

    “The Lyons ophthalmic set [16] was replaced by the registered Zandi set, because its vignette text is published only as an image.”
    Quote in the paperNot a substantial claim1 of 1 sources checked
    • cites [16] source

      The Clinical vignette design section confirms that Lyons and colleagues developed an ophthalmic vignette set, so the citation identifies the set correctly. Our copy does not establish that its vignette text was published only as an image. The replacement with the Zandi set is the citing authors’ decision, not a finding attributed to Lyons. (LLM, conf=0.83)

      Experimental — accuracy not yet measured
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Earlier vignette studies found high diagnostic accuracy for language models on Semigran-style cases, and one found their stated confidence reasonably calibrated by Brier score.

    “Earlier vignette studies found high diagnostic accuracy for language models on Semigran-style cases, and one found their stated confidence reasonably calibrated by Brier score [5,6]”
    Quote in the paperNot a substantial claim2 of 2 sources checked
    • cites [5] source

      The Results report 88% top-three diagnostic accuracy on 48 synthetic vignettes and good diagnostic calibration (Brier score 0.18). The Methods say the cases built on symptom-checker work, but the confidence scores were calculated from how often GPT-3 repeated a diagnosis across prompts; they were not confidence values stated by the model. (LLM, conf=0.86)

      Experimental — accuracy not yet measured
    • cites [6] source

      The Methods (Overview; page unavailable) describe testing LLMs on 48 synthetic clinical vignettes, and the Results (page unavailable) report high diagnostic accuracy. The copy does not identify these as Semigran-style cases, and a search for Brier score and confidence calibration found no such assessment. Thus, it supports the accuracy portion but not the case provenance or calibration portion. (LLM, conf=0.84)

      Experimental — accuracy not yet measured
  • Classified as probably not a substantial claim.

    Premisecitation

    A triage system using model probabilities works only if the probabilities are calibrated, meaning a stated probability matches how often the model is actually right.

    “Such a system works only if the probabilities are calibrated, meaning that a stated probability matches how often the model is actually right [3].”
    Quote in the paperSubstantial claim1 of 1 sources checked
    • cites [3] source

      The paper defines calibration as agreement between estimated risk and observed event frequency (Main text, “How to assess calibration?”). It says calibration is especially important for decision-making and that poor calibration can lead to harmful decisions (Main text, “Discrimination is important, but are the risk estimates reliable?”; Conclusions). It does not establish the absolute claim that a probability-based triage system works only if its probabilities are calibrated. (LLM, conf=0.86)

      Experimental — accuracy not yet measured
  • May combine two claims.

    Findingown data

    On the 30 uninformative inputs with a forced choice, Jev placed a mean 58% on its top diagnosis, compared with 37% for Opus 5 and 21% for Opus 5.5.

    “On the 30 uninformative inputs with a forced choice, Jev placed a mean 58% on its top diagnosis, compared with 37% for Opus 5 and 21% for Opus 5.5.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    On the matched comparison, Jev was more order-sensitive than Opus 5.5 (excess TVD difference 0.015; 95% CI 0.005 to 0.025) and did not differ from Opus 5.

    “On the matched comparison, Jev was more order-sensitive than Opus 5.5 (excess TVD difference 0.015; 95% CI 0.005 to 0.025) and did not differ from Opus 5.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    On the 80 ophthalmic complaints, top-1 accuracy did not differ between Jev and either comparator (only Jev correct in 3 cases vs 5 for Opus 5, P=.73; 3 vs 3 for Opus 5.5, P>.99).

    “On the 80 ophthalmic complaints, top-1 accuracy did not differ between Jev and either comparator (only Jev correct in 3 cases vs 5 for Opus 5, P=.73; 3 vs 3 for Opus 5.5, P>.99).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    On DDXPlus, Opus 5 was better calibrated than both Jev and Opus 5.5.

    “Opus 5 was better calibrated than both.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Shuffling the option order changed all three models' outputs slightly more than rerunning them did (mean excess TVD 0.025 for Jev, 0.034 for Opus 5, 0.019 for Opus 5.5; all P<.001), but rarely changed the top diagnosis.

    “Shuffling the option order changed all three models' outputs slightly more than rerunning them did (mean excess TVD 0.025 for Jev, 0.034 for Opus 5, 0.019 for Opus 5.5; all P<.001), but rarely changed the top diagnosis.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Jev was better calibrated than Opus 5.5 on the ophthalmic complaints (ECE difference -0.081; 95% CI -0.124 to -0.018) and did not differ from Opus 5 (-0.057; 95% CI -0.095 to 0.015).

    “Jev was better calibrated than Opus 5.5 (ECE difference -0.081; 95% CI -0.124 to -0.018) and did not differ from Opus 5 (-0.057; 95% CI -0.095 to 0.015).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Jev did not differ from either comparator in order sensitivity.

    “Jev did not differ from either comparator.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Jev's and Opus 5's top-1 errors on DDXPlus were moderately correlated (phi 0.57), more so than Jev's and Opus 5.5's (phi 0.46).

    “Jev's and Opus 5's top-1 errors on DDXPlus were moderately correlated (phi 0.57), more so than Jev's and Opus 5.5's (phi 0.46).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Opus 5.5 reasoned before answering on 41.2% of DDXPlus cases and on 10 of 45 Semigran cases.

    “Opus 5.5 reasoned before answering on 41.2% of DDXPlus cases (median 0 reasoning tokens; interquartile range 0 to 197) and on 10 of 45 Semigran cases.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    All three models were more accurate on the 5-descriptor version of each ophthalmic complaint than on the 3-descriptor version (Jev 82.5% vs 95.0%, P=.13; Opus 5 82.5% vs 100%, P=.02; Opus 5.5 80.0% vs 97.5%, P=.02).

    “All three models were more accurate on the 5-descriptor version of each complaint than on the 3descriptor version (Figure 3): Jev 82.5% vs 95.0% (P=.13),Opus 5 82.5% vs 100% (P=.02), and Opus 5.5 80.0% vs 97.5% (P=.02).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Jev's misses on ophthalmic complaints were harder misses: the true diagnosis fell outside its top 3 in 8.8% of cases (vs 3.8% and 2.5%), and it assigned exactly zero to the true diagnosis twice.

    “Its misses were harder misses: the true diagnosis fell outside its top 3 in 8.8% of cases (vs 3.8% and 2.5%), and it assigned exactly zero to the true diagnosis twice.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Given each option list with no patient information, Jev concentrated its probability on one diagnosis: viral upper respiratory illness at 95.6% for the Semigran list, upper respiratory tract infection at 63.4% for DDXPlus, and floaters at 32.4% for the ophthalmic list.

    “Given each option list with no patient information, Jev concentrated its probability on one diagnosis (Figure 2): viral upper respiratory illness at 95.6% for the Semigran list, upper respiratory tract infection at 63.4% for DDXPlus, and floaters at 32.4% for the ophthalmic list.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Across all outputs, 92.0% of Jev's probabilities were exactly zero and 98.8% fell on a 0.01 grid.

    “Across all outputs, 92.0% of Jev's probabilities were exactly zero and 98.8% fell on a 0.01 grid.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductreasoning

    Registered primary hypothesis H3 (irrelevant options) and secondary hypothesis H2 (paraphrases) were not run, because clinician-confirmed distractors and paraphrases were not prepared.

    “Registered primary hypothesis H3 (irrelevant options) and secondary hypothesis H2 (paraphrases) were not run, because clinician-confirmed distractors and paraphrases were not prepared.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductnone given

    The registered primary outcomes were order invariance, independence from irrelevant options, and calibration.

    “The registered primary outcomes were order invariance, independence from irrelevant options, and calibration.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductown data

    A sampled-answer arm for Opus 5.5 was dropped because its failures arose from reasoning exhausting a 50-token limit, and successful cases returned the same answer on all 20 samples.

    “A sampled-answer arm for Opus 5.5 was dropped: its failures arose from reasoning exhausting a 50-token limit, and successful cases returned the same answer on all 20 samples.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationown data

    Our Semigran results agree with earlier vignette studies, and the set was too small and too easy to separate the models.

    “our Semigran results agree, and the set was too small and too easy to separate the models.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    Prior independent tests of Jev on non-clinical tasks reported nondeterminism, overconfidence on some question types, and above-chance accuracy from answer options alone.

    “In the two weeks after release, independent developers tested Jev on customer-support routing, phishing detection, and licensing-exam questions, reporting nondeterminism, overconfidence on some question types, and above-chance accuracy from the answer options alone [7][8][9].”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [7] jujumilk3. jev-calibration-audit: independent API-only calibration audit of TypeSafe AI’s Jev decision model. GitHub. 2026. https://github.com/jujumilk3/jev-calibration-audit

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [8] TypeSafe’s Jev scores 62.6% asked once and 95% split five ways (pre-registered non-clinical evaluation). 2026. https://www.beri.net/article/typesafe-jev-typed-decision-model-calibration-decomposition-shadow-eval

      Not checked in the free run.

    • cites [9] Open Medical Jev: frozen open models on national medical licensing exams (GitHub, FeiLiuEM/open-medical-jev). 2026. https://github.com/FeiLiuEM/open-medical-jev

      Not checked in the free run.

  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductcitation

    Calibration was measured by expected calibration error (10 equal-width bins on top-1 confidence), multiclass Brier score, and log-loss after mixing each distribution with 1% uniform mass.

    “Calibration was measured by expected calibration error (10 equal-width bins on top-1 confidence) [15], multiclass Brier score, and log-loss after mixing each distribution with 1% uniform mass (so that exact zeros are scored identically for every model).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [15] 2017

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Two amendments made before any study data (scoring of log-loss, choice of Semigran input text) are included in the registration.

    “Two amendments made before any study data (scoring of log-loss, choice of Semigran input text) are included in the registration.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Every response was stored with its timestamp, the provider's resolved model version, and the code version that produced it.

    “Every response was stored with its timestamp, the provider's resolved model version, and the code version that produced it.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    The registered rule that Claude answer without reasoning could not be met for Opus 5.5, which does not allow reasoning to be disabled.

    “The registered rule that Claude answer without reasoning could not be met for Opus 5.5, which does not allow reasoning to be disabled.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Registered hypotheses on irrelevant options and paraphrases were not run.

    “Registered hypotheses on irrelevant options and paraphrases were not run.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductnone given

    An analysis error that counted the options-only calls as one extra case in paired comparisons was found and corrected before the results reported here; per-model accuracy and calibration were not affected.

    “An analysis error that counted the options-only calls as one extra case in paired comparisons was found and corrected before the results reported here; per-model accuracy and calibration were not affected.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    All random orders used a fixed seed.

    “All random orders used a fixed seed.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductnone given

    All three models are commercial products that change; our results describe the versions tested.

    “Finally, all three models are commercial products that change; our results describe the versions tested.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductnone given

    Each case was presented as a single message, whereas real triage is a conversation in which the clinician asks follow-up questions.

    “And each case was presented as a single message, whereas real triage is a conversation in which the clinician asks follow-up questions.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    Jev 1.13 is a decision model that generates no text and returns a probability for every option in one pass.

    “Jev 1.13 (TypeSafe AI, released September 2026) generates no text: given a case and a list of options, it returns a probability for every option in one pass, at a small fraction of an LLM's cost and latency.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [4] TypeSafe AI. Jev on OpenRouter (documentation). 2026. https://openrouter.ai/docs/guides/community/jev.md

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.

    Study design and conductnone given

    All code, data manifests, and results are version-controlled, and every result row records the commit that produced it.

    “All code, data manifests, and results are version-controlled, and every result row records the commit that produced it.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Study design and conductnone given

    Holm correction was applied across the registered primary comparisons.

    “Holm correction was applied across the registered primary comparisons.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    On DDXPlus, Jev was overconfident while Opus 5.5 was underconfident; at similar calibration error, Jev's pattern is the more dangerous for triage, because underconfidence produces unnecessary referrals rather than missed ones.

    “On DDXPlus, Jev was overconfident while Opus 5.5 was underconfident; at similar calibration error, Jev's pattern is the more dangerous for triage, because underconfidence produces unnecessary referrals rather than missed ones.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductnone given

    Jev cannot ask for clarification, and we did not test whether the language models' ability to do so would change their accuracy.

    “Jev cannot ask for clarification, and we did not test whether the language models' ability to do so would change their accuracy.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationown data

    Its probabilities expressed uncertainty only when the question allowed abstention, and it assigned high confidence to option lists with no case attached.

    “Its probabilities expressed uncertainty only when the question allowed abstention, and it assigned high confidence to option lists with no case attached.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductnone given

    Paired comparisons between models used exact McNemar tests for binary outcomes and case-level bootstrap intervals for continuous ones.

    “Paired comparisons between models used exact McNemar tests for binary outcomes and case-level bootstrap intervals (10,000 resamples; 2,000 for calibration error) for continuous ones.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim.

    Study design and conductcitation

    The analysis plan, hypotheses, and violation thresholds were fixed before data collection.

    “The analysis plan, hypotheses, and violation thresholds were fixed before data collection and registered on the Open Science Framework (osf.io/fpmg3)[10] on 26 September 2026, before the first study model call.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [10] Deobhakta A. Pre-registration: probabilistic coherence and calibration of a System One decision model (Jev) vs Claude Opus on clinical diagnosis. Open Science Framework. 2026. https://osf.io/fpmg3

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Classified as probably not a substantial claim.

    Study design and conductcitation

    The study was pre-registered on OSF on 26 September 2026 before the first study model call.

    “The analysis plan, hypotheses, and violation thresholds were fixed before data collection and registered on the Open Science Framework (osf.io/fpmg3)[10] on 26 September 2026, before the first study model call.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [10] Deobhakta A. Pre-registration: probabilistic coherence and calibration of a System One decision model (Jev) vs Claude Opus on clinical diagnosis. Open Science Framework. 2026. https://osf.io/fpmg3

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

  • Classified as probably not a substantial claim. May combine two claims.

    Premisecitation

    The developer markets Jev's probabilities as calibrated, the product of a training method aimed at calibration rather than fluent text.

    “Its developer markets these probabilities as calibrated, the product of a training method aimed at calibration rather than fluent text [4].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [4] TypeSafe AI. Jev on OpenRouter (documentation). 2026. https://openrouter.ai/docs/guides/community/jev.md

      Not checked in the free run.

  • May combine two claims.

    Interpretationown data

    In this pre-registered evaluation, a decision model marketed as calibrated matched frontier language models on short ophthalmic complaints, with better calibration than the registered comparator, but was substantially less accurate on multi-symptom synthetic patients, where it excluded the correct diagnosis outright in about 6% of cases.

    “In this pre-registered evaluation, a decision model marketed as calibrated matched frontier language models on short ophthalmic complaints, with better calibration than the registered comparator, but was substantially less accurate on multi-symptom synthetic patients, where it excluded the correct diagnosis outright in about 6% of cases.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductnone given

    All cases were written, not spoken, and none came from real patients; DDXPlus patients are synthetic, and our rendering of their structured findings is stilted.

    “All cases were written, not spoken, and none came from real patients; DDXPlus patients are synthetic, and our rendering of their structured findings is stilted.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationown data

    On short, distinctive ophthalmic complaints, Jev was as accurate as two frontier language models and better calibrated than the registered comparator.

    “On short, distinctive ophthalmic complaints, Jev was as accurate as two frontier language models and better calibrated than the registered comparator.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationown data

    Our results confirm run-to-run variation in a clinical setting (a third of repeated outputs differed) and show that option-list structure drives answers when the input is uninformative.

    “Our results confirm run-to-run variation in a clinical setting (a third of repeated outputs differed) and show that option-list structure drives answers when the input is uninformative.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationown data

    The model can recognize an uninformative input, but its probabilities carry that signal only when the question allows it.

    “The model can recognize an uninformative input, but its probabilities carry that signal only when the question allows it.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductnone given

    The ophthalmic set comprised 80 simulated complaints, a small sample of uncertain applicability to real patient calls.

    “The ophthalmic set comprised 80 simulated complaints, a small sample of uncertain applicability to real patient calls”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Opus 5.5's resolved version carried no dated snapshot identifier.

    “Opus 5.5's resolved version carried no dated snapshot identifier.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    None of the prior independent tests of Jev tested clinical diagnosis against a pre-specified plan, compared the model with frontier LLMs with reasoning both on and off, or examined how its probabilities fail.

    “None of this work tested clinical diagnosis against a pre-specified plan, compared the model with frontier LLMs with reasoning both on and off, or examined how its probabilities fail.”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [7] jujumilk3. jev-calibration-audit: independent API-only calibration audit of TypeSafe AI’s Jev decision model. GitHub. 2026. https://github.com/jujumilk3/jev-calibration-audit

      Couldn’t be matched to a paper in Crossref, so it can’t be checked.

    • cites [8] TypeSafe’s Jev scores 62.6% asked once and 95% split five ways (pre-registered non-clinical evaluation). 2026. https://www.beri.net/article/typesafe-jev-typed-decision-model-calibration-decomposition-shadow-eval

      Not checked in the free run.

    • cites [9] Open Medical Jev: frozen open models on national medical licensing exams (GitHub, FeiLiuEM/open-medical-jev). 2026. https://github.com/FeiLiuEM/open-medical-jev

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    A tie-breaking error that could register spurious top-1 changes under reordering was corrected before final analysis.

    “A tie-breaking error that could register spurious top-1 changes under reordering was corrected before final analysis.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).

    Study design and conductnone given

    Jev's 0.01 output resolution makes its noise and distance measures coarser than the comparators'.

    “Jev's 0.01 output resolution makes its noise and distance measures coarser than the comparators'.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    The registered order-sensitivity criterion compared the largest of five permutation distances with a single-pair noise threshold, which flags about 23% of cases from noise alone.

    “The registered order-sensitivity criterion compared the largest of five permutation distances with a single-pair noise threshold, which flags about 23% of cases from noise alone.”
    Quote in the paperNot a substantial claim
52 of 52

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

  • Lyons citation points to a nonexistent reference number

    Minor

    The text cites Lyons as reference [16], but the Lyons entry is numbered 15; there is no reference 16 in the list.

  • DDXPlus calibration error was numerically worse for Jev

    Minor

    Opus 5.5 was the registered comparator. On DDXPlus, Jev's expected calibration error was 0.116 versus 0.109 for Opus 5.5, so it was numerically worse on one of the three sets, even though the difference was not statistically significant.

2 of 2

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. 2017, Proceedings of the 34th International Conference on Machine Learning, 70, 1321

Cited by

Still being checked.

Authors
Deobhakta, A., Chang, J., Chen, R. W. S., Jaipalli, S., Pinhas, A., Tania Tai, T. Y., & Rosen, R. B.
Affiliations
  • New York Eye and Ear Infirmary (US)
  • University of Wisconsin–Madison (US)
  • Columbia University Irving Medical Center (US)
  • Icahn School of Medicine at Mount Sinai (US)
  • New York Eye and Ear Infirmary of Mount Sinai, New York, NY, USA
Corresponding author
Deobhakta, Avnish
Venue
medRxiv
Publisher
openRxiv
Published
2026-10-11
OpenAlex
W7221453278
Cited by
0
References
9
Type
posted content
Language
en
Open access
Locations
medRxiv (acceptedVersion, cc-by)
Topics
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Family Practice › Clinical Reasoning and Diagnostic Skills
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
Keywords
Jev, language models, Claude Opus, diagnosis, diagnostic accuracy, probability calibration, expected calibration error, Brier score, differential diagnosis, clinical triage, pre-registered evaluation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-11-03.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-11-03.

Cited sources are checked by gpt-6-sol.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review