The Accuracy of Pedometers in Measuring Walking Steps on a Treadmill in College Students
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Pedometers are a popular way for people to track if they have reached the recommended 10,000 daily steps. Therefore, the purpose of this study was to determine the accuracy of four brands of pedometers at measuring steps, and to determine if a relationship exists between pedometer cost and accuracy. The hypothesis was that the more expensive brands of pedometers (the Fitbit Charge™ and Omron HJ-303™) would yield more accurate step counts than less expensive brands (the SmartHealth - Walking FIT™ and Sportline™). While wearing all pedometers at once, one male and eleven female college students (mean ± SD; age = 20.8 ± 0.94 years) walked 400 meters on a treadmill for 5 minutes at 3.5 miles per hour. The pedometer step counts were recorded at the end. Video analysis of the participants' feet was later completed to count the number of steps actually taken (actual steps). When compared to the actual steps, the Sportline™ brand (-3.83 ± 22.05) was the only pedometer that was significantly similar. The other three brands significantly under-estimated steps (Fitbit™ 55.00 ± 42.58, SmartHealth™ 43.50 ± 49.71, and Omron™ 28.58 ± 33.86), with the Fitbit being the least accurate. These results suggest an inverse relationship between cost and accuracy for the four specific brands tested, and that waist pedometers are more accurate than wrist pedometers. The results concerning the Fitbit are striking considering its high cost and popularity among consumers today. Further research should be conducted to improve the accuracy of pedometers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“[45-56] Wrist Discontinued 2014 Charge Fitbit”
Review on Wearable Technology Sensors Used in Consumer Sport Applications
Aroganam, G., Manivannan, N., & Harrison, D. (2019) · Sensors · doi:10.3390/s19091983 · Cited by 370
Shin, G., Jarrahi, M. H., Fei, Y., Karami, A., Gafinowitz, N., Byun, A., & Lu, X. (2019) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2019.103153 · Cited by 326
Degroote, L., Hamerlinck, G., Poels, K., Maher, C., Crombez, G., De Bourdeaudhuij, I., Vandendriessche, A., Curtis, R. G., & DeSmet, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/16674 · Cited by 60
“an accompanying app and are considered less usable by people than activity trackers [72-74].”
BackgroundAlbergoni, A., Hettinga, F. J., La Torre, A., Bonato, M., & Sartor, F. (2019) · Sports Medicine - Open · doi:10.1186/s40798-019-0214-z · Cited by 39
“However, it needs to be acknowledged that the accuracy of step counting at lower speeds has been found to be reduced [66, 67].”
Background
Metadata
- Authors
- Husted, H. M., & Llewellyn, T.
- Venue
- International Journal of Exercise Science
- Published
- 2017
- Volume
- 10
- Issue
- 1
- Pages
- 146-153
- ISSN
- 1939-795X (ISSN-L)
- OpenAlex
- W2594485094
- Cited by
- 31
- References
- 2
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.